unknown e436b8866b BUG#45999 Row based replication fails when auto_increment field = 0
In RBR, There is an inconsistency between slaves and master.
When INSERT statement which includes an auto_increment field is executed,
Store engine of master will check the value of the auto_increment field. 
It will generate a sequence number and then replace the value, if its value is NULL or empty.
if the field's value is 0, the store engine will do like encountering the NULL values 
unless NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
In contrast, if the field's value is 0, Store engine of slave always generates a new sequence number 
whether or not NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.

SQL MODE of slave sql thread is always consistency with master's.
Another variable is related to this bug.
If generateing a sequence number is decided by the values of
table->auto_increment_field_not_null and SQL_MODE(if includes MODE_NO_AUTO_VALUE_ON_ZERO)
The table->auto_increment_is_not_null is FALSE, which causes this bug to appear. ..
2009-09-10 18:05:53 +08:00
..
include Fixed rpl_innodb_mixed_ddl and rpl_000015. 2009-04-26 22:21:01 +01:00
r BUG#45999 Row based replication fails when auto_increment field = 0 2009-09-10 18:05:53 +08:00
t Bug #44331 Restore of database with events produces warning in replication 2009-08-31 10:26:01 +08:00
combinations WL#4350 Options in my.cnf style config file should not start with -- 2008-09-05 15:31:09 +02:00
my.cnf Fix comment 2008-04-08 10:11:07 +02:00
README
rpl_1slave_base.cnf BUG#40257: Please remove --loose-skip-innodb from suite/rpl/rpl_1slave_base.cnf 2008-11-04 18:07:14 +01:00

How to run.
===========

./mysql-test-run.pl --suite=rpl --mysqld=--binlog-format=mixed