Bug #49984 Test 'rpl_loaddata_symlink' fails with "Could not find target log"
Sometimes the symbolic link is available on Windows if
you have some Unix (emulation) layer installed like
Cygwin, MKS or other. But symbolic link is not always
available. It depends on versions, file volume and
system environment of Windows. And the symbolic link
is not typically used on Windows, at least not in the
degree and style they are used on Unix. We can not
change the test case to do without symbolic link,
because the test case is used to test that if the
symbolic link works fine.
To fix the problem, skip the test on windows.
Need to make sure the tmp join doesn't point to the structure already
freed by the cleanup() for the "base" join, as this can lead to
double free, because sometimes both tmp_join and join point to the
same tmp_table_params.copy_field array.
path names than 99 characters, using the USTAR format of the
resulting source TAR.
To be able to specify the use of USTAR when creating the source
TAR, we needed both to update the GNU autotools version requirements
slightly, and update the initiation of the tools to use more
modern constructs.
error in the query.
Fixes a leak after materializing a GROUP BY subquery to a
temp table when the subquery has a blob column in the SELECT
list.
Fixed by correctly destructing temporary buffers for re-usable
queries
The test case rpl_binlog_corruption fails on windows because when
adding a line to the binary log index file it gets terminated
with a CR+LF (which btw, is the normal case in windows, but not on
Unixes - LF). This causes mismatch between the relay log names,
causing mysqld to report that it cannot find the log file.
We fix this by creating the instrumented index file through
mysql, ie, using SELECT ... INTO DUMPFILE ..., as opposed on
relying on ultimatly OS commands like: -- echo "..." >
index. These changes go into the file and make the procedure
platform independent:
include/setup_fake_relay_log.inc
Side note: when using SELECT ... INTO DUMPFILE ..., one needs to
check if mysqld is running with secure_file_priv. If it is, we do
it in two steps: 1. create the file on the allowed location;
2. move it to the datadir. If it is not, then we just create the
file directly on the datadir (so previous step 2. is not needed).
REVOKE/GRANT; ALTER EVENT.
The following statements support the CURRENT_USER() where a user is needed.
DROP USER
RENAME USER CURRENT_USER() ...
GRANT ... TO CURRENT_USER()
REVOKE ... FROM CURRENT_USER()
ALTER DEFINER = CURRENT_USER() EVENT
but, When these statements are binlogged, CURRENT_USER() just is binlogged
as 'CURRENT_USER()', it is not expanded to the real user name. When slave
executes the log event, 'CURRENT_USER()' is expand to the user of slave
SQL thread, but SQL thread's user name always NULL. This breaks the replication.
After this patch, All above statements are rewritten when they are binlogged.
The CURRENT_USER() is expanded to the real user's name and host.
column is used for ORDER BY
Problem: filesort isn't meant for null length sort data
(e.g. char(0)), that leads to a server crash.
Fix: disregard sort order if sort data record length is 0 (nothing
to sort).
in multitable delete/subquery
SQL_BUFFER_RESULT should not have an effect on non-SELECT
statements according to our documentation.
Fixed by not passing it through to multi-table DELETE (similarly
to how it's done for multi-table UPDATE).
Rename method as to not hide a base.
Reorder attributes initialization.
Remove unused variable.
Rework code to silence a warning due to assignment used as truth value.
printstack() being present
When Bug#47391 was fixed, no assumption was made that support
for Solaris 8 was needed. Solaris 8 lacks printstack(), and
the build breaks because of this.
This patch adds a test for the presence of printstack() to
configure.in for 5.0, and uses HAVE_PRINTSTACK to make
decisions rather than the __sun define.
The 'rpl_get_master_version_and_clock' test verifies if the slave I/O
thread tries to reconnect to master when it tries to get the values of
the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection.
So the master server is restarted for making the transient network
disconnection, during the period the COM_REGISTER_SLAVE failures are
produced in server log file when the slave I/O thread tries to
register on master.
To fix the problem, suppress COM_REGISTER_SLAVE failures in server log
file by mtr suppression, because they are expected.
MySQL's hash functions MD5 and SHA relied on the somewhat slow
sprintf function to convert the digests to hex representations.
This patch replaces the sprintf with a specific and inline hex
conversion function.
Patch contributed by Jan Steemann.
When replicating from 4.1 master to 5.0 slave START SLAVE UNTIL can stop too late.
The necessary in calculating of the beginning of an event the event's length
did not correspond to the master's genuine information at the event's execution time.
That piece of info was changed at the event's relay-logging due to binlog_version<4 event
conversion by IO thread.
Fixed with storing the master genuine Query_log_event size into a new status
variable at relay-logging of the event. The stored info is extacted at the event
execution and participate further to caclulate the correct start position of the event
in the until-pos stopping routine.
The new status variable's algorithm will be only active when the event comes
from the master of version < 5.0 (binlog_version < 4).
Detailed revision comments:
r6471 | calvin | 2010-01-16 01:43:27 +0200 (Sat, 16 Jan 2010) | 4 lines
branches/5.1: fix bug#49396: main.innodb test fails in embedded mode
Change replace_result by using $MYSQLD_DATADIR. Tested in both embedded