depends on uninitialised value
Initialized THD::force_read_stats introduced in the patch for MDEV-17605.
Leaving this field uninitialized in the constructor of the THD class may
trigger reading statistical data that is not needed.
Item_func_min_max::fix_length_and_dec() erroneously set max_length
to UINT32_MAX.
Merge notes:
In 10.3 this problem had been fixed earlier.
During merge to 10.3, do a "null merge" in item_func.cc
commit ac275d0b4ad (connect/10.0)
Author: Olivier Bertrand <bertrandop@gmail.com>
Date: Wed Mar 27 12:46:20 2019 +0100
Comment out unrecognized command line options: Modified CMakeLists.txt
commit 592f1f75ad6
Author: Olivier Bertrand <bertrandop@gmail.com>
Date: Tue Mar 26 19:52:33 2019 +0100
Replace Command not recognized by CMake modified: CMakeLists.txt
commit 00f72199b16
Author: Olivier Bertrand <bertrandop@gmail.com>
Date: Tue Mar 26 18:15:08 2019 +0100
- Fix MDEV-15793: Server crash in PlugCloseFile with sql_mode=''
Fixed by replacing sprinf by snprintf in ShowValue to avoid
buffer overflow. It nows always use a buffer and returns int.
modified: storage/connect/tabdos.cpp
modified: storage/connect/tabfmt.cpp
modified: storage/connect/value.cpp
modified: storage/connect/value.h
- Fix MDEV-18292: CONNECT Engine JDBC not able to issue
simple UPDATE statement from trigger or stored procedure
Was not fixed when the same table was called several times
with different modes. Fixed by checking if a new statement
is compatible in the start_stmt function. It nows do the
same checks than external_lock.
modified: storage/connect/ha_connect.cc
modified: storage/connect/ha_connect.h
- typo
modified: storage/connect/user_connect.cc
- Fix GetTableName that returned wrong value under Windows
modified: storage/connect/ha_connect.cc
- Fix MDEV-13136: enhance CREATE SERVER MyServerName
FOREIGN DATA WRAPPER to work with CONNECT engine
modified: storage/connect/tabjdbc.cpp
- Add a function to retrieve User variable value (DEVELOPMENT only)
modified: storage/connect/ha_connect.cc
modified: storage/connect/jsonudf.cpp
modified: storage/connect/jsonudf.h
modified: storage/connect/tabjdbc.cpp
- Fix MDEV-18192: CONNECT Engine JDBC not able to issue
simple UPDATE statement from trigger or stored procedure
modified: storage/connect/tabext.cpp
modified: storage/connect/tabext.h
modified: storage/connect/tabjdbc.cpp
- Enable CONNECT tables to have triggers
Update version number
modified: storage/connect/ha_connect.cc
- Make user and password defined in CREATE TABLE have precedence on
the ones specified in a Federated Server.
modified: storage/connect/tabjdbc.cpp
- JSONColumns: Copy locally constant strings to fix error in OEM modules
modified: storage/connect/tabjson.cpp
commit 99de7f4e486
Author: Olivier Bertrand <bertrandop@gmail.com>
Date: Sun Jan 27 15:16:15 2019 +0100
- Fix MDEV-18192: CONNECT Engine JDBC not able to issue
simple UPDATE statement from trigger or stored procedure
modified: storage/connect/tabext.cpp
modified: storage/connect/tabext.h
modified: storage/connect/tabjdbc.cpp
- Enable CONNECT tables to have triggers
Update version number
modified: storage/connect/ha_connect.cc
- Make user and password defined in CREATE TABLE have precedence on
the ones specified in a Federated Server.
modified: storage/connect/tabjdbc.cpp
- JSONColumns: Copy locally constant strings to fix error in OEM modules
modified: storage/connect/tabjson.cpp
Before killing the server, we must issue FLUSH TABLES in order
to cleanly close any MyISAM system tables, to avoid warnings about
them when restarting.
For partitioned table, ensure that the AUTO_INCREMENT values will
be assigned from the same sequence. This is based on the following
change in MySQL 5.6.44:
commit aaba359c13d9200747a609730dafafc3b63cd4d6
Author: Rahul Malik <rahul.m.malik@oracle.com>
Date: Mon Feb 4 13:31:41 2019 +0530
Bug#28573894 ALTER PARTITIONED TABLE ADD AUTO_INCREMENT DIFF RESULT DEPENDING ON ALGORITHM
Problem:
When a partition table is in-place altered to add an auto-increment column,
then its values are starting over for each partition.
Analysis:
In the case of in-place alter, InnoDB is creating a new sequence object
for each partition. It is default initialized. So auto-increment columns
start over for each partition.
Fix:
Assign old sequence of the partition to the sequence of next partition
so it won't start over.
RB#21148
Reviewed by Bin Su <bin.x.su@oracle.com>
Correctly document the usage of m_max_value. Remove the const
qualifier, so that the implicit assignment operator can be used.
Make all members of ib_sequence private, and add an accessor
member function max_value().
PROBLEM
=======
An add index doesn't update index length stats in information schema
TABLES table.
FIX
===
Update the dict_table_t variable with index length stats that is
actually calculated post alter . As this variable is used to populated
the information schema index length statistics.
Reviewed by: Bin su<bin.x.su@oracle.com>
RB: 21277
Field_bit for BIT(20) uses 2 full bytes in the record,
with additional 4 uneven bits in the "null bit area".
Field::set_default() called from Field_bit::set_default() erroneously
copied 3 bytes instead of 2 bytes from the record with default values.
Changing Field::set_default() to copy pack_length_in_rec() bytes
instead of pack_length() bytes.
In debug builds, this setting is allowed to be turned off temporarily after it was
turned on during startup. Howewer memory garbage also caused it to be accidentally
turned on when it was disabled at startup.
group concat tree is allocated in a memroot, so the only way to free
memory is to copy a part of the tree into a new memroot.
track the accumilated length of the result, and when it crosses
the threshold - copy the result into a new tree, free the old one.
This patch fixes an invalid read in fill_effective_table_privileges
triggered by a grant_version increase between a PREPARE for a
statement creating a view from I_S and EXECUTE.
A tmp table was created and free'd while preparing the statement,
TABLE_LIST::table_name was set to point to the tmp table
TABLE_SHARE::table_name which no longer existed after preparing was
done.
The grant version increase made fill_effective_table_privileges
called during EXECUTE to try fetch the updated grant info and
this is where the dangling table name was used.
triggers are opened and tables used in triggers are prelocked in
open_tables(). But multi-update can detect what tables will actually
be updated only later, after all main tables are opened.
Meaning, if a table is used in multi-update, but is not actually updated,
its on-update treggers will be opened and tables will be prelocked,
even if it's unnecessary. This can cause more tables to be
write-locked than needed, causing read_only errors, privilege errors
and lock waits.
Fix: don't open/prelock triggers unless table->updating is true.
In multi-update after setting table->updating=true, do a second
open_tables() for newly added tables, if any.
it always required UPDATE privilege on views, not being able to detect
when a views was not actually updated in multi-update.
fix: instead of marking all tables as "updating" by default,
only set "updating" on tables that will actually be updated
by multi-update. And mark the view "updating" if any of the
view's tables is.