mariadb/mysql-test/t/init_connect_basic.test
unknown b00c536378 System variable tests delivered by Folio3 (see WL4288).
BitKeeper/etc/ignore:
  Added mysql-test/linux_sys_vars.inc mysql-test/load_sysvars.inc mysql-test/windows_sys_vars.inc to the ignore list
2008-04-10 15:14:28 +02:00

151 lines
6.6 KiB
Text

############## mysql-test\t\init_connect_basic.test ###########################
# #
# Variable Name: init_connect #
# Scope: GLOBAL #
# Access Type: Dynamic #
# Data Type: string #
# Default Value: #
# Range: #
# #
# #
# Creation Date: 2008-02-07 #
# Author: Rizwan #
# #
# Description: Test Cases of Dynamic System Variable init_connect #
# that checks the behavior of this variable in the following ways#
# * Default Value #
# * Valid & Invalid values #
# * Scope & Access method #
# * Data Integrity #
# #
# Reference: http://dev.mysql.com/doc/refman/5.1/en/ #
# server-system-variables.html #
# #
###############################################################################
--source include/load_sysvars.inc
##############################################
## START OF init_connect TESTS ##
##############################################
#############################################################
# Save initial value #
#############################################################
# save using implicit session scope
SET @global_start_value = @@global.init_connect;
SELECT @global_start_value AS INIT_VALUE;
--echo '#--------------------FN_DYNVARS_036_01------------------#'
###############################################################################
# Test Variable access and assignment with and without @@ #
###############################################################################
# select without @@
--error ER_BAD_FIELD_ERROR
SELECT init_connect;
# access using no scope specified
SELECT @@init_connect;
# assign value without @@
SET @@global.init_connect='SET autocomit=0';
SELECT @@global.init_connect;
# using another syntax for accessing session variable
SET global init_connect='SET autocomit=0';
# accessing variable with scope the wrong way
--Error ER_BAD_FIELD_ERROR
SELECT global init_connect;
--Error ER_PARSE_ERROR
SELECT @@global init_connect;
--echo '#--------------------FN_DYNVARS_036_02-------------------------#'
##################################################################
# Check the DEFAULT value of init_connect for global #
##################################################################
SET @@global.init_connect = 'SET join_buffer_size=8200';
SET @@global.init_connect = DEFAULT;
SELECT @@global.init_connect;
--echo '#--------------------FN_DYNVARS_036_03-------------------------#'
######################################################################
# see if it is accessable using session scope #
######################################################################
--Error ER_GLOBAL_VARIABLE
SET @@session.init_connect = '';
--Error ER_GLOBAL_VARIABLE
SET @@init_connect = '';
--Error ER_INCORRECT_GLOBAL_LOCAL_VAR
SELECT @@session.init_connect;
--Error ER_INCORRECT_GLOBAL_LOCAL_VAR
SELECT @@local.init_connect;
--echo '#--------------------FN_DYNVARS_036_04-------------------------#'
#########################################################################
# Change the value of init_connect to a valid value #
#########################################################################
SET @@global.init_connect="";
SELECT @@global.init_connect;
SET @@global.init_connect='SELECT 1,"abc"';
SELECT @@global.init_connect;
SET @@global.init_connect='SET @yoursql="mysql"';
SELECT @@global.init_connect;
SET @@global.init_connect="SET autocomit=0;REVOKE ALL ON INFORMATION_SCHEMA.*";
SELECT @@global.init_connect;
SET @@global.init_connect='SHOW VARIABLES';
SELECT @@global.init_connect;
SET @@global.init_connect = NULL;
SELECT @@global.init_connect;
#any string is accepted as valid value as its is not verified until runtime
SET @@global.init_connect='abc 123 +-*/';
SELECT @@global.init_connect;
SET @@global.init_connect=this_will_give_syntax_error;
SELECT @@global.init_connect;
SET @@global.init_connect = init_slave;
SELECT @@global.init_connect;
--echo '#--------------------FN_DYNVARS_036_05-------------------------#'
###########################################################################
# Change the value of init_connect to an invalid value for global #
###########################################################################
--Error ER_WRONG_TYPE_FOR_VAR
SET @@global.init_connect = true;
--Error ER_WRONG_TYPE_FOR_VAR
SET @@global.init_connect = false;
--Error ER_WRONG_TYPE_FOR_VAR
SET @@global.init_connect = 1.1;
--Error ER_WRONG_TYPE_FOR_VAR
SET @@global.init_connect = 0;
--Error ER_WRONG_TYPE_FOR_VAR
SET @@global.init_connect = 1;
--Error ER_WRONG_TYPE_FOR_VAR
SET @@global.init_connect = -1;
SET @@global.init_connect = ON;
SELECT @@global.init_connect;
--echo '#--------------------FN_DYNVARS_036_06-------------------------#'
##############################################################################
# Check if the value in GLOBAL Table matches value in variable #
##############################################################################
SELECT @@global.init_connect = (SELECT VARIABLE_VALUE
FROM INFORMATION_SCHEMA.GLOBAL_VARIABLES
WHERE VARIABLE_NAME='init_connect') AS res;
####################################
# Restore initial value #
####################################
SET @@global.init_connect = @global_start_value;
SELECT @@global.init_connect;
#####################################################
# END OF init_connect TESTS #
#####################################################