View definition as SELECT ... FROM DUAL WHERE ... has
valid syntax, but use of such view in SELECT or
SHOW CREATE VIEW syntax causes unexpected syntax error.
Server omits FROM DUAL clause when storing view body
string in a .frm file for further evaluation.
However, syntax of SELECT-witout-FROM query is more
restrictive than SELECT FROM DUAL syntax, and doesn't
allow the WHERE clause.
NOTE: this syntax difference is not documented.
View registration procedure has been modified to
preserve original structure of view's body.
localhost/default port
When creating federated table that points to unspecified host or
localhost on unspecified port or port is 0, small memory leak occurs.
This happens because we make a copy of unix socket path, which is
never freed.
With this fix we do not make a copy of unix socket path, instead
share->socket points to MYSQL_UNIX_ADDR constant directly.
This fix is covered by a test case for BUG34788.
Affects 5.0 only.
The bool data type was redefined to BOOL (4 bytes on windows).
Removed the #define and fixed some of the warnings that were uncovered
by this.
Note that the fix also disables 2 warnings :
4800 : 'type' : forcing value to bool 'true' or 'false' (performance warning)
4805: 'operation' : unsafe mix of type 'type' and type 'type' in operation
These warnings will be handled in a separate bug, as they are performance related or bogus.
Fixed to int the return type of functions that return more than
2 distinct values.
correctly - crashes server !
Creating federated table with connect string containing empty
(zero-length) host name and port is evaluated as 0 (port is
incorrect, omitted or 0) crashes server.
This happens because federated calls strcmp() with NULL pointer.
Fixed by avoiding strcmp() call if hostname is set to NULL.
isn't running
Pass the process id of the manager as a parameter to "wait_for_pid"
and if the manager isn't running, then do not continue to wait.
Also, capture the error message of our process-existence test,
"kill -0", as we expect errors and shouldn't pass them to the user.
Additionally, be a bit more descriptive of what the problem is.
The problem is that unimplemented WIN32 version of pthread_kill
is returning ESRCH no matter the arguments, causing calls to
mysqld_list_processes to set the procinfo to dead because
pthread_kill returns non zero. The dead procinfo would show
up on a second invocation of show processlist.
binlogging of insert into a autoincrement blackhole table ignored
an explicit set insert_id.
Fixed with refining of the blackhole's insert method to call
update_auto_increment() that prepares binlogging the insert query
with the preceeding set insert_id.
Note, as the engine does not store any actual data one has to explicitly
provide to the server with the value of the autoincrement column via
set insert_id. Otherwise binlogging will happend with the default
set insert_id=1.
When swapping out heap I_S tables to disk, this is done after plan refinement.
Thus, READ_RECORD::file will still point to the (deleted) heap handler at start
of execution. This causes segmentation fault if join buffering is used and the
query is a star query where the result is found to be empty before accessing
some table. In this case that table has not been initialized (i.e. had its
READ_RECORD re-initialized) before the cleanup routine tries to close the handler.
Fixed by updating READ_RECORD::file when changing handler.