file .\filesort.cc, line 149 (part II)
Problem: the server didn't disregard sort order
for some zero length tuples.
Fix: skip sort order in such a case
(zero length NOT NULL string functions).
In process of record search it is not taken into account
that inital quick->file->ref value could be inapplicable
to range interval. After proper row is found this value is
stored into the record buffer and later the record is
filtered out at condition evaluation stage.
The fix is store a refernce of found row to the handler ref field.
mysql_client_binlog_statement
Problem: server may read from unassigned memory performing
"wrong" BINLOG queries.
Fix: never read from unassigned memory.
The default storage engine is changed from MyISAM to
InnoDB, in all builds except for the embedded server.
In addition, the following system variables are
changed:
* innodb_file_per_table is enabled
* innodb_strict_mode is enabled
* innodb_file_format_name_update is changed
to 'Barracuda'
The test suite is changed so that tests that do not
explicitly include the have_innodb.inc are run with
--default-storage-engine=MyISAM. This is to ease the
transition, so that most regression tests are run
with the same engine as before.
Some tests are disabled for the embedded server
regression test, as the output of certain statements
will be different that for the regular server
(i.e SELECT @@default_storage_engine). This is to
ease transition.
line exceeds the limit
The number and/or names of our files for the main test suite
(contents of "mysql-test/t/") now exceeds the command line
length limit on AIX.
Solve the problem by using separate "cp" commands for the
various file name extensions.
and innodb_file_format_max two system variables. And this also fixes
bug #53654 after 2nd shutdown innodb_file_format_check attains strange
values.
rb://366 approved by Marko
This is the fix for 5.5, where the behaviour on both installation
and upgrade is changed:
On installation, we do not start the server, to allow automated
installs (which happen in some indeterminate machine status).
If the server was stopped when the upgrade begins, we assume the
administrator is taking manual action, so we do not start the (new)
server at the end of the upgrade.
We still install the start/stop script, so it will be started on reboot.
This is the fix for 5.1, where only the behaviour on upgrade is changed:
If the server was stopped when the upgrade begins, we assume the
administrator is taking manual action, so we do not start the (new)
server at the end of the upgrade.
We still install the start/stop script, so it will be started on reboot.
On [Open]Solaris/x86 the FPU was not switched to 64-bit double
precision mode when the server binary was built with Sun
Studio. That caused GIS test failures due to differences in
expected and actual results.