Despite copying the value of the old table's row type
we don't always have to mark row type as being specified.
Innodb uses this to check if it can do fast ALTER TABLE
or not.
Fixed by correctly flagging the presence of row_type
only when it's actually changed.
Added a test case for 39200.
But there is no Last_IO_Error reported.
On the master, if a binary log event is larger than max_allowed_packet,
ER_MASTER_FATAL_ERROR_READING_BINLOG and the specific reason of this error is
sent to a slave when it requests a dump from the master, thus leading
the I/O thread to stop.
On a slave, the I/O thread stops when receiving a packet larger than max_allowed_packet.
In both cases, however, there was no Last_IO_Error reported.
This patch adds code to report the Last_IO_Error and exact reason before stopping the
I/O thread and also reports the case the out memory pops up while
handling packets from the master.
When parsing the service installation parameter in
default_service_handling() make sure the value of the
optional parameter doesn't overwrite it's name.
1. Fixes BUG#44030 - Error: (1500) Couldn't read the MAX(ID) autoinc value
from the index (PRIMARY)
2. Disables the innodb-autoinc test for innodb plugin temporarily.
The testcase for this bug has different result file for InnoDB plugin.
Should add the testcase to Innodb suite with a different result file.
Detailed revision comments:
r5243 | sunny | 2009-06-04 03:17:14 +0300 (Thu, 04 Jun 2009) | 14 lines
branches/5.1: When the InnoDB and MySQL data dictionaries go out of sync, before
the bug fix we would assert on missing autoinc columns. With this fix we allow
MySQL to open the table but set the next autoinc value for the column to the
MAX value. This effectively disables the next value generation. INSERTs will
fail with a generic AUTOINC failure. However, the user should be able to
read/dump the table, set the column values explicitly, use ALTER TABLE to
set the next autoinc value and/or sync the two data dictionaries to resume
normal operations.
Fix Bug#44030 Error: (1500) Couldn't read the MAX(ID) autoinc value from the
index (PRIMARY)
rb://118
r5252 | sunny | 2009-06-04 10:16:24 +0300 (Thu, 04 Jun 2009) | 2 lines
branches/5.1: The version of the result file checked in was broken in r5243.
r5259 | vasil | 2009-06-05 10:29:16 +0300 (Fri, 05 Jun 2009) | 7 lines
branches/5.1:
Remove the word "Error" from the printout because the mysqltest suite
interprets it as an error and thus the innodb-autoinc test fails.
Approved by: Sunny (via IM)
r5466 | vasil | 2009-07-02 10:46:45 +0300 (Thu, 02 Jul 2009) | 6 lines
branches/5.1:
Adjust the failing innodb-autoinc test to conform to the latest behavior
of the MySQL code. The idea and the comment in innodb-autoinc.test come
from Sunny.
The test case rpl_do_grant fails sporadically on PB2 with "Access
denied for user 'create_rout_db'@'localhost' ...". Inspecting the
test case, one may find that if issues a GRANT on the master
connection and immediately after it creates two new connections
(one to the master and one to the slave) using the credentials
set with the GRANT.
Unfortunately, there is no synchronization between master and
slave after the grant and before the connections are
established. This can result in slave not having executed the
GRANT by the time the connection is attempted.
This patch fixes this by deploying a sync_slave_with_master
between the grant and the connections attempt.
The test case creates two temporary tables, then closes the
connection, waits for it to disconnect, then syncs the slave with
the master, checks for remaining opened temporary tables on
slave (which should be 0) and finally drops the used
database (mysqltest).
Unfortunately, sometimes, the test fails with one open table on
the slave. This seems to be caused by the fact that waiting for
the connection to be closed is not sufficient. The test needs to
wait for the DROP event to be logged and only then synchronize
the slave with the master and proceed with the check. This is
caused by the asynchronous nature of the disconnect wrt
binlogging of the DROP temporary table statement.
We fix this by deploying a call to wait_for_binlog_event.inc
on the test case, which makes execution to wait for the DROP
temp tables event before synchronizing master and slave.
Problem: LOGGER::general_log_write() relied on valid "thd" parameter passed
but had inconsistent "if (thd)" check.
Fix: as we always pass a valid "thd" parameter to the method,
redundant check removed.
The problem is that argument buffer can be used as result buffer
and it leads to argument value change.
The fix is to use 'old buffer' as result buffer only
if first argument is not constant item.
In RBR, There is an inconsistency between slaves and master.
When INSERT statement which includes an auto_increment field is executed,
Store engine of master will check the value of the auto_increment field.
It will generate a sequence number and then replace the value, if its value is NULL or empty.
if the field's value is 0, the store engine will do like encountering the NULL values
unless NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
In contrast, if the field's value is 0, Store engine of slave always generates a new sequence number
whether or not NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
SQL MODE of slave sql thread is always consistency with master's.
Another variable is related to this bug.
If generateing a sequence number is decided by the values of
table->auto_increment_field_not_null and SQL_MODE(if includes MODE_NO_AUTO_VALUE_ON_ZERO)
The table->auto_increment_is_not_null is FALSE, which causes this bug to appear. ..
can crash under load
Merge from 5.0, after backport from 5.1/5.4 to 5.0.
This makes the fixes for
Bug 44068 (RESTORE can disable the MyISAM Key Cache)
Bug 40944 (Backup: crash after myisampack)
available to 5.1.
Archive engine returns wrong values for average record length
and max data length.
With this fix they're calculated as following:
- max data length is 2 ^ 63 where large files are supported
and INT_MAX32 where this is not supported;
- average record length is data length / records in data file.
Create temporary InnoDB table fails on case insensitive
filesystems, when lower_case_table_names is 2 (e.g. OS X)
and temporary directory path contains upper case letters.
The problem was that tmpdir prefix was converted to lower
case when table was created, but was passed as is when
table was opened.
Fixed by leaving tmpdir prefix part intact.
can crash under load
Backport from 5.1.
Does also include key cache fixes from:
Bug 44068 (RESTORE can disable the MyISAM Key Cache)
Bug 40944 (Backup: crash after myisampack)
The parser rule for expressions in a udf parameter list contains
two hacks:
First, the parser input stream is read verbatim, bypassing
the lexer.
Second, the Item::name field is overwritten. If the argument to a
udf was a field, the field's name as seen by name resolution was
overwritten this way.
If the field name was quoted or escaped, it would appear as e.g. "`field`".
Fixed by not overwriting field names.
This test case uses mysqlbinlog to dump the content of master-bin.000001,
but the content of master-bin.000001 is not that this test needs.
MTR runs a lot of test cases on one server, so when this test starts, the current binlog file
might not be master-bin.000001, or there are other events are written by tests before.
'RESET MASTER' command must be called at the begin, it ensures that binlog of this test
is wrote to master-bin.000001 correctly.
Three other tests have the same problem, They were fixed together.
mysqlbinlog-cp932
binlog_incident
binlog_tmp_table
Postfix.
extra/rpl_tests/rpl_row_sp006.test had changed to fix this bug.
extra/rpl_tests/rpl_row_sp006.test is also referenced by rpl_ndb_sp006,
So rpl_row_sp006.result must be changed too.
The external 'for' loop in remove_dup_with_compare() handled
HA_ERR_RECORD_DELETED by just starting over without advancing
to the next record which caused an infinite loop.
This condition could be triggered on certain data by a SELECT
query containing DISTINCT, GROUP BY and HAVING clauses.
Fixed remove_dup_with_compare() so that we always advance to
the next record when receiving HA_ERR_RECORD_DELETED from
rnd_next().
(Backport)
Problem is that when insert (ha_start_bulk_insert) in i partitioned table,
it will call ha_start_bulk_insert for every partition, used or not.
Solution is to delay the call to the partitions ha_start_bulk_insert until
the first row is to be inserted into that partition
on subquery inside a SP
Problem: repeated call of a SP containing an incorrect query with a
subselect may lead to failed ASSERT().
Fix: set proper sublelect's state in case of error occured during
subquery transformation.