The test case rpl_do_grant fails sporadically on PB2 with "Access
denied for user 'create_rout_db'@'localhost' ...". Inspecting the
test case, one may find that if issues a GRANT on the master
connection and immediately after it creates two new connections
(one to the master and one to the slave) using the credentials
set with the GRANT.
Unfortunately, there is no synchronization between master and
slave after the grant and before the connections are
established. This can result in slave not having executed the
GRANT by the time the connection is attempted.
This patch fixes this by deploying a sync_slave_with_master
between the grant and the connections attempt.
The test case creates two temporary tables, then closes the
connection, waits for it to disconnect, then syncs the slave with
the master, checks for remaining opened temporary tables on
slave (which should be 0) and finally drops the used
database (mysqltest).
Unfortunately, sometimes, the test fails with one open table on
the slave. This seems to be caused by the fact that waiting for
the connection to be closed is not sufficient. The test needs to
wait for the DROP event to be logged and only then synchronize
the slave with the master and proceed with the check. This is
caused by the asynchronous nature of the disconnect wrt
binlogging of the DROP temporary table statement.
We fix this by deploying a call to wait_for_binlog_event.inc
on the test case, which makes execution to wait for the DROP
temp tables event before synchronizing master and slave.
Problem: LOGGER::general_log_write() relied on valid "thd" parameter passed
but had inconsistent "if (thd)" check.
Fix: as we always pass a valid "thd" parameter to the method,
redundant check removed.
The problem is that argument buffer can be used as result buffer
and it leads to argument value change.
The fix is to use 'old buffer' as result buffer only
if first argument is not constant item.
In RBR, There is an inconsistency between slaves and master.
When INSERT statement which includes an auto_increment field is executed,
Store engine of master will check the value of the auto_increment field.
It will generate a sequence number and then replace the value, if its value is NULL or empty.
if the field's value is 0, the store engine will do like encountering the NULL values
unless NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
In contrast, if the field's value is 0, Store engine of slave always generates a new sequence number
whether or not NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
SQL MODE of slave sql thread is always consistency with master's.
Another variable is related to this bug.
If generateing a sequence number is decided by the values of
table->auto_increment_field_not_null and SQL_MODE(if includes MODE_NO_AUTO_VALUE_ON_ZERO)
The table->auto_increment_is_not_null is FALSE, which causes this bug to appear. ..
Archive engine returns wrong values for average record length
and max data length.
With this fix they're calculated as following:
- max data length is 2 ^ 63 where large files are supported
and INT_MAX32 where this is not supported;
- average record length is data length / records in data file.
Create temporary InnoDB table fails on case insensitive
filesystems, when lower_case_table_names is 2 (e.g. OS X)
and temporary directory path contains upper case letters.
The problem was that tmpdir prefix was converted to lower
case when table was created, but was passed as is when
table was opened.
Fixed by leaving tmpdir prefix part intact.
The parser rule for expressions in a udf parameter list contains
two hacks:
First, the parser input stream is read verbatim, bypassing
the lexer.
Second, the Item::name field is overwritten. If the argument to a
udf was a field, the field's name as seen by name resolution was
overwritten this way.
If the field name was quoted or escaped, it would appear as e.g. "`field`".
Fixed by not overwriting field names.
This test case uses mysqlbinlog to dump the content of master-bin.000001,
but the content of master-bin.000001 is not that this test needs.
MTR runs a lot of test cases on one server, so when this test starts, the current binlog file
might not be master-bin.000001, or there are other events are written by tests before.
'RESET MASTER' command must be called at the begin, it ensures that binlog of this test
is wrote to master-bin.000001 correctly.
Three other tests have the same problem, They were fixed together.
mysqlbinlog-cp932
binlog_incident
binlog_tmp_table
Postfix.
extra/rpl_tests/rpl_row_sp006.test had changed to fix this bug.
extra/rpl_tests/rpl_row_sp006.test is also referenced by rpl_ndb_sp006,
So rpl_row_sp006.result must be changed too.
The external 'for' loop in remove_dup_with_compare() handled
HA_ERR_RECORD_DELETED by just starting over without advancing
to the next record which caused an infinite loop.
This condition could be triggered on certain data by a SELECT
query containing DISTINCT, GROUP BY and HAVING clauses.
Fixed remove_dup_with_compare() so that we always advance to
the next record when receiving HA_ERR_RECORD_DELETED from
rnd_next().
(Backport)
Problem is that when insert (ha_start_bulk_insert) in i partitioned table,
it will call ha_start_bulk_insert for every partition, used or not.
Solution is to delay the call to the partitions ha_start_bulk_insert until
the first row is to be inserted into that partition
on subquery inside a SP
Problem: repeated call of a SP containing an incorrect query with a
subselect may lead to failed ASSERT().
Fix: set proper sublelect's state in case of error occured during
subquery transformation.
SELECT with join (not only self-join) from archive table may
return incomplete result set, when result set size exceeds
join buffer size.
The problem was that archive row counter was initialzed too
early, when ha_archive::info() method was called. Later,
when optimizer exceeds join buffer, it attempts to reuse
handler without calling ha_archive::info() again (which is
correct).
Fixed by moving row counter initialization from
ha_archive::info() to ha_archive::rnd_init().
name as existing view
When trying to create a table with the same name as existing view with
join, mysql server crashes.
The problem is when create table is issued with the same name as view, while
verifying with the existing tables, we assume that base table object is
created always.
In this case, since it is a view over multiple tables, we don't have the
mysql derived table object.
Fixed the logic which checks if there is an existing table to not to assume
that table object is created when the base table is view over multiple
tables.
Inserting a negative value in the autoincrement column of a
partitioned innodb table was causing the value of the auto
increment counter to wrap around into a very large positive
value. The consequences are the same as if a very large positive
value was inserted into a column, e.g. reduced autoincrement
range, failure to read autoincrement counter.
The current patch ensures that before calculating the next
auto increment value, the current value is within the positive
maximum allowed limit.
Essentially, Bug#45574 results in this bug. The 'CREATE DATABASE IF NOT EXISTS' statement was not
binlogged, when the database has existed.
Sometimes, the master and slaves become inconsistent. The "CREATE DATABASE
IF NOT EXISTS mysqltest1" statement is not binlogged
if the db 'mysqltest1' existed before the test case is executed.
So the db 'mysqltest1' can't be created on slave.
Patch of Bug#45574 has resolved this problem.
But I think it is better to replace 'mysqltest1' by default db 'test'.
myisamchk tool generates warnings when run on an myisam files (.MYI or .MYD)
This is because of the conversion of max_value for certain options in myisamchk
from singed long to unsigned long
The max value for the options key_buffer_size, read_buffer_size, write_buffer
_size and sort_buffer_size is given as (long) ~0L which becomes -1 when casted
from signed long to longlong and then casted to ulonglong. When (ulonglong) -1
is compared with maximal value for GET_ULONG data type, we adjust it to
(ulonglong) ULONG_MAX and throw the warning.
Fixed by using the right max size.
Max values for the variables (from mysqld.cc)
----------------------------
1. key_buffer_size
5.0: ULONG_MAX
5.1: SIZE_T_MAX
6.0: SIZE_T_MAX
2. read_buffer_size and write_buffer_size
5.0: INT_MAX32
5.1: INT_MAX32
6.0: INT_MAX32
3. sort_buffer_size (aka myisam_sort_buffer_size)
5.0: UINT_MAX32
5.1: ULONG_MAX
6.0: ULONG_MAX
Note: testcase not attached
function,file sql_base.cc
When uncacheable queries are written to a temp table the optimizer must
preserve the original JOIN structure, because it is re-using the JOIN
structure to read from the resulting temporary table.
This was done only for uncacheable sub-queries.
But top level queries can also benefit from this mechanism, specially if
they're using index access and need a reset.
Fixed by not limiting the saving of JOIN structure to subqueries
exclusively.
Added a new test file to extend the existing (large) subquery.test.
CREATE TABLE...LIKE...
The mysql server option 'sync_frm' is ignored when table is created with
syntax CREATE TABLE .. LIKE..
Fixed by adding the MY_SYNC flag and calling my_sync() from my_copy() when
the flag is set.
In mysql_create_table(), when the 'sync_frm' is set, MY_SYNC flag is passed
to my_copy().
Note: TestCase is not attached and can be tested manually using debugger.