for InnoDB
The class Field_bit_as_char stores the metadata for the
field incorrecly because bytes_in_rec and bit_len are set
to (field_length + 7 ) / 8 and 0 respectively, while
Field_bit has the correct values field_length / 8 and
field_length % 8.
Solved the problem by re-computing the values for the
metadata based on the field_length instead of using the
bytes_in_rec and bit_len variables.
To handle compatibility with old server, a table map
flag was added to indicate that the bit computation is
exact. If the flag is clear, the slave computes the
number of bytes required to store the bit field and
compares that instead, effectively allowing replication
*without conversion* from any field length that require
the same number of bytes to store.
mysql-test/suite/rpl/t/rpl_typeconv_innodb.test:
Adding test to check compatibility for bit field
replication when using InnoDB
sql/field.cc:
Extending compatible_field_size() with flags from
table map to allow fields to check master info.
sql/field.h:
Extending compatible_field_size() with flags from
table map to allow fields to check master info.
sql/log.cc:
Removing table map flags since they are not used
outside table map class.
sql/log_event.cc:
Removing flags parameter from table map constructor
since it is not used and does not have to be exposed.
sql/log_event.h:
Adding flag to denote that bit length for bit field type
is exact and not potentially rounded to even bytes.
sql/rpl_utility.cc:
Adding fields to table_def to store table map flags.
sql/rpl_utility.h:
Removing obsolete comment and adding flags to store
table map flags from master.
The 'rpl_get_master_version_and_clock' test verifies if the slave I/O
thread tries to reconnect to master when it tries to get the values of
the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection.
So the master server is restarted for making the transient network
disconnection. Restarting master server can bring two problems as following:
1. The time out error is encountered sporadically. The slave I/O thread tries
to reconnect master ten times, which is set in my.cnf. So in the test
framework sporadically the slave I/O thread really stoped when it can't
reconnect to master in the ten times successfully before the master starts,
then the time out error will be encountered while waiting for the slave to
start.
2. These warnings and errors are produced in server log file when
the slave I/O thread tries to get the values of the UNIX_TIMESTAMP,
SERVER_ID from master under the transient network disconnection.
To fix problem 1, increase the master retry count to sixty times,
so that the slave I/O thread has enough time to reconnect master
successfully.
To fix problem 2, suppress these warnings and errors by mtr suppression,
because they are expected.
mysql-test/suite/rpl/t/rpl_get_master_version_and_clock-slave.opt:
Added the *.opt file for increasing master retry count to
sixty times.
mysql-test/suite/rpl/t/rpl_get_master_version_and_clock.test:
Added mtr suppression for suppressing warnings and errors
in server log file.
binlog, replication aborts
In SBR or MBR, the schema name is not being written to the binlog
when executing a LOAD DATA statement. This becomes a problem when
the current database (lets call it db1) is different from the
table's schema (lets call it db2). For instance, take the
following statements:
use db1;
load data local infile 'infile.txt' into table db2.t
Should this statement be logged without t's schema (db2), when
replaying it, one can get db1.t populated instead of db2.t (if
db1.t exists). On the other hand, if there is no db1.t at all,
replication will stop.
We fix this by always logging the table (in load file) with fully
qualified name when its schema is different from the current
database or when no default database was selected.
Let
- T be a transactional table and N non-transactional table.
- B be begin, C commit and R rollback.
- N be a statement that accesses and changes only N-tables.
- T be a statement that accesses and changes only T-tables.
In RBR, changes to N-tables that happen early in a transaction are not immediately flushed
upon committing a statement. This behavior may, however, break consistency in the presence
of concurrency since changes done to N-tables become immediately visible to other
connections. To fix this problem, we do the following:
. B N N T C would log - B N C B N C B T C.
. B N N T R would log - B N C B N C B T R.
Note that we are not preserving history from the master as we are introducing a commit that
never happened. However, this seems to be more acceptable than the possibility of breaking
consistency in the presence of concurrency.
The problem is that there is only one autoinc value associated with
the query when binlogging. If more than one autoinc values are used
in the query, the autoinc values after the first one can be inserted
wrongly on slave. So these autoinc values can become inconsistent on
master and slave.
The problem is resolved by marking all the statements that invoke
a trigger or call a function that updated autoinc fields as unsafe,
and will switch to row-format in Mixed mode. Actually, the statement
is safe if just one autoinc value is used in sub-statement, but it's
impossible to check how many autoinc values are used in sub-statement.)
mysql-test/suite/rpl/r/rpl_auto_increment_update_failure.result:
Test result for bug#45677
mysql-test/suite/rpl/t/rpl_auto_increment_update_failure.test:
Added test to verify the following two properties:
P1) insert/update in an autoinc column causes statement to
be logged in row format if binlog_format=mixed
P2) if binlog_format=mixed, and a trigger or function contains
two or more inserts/updates in a table that has an autoinc
column, then the slave should not go out of sync, even if
there are concurrent transactions.
sql/sql_base.cc:
Added function 'has_write_table_with_auto_increment' to check
if one (or more) write tables have auto_increment columns.
Removed function 'has_two_write_locked_tables_with_auto_increment',
because the function is included in function
'has_write_table_with_auto_increment'.
"load data" statements were written to the binlog as a mix of the original statement
and bits recreated from parse-info. This relied on implementation details and broke
with IGNORE_SPACES and versioned comments.
We now completely resynthesize the query for LOAD DATA for binlog (which among other
things normalizes them somewhat with regard to case, spaces, etc.).
We have already parsed the query properly, so we make use of that rather
than mix-and-match string literals and parsed items.
This should make us safe with regard to versioned comments, even those
spanning multiple tokens. Also no longer affected by IGNORE_SPACES.
mysql-test/r/mysqlbinlog.result:
LOAD DATA INFILE normalized
mysql-test/suite/binlog/r/binlog_killed_simulate.result:
LOAD DATA INFILE normalized
mysql-test/suite/binlog/r/binlog_row_mix_innodb_myisam.result:
LOAD DATA INFILE normalized
mysql-test/suite/binlog/r/binlog_stm_blackhole.result:
LOAD DATA INFILE normalized
mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result:
LOAD DATA INFILE normalized
mysql-test/suite/rpl/r/rpl_innodb_mixed_dml.result:
LOAD DATA INFILE normalized
mysql-test/suite/rpl/r/rpl_loaddata.result:
LOAD DATA INFILE normalized
mysql-test/suite/rpl/r/rpl_loaddata_fatal.result:
LOAD DATA INFILE normalized; offsets adjusted to reflect that
mysql-test/suite/rpl/r/rpl_loaddata_map.result:
LOAD DATA INFILE normalized
mysql-test/suite/rpl/r/rpl_loaddatalocal.result:
test for #43746 - trying to break LOAD DATA part of parser
mysql-test/suite/rpl/r/rpl_stm_log.result:
LOAD DATA INFILE normalized
mysql-test/suite/rpl/t/rpl_loaddatalocal.test:
try to break the LOAD DATA part of the parser (test for #43746)
mysql-test/t/mysqlbinlog.test:
LOAD DATA INFILE normalized; adjust offsets to reflect that
sql/log_event.cc:
clean up Load_log_event::print_query and friends so they don't print
excess spaces. add support for printing charset names to print_query.
sql/log_event.h:
We already have three places where we synthesize LOAD DATA queries.
Better use one of those!
sql/sql_lex.h:
When binlogging LOAD DATA statements, we make up the statement to
be logged (from the parse-info, rather than substrings of the
original query) now. Consequently, we no longer need (string-)
pointers into the original query.
sql/sql_load.cc:
Completely rewrote write_execute_load_query_log_event() to synthesize the
LOAD DATA statement wholesale, rather than piece it together from
synthesized bits and literal excerpts from the original query. This
will not only give us a nice, normalized statement (all uppercase,
no excess spaces, etc.), it will also handle comments, including
versioned comments right, which is certainly more than we can say
about the previous incarnation.
sql/sql_yacc.yy:
We're no longer assembling LOAD DATA statements from bodyparts of the
original query, so some bookkeeping in the parser can go.
All statements executed by mysql_upgrade are binlogged and then are replicated to slave.
This will result in some errors. The report of this bug has demonstrated some examples.
Master and slave should be upgraded separately. All statements executed by
mysql_upgrade will not be binlogged.
--write-binlog and --skip-write-binlog options are added into mysql_upgrade.
These options control whether sql statements are binlogged or not.
HA_ERR_WRONG_INDEX
In RBR, disabling keys on slave table will break replication when
updating or deleting a record. When the slave thread tries to
find the row, by searching in the storage engine, it checks
whether the table has a key or not. If it has one, then the slave
thread uses it to search the record.
Nonetheless, the slave only checks whether the key exists or not,
it does not verify if it is active. Should the key be
disabled (eg, DBA has issued an ALTER TABLE ... DISABLE KEYS)
then it will result in error: HA_ERR_WRONG_INDEX.
This patch addresses this issue by making the slave thread also
check whether the key is active or not before actually using it.
The failure is not reproduced on 5.1, so enable the 'rpl_cross_version' test.
mysql-test/suite/rpl/t/disabled.def:
Got rid of the line for enabling 'rpl_cross_version' test.
Network error happened here, but it can be caused by CR_CONNECTION_ERROR,
CR_CONN_HOST_ERROR, CR_SERVER_GONE_ERROR, CR_SERVER_LOST, ER_CON_COUNT_ERROR,
and ER_SERVER_SHUTDOWN. We just check CR_SERVER_LOST here, so the test fails.
To fix the problem, check all errors that can be cause by the master shutdown.
mysql-test/extra/rpl_tests/rpl_get_master_version_and_clock.test:
Added a 'if' sentence to check all errors that can be cause by the master shutdown.
mysql-test/suite/rpl/r/rpl_get_master_version_and_clock.result:
Test result is updated duo to the patch of bug#46931
But there is no Last_IO_Error reported.
On the master, if a binary log event is larger than max_allowed_packet,
ER_MASTER_FATAL_ERROR_READING_BINLOG and the specific reason of this error is
sent to a slave when it requests a dump from the master, thus leading
the I/O thread to stop.
On a slave, the I/O thread stops when receiving a packet larger than max_allowed_packet.
In both cases, however, there was no Last_IO_Error reported.
This patch adds code to report the Last_IO_Error and exact reason before stopping the
I/O thread and also reports the case the out memory pops up while
handling packets from the master.
sql/sql_repl.cc:
The master send the Specific reasons instead of "error reading log entry" to the slave which is requesting a dump.
if an fatal error is returned by read_log_event function.
The test case rpl_do_grant fails sporadically on PB2 with "Access
denied for user 'create_rout_db'@'localhost' ...". Inspecting the
test case, one may find that if issues a GRANT on the master
connection and immediately after it creates two new connections
(one to the master and one to the slave) using the credentials
set with the GRANT.
Unfortunately, there is no synchronization between master and
slave after the grant and before the connections are
established. This can result in slave not having executed the
GRANT by the time the connection is attempted.
This patch fixes this by deploying a sync_slave_with_master
between the grant and the connections attempt.
The test case creates two temporary tables, then closes the
connection, waits for it to disconnect, then syncs the slave with
the master, checks for remaining opened temporary tables on
slave (which should be 0) and finally drops the used
database (mysqltest).
Unfortunately, sometimes, the test fails with one open table on
the slave. This seems to be caused by the fact that waiting for
the connection to be closed is not sufficient. The test needs to
wait for the DROP event to be logged and only then synchronize
the slave with the master and proceed with the check. This is
caused by the asynchronous nature of the disconnect wrt
binlogging of the DROP temporary table statement.
We fix this by deploying a call to wait_for_binlog_event.inc
on the test case, which makes execution to wait for the DROP
temp tables event before synchronizing master and slave.
In RBR, There is an inconsistency between slaves and master.
When INSERT statement which includes an auto_increment field is executed,
Store engine of master will check the value of the auto_increment field.
It will generate a sequence number and then replace the value, if its value is NULL or empty.
if the field's value is 0, the store engine will do like encountering the NULL values
unless NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
In contrast, if the field's value is 0, Store engine of slave always generates a new sequence number
whether or not NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
SQL MODE of slave sql thread is always consistency with master's.
Another variable is related to this bug.
If generateing a sequence number is decided by the values of
table->auto_increment_field_not_null and SQL_MODE(if includes MODE_NO_AUTO_VALUE_ON_ZERO)
The table->auto_increment_is_not_null is FALSE, which causes this bug to appear. ..
Essentially, Bug#45574 results in this bug. The 'CREATE DATABASE IF NOT EXISTS' statement was not
binlogged, when the database has existed.
Sometimes, the master and slaves become inconsistent. The "CREATE DATABASE
IF NOT EXISTS mysqltest1" statement is not binlogged
if the db 'mysqltest1' existed before the test case is executed.
So the db 'mysqltest1' can't be created on slave.
Patch of Bug#45574 has resolved this problem.
But I think it is better to replace 'mysqltest1' by default db 'test'.
If an EVENT is created without the DEFINER clause set explicitly or with it set
to CURRENT_USER, the master and slaves become inconsistent. This issue stems from
the fact that in both cases, the DEFINER is set to the CURRENT_USER of the current
thread. On the master, the CURRENT_USER is the mysqld's user, while on the slave,
the CURRENT_USER is empty for the SQL Thread which is responsible for executing
the statement.
To fix the problem, we do what follows. If the definer is not set explicitly,
a DEFINER clause is added when writing the query into binlog; if 'CURRENT_USER' is
used as the DEFINER, it is replaced with the value of the current user before
writing to binlog.
mysql-test/suite/rpl/r/rpl_create_if_not_exists.result:
Updated the result file after fixing bug#44331
mysql-test/suite/rpl/r/rpl_drop_if_exists.result:
Updated the result file after fixing bug#44331
mysql-test/suite/rpl/r/rpl_events.result:
Test result of Bug#44331
mysql-test/suite/rpl/r/rpl_innodb_mixed_dml.result:
Updated the result file after fixing bug#44331
mysql-test/suite/rpl/t/rpl_events.test:
Added test to verify if the definer is consistent between master and slave
when the event is created without the DEFINER clause set explicitly or the
DEFINER is set to CURRENT_USER
sql/events.cc:
The "create_query_string" function is added to create a new query string
for removing executable comments.
sql/sql_yacc.yy:
The remember_name token was added for recording the offset of EVENT_SYM.
Slave does not correctly handle "expected errors" leading to inconsistencies
between the mater and slave. Specifically, when a statement changes both
transactional and non-transactional tables, the transactional changes are
automatically rolled back on the master but the slave ignores the error and
does not roll them back thus leading to inconsistencies.
To fix the problem, we automatically roll back a statement that fails on
the slave but note that the transaction is not rolled back unless a "rollback"
command is in the relay log file.
mysql-test/extra/rpl_tests/rpl_mixing_engines.test:
Enabled item 13.e which was disabled because of the bug fixed by the
current and removed item 14 which was introduced by mistake.
binlog
Mixing transactional (T) and non-transactional (N) tables on behalf of a
transaction may lead to inconsistencies among masters and slaves in STATEMENT
mode. The problem stems from the fact that although modifications done to
non-transactional tables on behalf of a transaction become immediately visible
to other connections they do not immediately get to the binary log and therefore
consistency is broken. Although there may be issues in mixing T and M tables in
STATEMENT mode, there are safe combinations that clients find useful.
In this bug, we fix the following issue. Mixing N and T tables in multi-level
(e.g. a statement that fires a trigger) or multi-table table statements (e.g.
update t1, t2...) were not handled correctly. In such cases, it was not possible
to distinguish when a T table was updated if the sequence of changes was N and T.
In a nutshell, just the flag "modified_non_trans_table" was not enough to reflect
that both a N and T tables were changed. To circumvent this issue, we check if an
engine is registered in the handler's list and changed something which means that
a T table was modified.
Check WL 2687 for a full-fledged patch that will make the use of either the MIXED or
ROW modes completely safe.
mysql-test/suite/binlog/r/binlog_row_mix_innodb_myisam.result:
Truncate statement is wrapped in BEGIN/COMMIT.
mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result:
Truncate statement is wrapped in BEGIN/COMMIT.
In STATEMENT based replication, a statement that failed on the master but that
updated non-transactional tables is written to binary log with the error code
appended to it. On the slave, the statement is executed and the same error is
expected. However, when an "expected error" did not happen on the slave and was
either ignored or was related to a concurrency issue on the master, the slave
did not rollback the effects of the statement and as such inconsistencies might
happen.
To fix the problem, we automatically rollback a statement that should have
failed on a slave but succeded and whose expected failure is either ignored or
stems from a concurrency issue on the master.
If the log_bin_trust_function_creators option is not defined, creating a stored
function requires either one of the modifiers DETERMINISTIC, NO SQL, or READS
SQL DATA. Executing a stored function should also follows the same rules if in
STATEMENT mode. However, this was not happening and a wrong error was being
printed out: ER_BINLOG_ROW_RBR_TO_SBR.
The patch makes the creation and execution compatible and prints out the correct
error ER_BINLOG_UNSAFE_ROUTINE when a stored function without one of the modifiers
above is executed in STATEMENT mode.
to wrong result
When using MIXED mode and issuing 'CREATE TEMPORARY TABLE t_tmp',
the statement is logged if the current binlogging mode is
STATEMENT. This causes the slave to replay the instruction and
create the temporary table as well. If there is no switch to ROW
mode, and later on a 'DROP TEMPORARY TABLE t_tmp' is issued, then
this statement will also be logged and the slave will
remove/close the temporary table.
However, if there is a switch to ROW mode between the CREATE and
DROP TEMPORARY table, the DROP statement will not be logged,
leaving the slave with a dangling temporary table.
This patch addresses this, by always logging a DROP TEMPORARY
TABLE IF EXISTS when in mixed mode and a drop statement is issued
for temporary table(s).
mysql-test/suite/rpl/r/rpl_temp_table_mix_row.result:
Updated result file.
mysql-test/suite/rpl/t/rpl_temp_table_mix_row.test:
Added test case.
sql/sql_table.cc:
When dropping table(s) in mixed mode and current statement
logging is ROW, builds an extra DROP TEMPORARY TABLE IF
EXISTS for temporary tables that are being dropped. Later,
it logs the extra drop statement.
binlog
The fix for BUG 43929 introduced a regression issue. In a nutshell, when a
statement that changes a non-transactional table fails, it is written to the
binary log with the error code appended. Unfortunately, after BUG 43929, this
failure was flushing the transactional chace causing mismatch between execution
and logging histories. To fix this issue, we avoid flushing the transactional
cache when a commit or rollback is not issued.
The "get_master_version_and_clock(...)" function in sql/slave.cc ignores
error and passes directly when queries fail, or queries succeed
but the result retrieved is empty.
The "get_master_version_and_clock(...)" function should try to reconnect master
if queries fail because of transient network problems, and fail otherwise.
The I/O thread should print a warning if the some system variables do not
exist on master (very old master)
mysql-test/extra/rpl_tests/rpl_get_master_version_and_clock.test:
Added test file for bug #45214
mysql-test/suite/rpl/r/rpl_get_master_version_and_clock.result:
Added test result for bug #45214
mysql-test/suite/rpl/t/rpl_get_master_version_and_clock.test:
Added test file for bug #45214
sql/slave.cc:
The 'is_network_error()' function is added for checking if the error is caused by network.
Added a new return value (2) to 'get_master_version_and_clock()' function result set
to indicate transient network errors when queries fail, and the caller should
try to reconnect in this case.
There is an inconsistency with DROP DATABASE|TABLE|EVENT IF EXISTS and
CREATE DATABASE|TABLE|EVENT IF NOT EXISTS. DROP IF EXISTS statements are
binlogged even if either the DB, TABLE or EVENT does not exist. In
contrast, Only the CREATE EVENT IF NOT EXISTS is binlogged when the EVENT
exists.
This patch fixes the following cases for all the replication formats:
CREATE DATABASE IF NOT EXISTS.
CREATE TABLE IF NOT EXISTS,
CREATE TABLE IF NOT EXISTS ... LIKE,
CREAET TABLE IF NOT EXISTS ... SELECT.
sql/sql_insert.cc:
Part of the code was moved from the create_table_from_items to select_create::prepare.
When replication is row based, CREATE TABLE IF NOT EXISTS.. SELECT is binlogged if the table exists.
Had attempted to disable this test on Windows only, but the nature of this bug
does not allow for this. The master.opt file is processed before anything in
in the actual test. As a result, we must use disabled.def files to ensure
these tests are skipped on the problematic platforms.
Removed Windows-only code and updated the proper disabled.def files accordingly.
timeout
In STMT and MIXED modes, a statement that changes both non-transactional and
transactional tables must be written to the binary log whenever there are
changes to non-transactional tables. This means that the statement gets into the
binary log even when the changes to the transactional tables fail. In particular
, in the presence of a failure such statement is annotated with the error number
and wrapped in a begin/rollback. On the slave, while applying the statement, it
is expected the same failure and the rollback prevents the transactional changes
to be persisted.
Unfortunately, statements that fail due to concurrency issues (e.g. deadlocks,
timeouts) are logged in the same way causing the slave to stop as the statements
are applied sequentially by the SQL Thread. To fix this bug, we automatically
ignore concurrency failures on the slave. Specifically, the following failures
are ignored: ER_LOCK_WAIT_TIMEOUT, ER_LOCK_DEADLOCK and ER_XA_RBDEADLOCK.