mariadb/mysql-test/main/my_print_defaults.test
Rucha Deodhar 0805cdebd3 MDEV-25908: -e does not work for my_print_defaults
Analysis: get_defaults_options() rewrites the value for my_defaults_file,
my_defaults_extra_file and  my_defaults_group_suffix to 0. So the config file
can't be read.
Fix: Let handle_options() handle --defaults* option and create a new command
line to pass it to load_defaults().
2021-07-26 13:54:01 +05:30

106 lines
2.7 KiB
Text

--echo # MDEV-24248: my_print_defaults is not taking all the values when using
--echo # -e option which is called from mysql.server (extra_args).
--echo #
--echo # checking for mysql.server
--write_file $MYSQLTEST_VARDIR/tmp/tmp1.cnf
[mariadb]
key_buffer_size=20M
max_allowed_packet=250M
table_open_cache=1000
table_definition_cache=2000
read_buffer_size=1M
thread_cache_size=8
max_connections=1024
long_query_time=60
slow_query_log=1
EOF
--write_file $MYSQLTEST_VARDIR/tmp/tmp2.cnf
[mariadb]
key_buffer_size=20M
max_allowed_packet=250M
table_open_cache=1000
table_definition_cache=2000
read_buffer_size=1M
thread_cache_size=8
max_connections=1024
long_query_time=60
slow_query_log=1
EOF
--exec $MYSQL_MY_PRINT_DEFAULTS --defaults-extra-file=$MYSQLTEST_VARDIR/tmp/tmp1.cnf -c $MYSQLTEST_VARDIR/tmp/tmp2.cnf --mysqld mysql.server
--remove_file $MYSQLTEST_VARDIR/tmp/tmp1.cnf
--remove_file $MYSQLTEST_VARDIR/tmp/tmp2.cnf
--echo #
--echo # MDEV-25908: -e does not work for my_print_defaults
--echo #
--write_file $MYSQLTEST_VARDIR/tmp/tmp1.cnf
[mariadb]
key_buffer_size=20M
max_allowed_packet=250M
table_open_cache=1000
EOF
--write_file $MYSQLTEST_VARDIR/tmp/tmp2.cnf
[mariadb]
key_buffer_size=20M
max_allowed_packet=250M
table_open_cache=1000
EOF
--echo # Testing -e
--exec $MYSQL_MY_PRINT_DEFAULTS -e $MYSQLTEST_VARDIR/tmp/tmp1.cnf -c $MYSQLTEST_VARDIR/tmp/tmp2.cnf --mysqld mysql.server
--echo #Testing --defaults-extra-file
--exec $MYSQL_MY_PRINT_DEFAULTS --defaults-extra-file=$MYSQLTEST_VARDIR/tmp/tmp1.cnf -c $MYSQLTEST_VARDIR/tmp/tmp2.cnf --mysqld mysql.server
--remove_file $MYSQLTEST_VARDIR/tmp/tmp1.cnf
--remove_file $MYSQLTEST_VARDIR/tmp/tmp2.cnf
--echo #
--echo # Testing other options
--echo #
--write_file $MYSQLTEST_VARDIR/tmp/tmp2.cnf
[mariadb]
key_buffer_size=20M
max_allowed_packet=250M
table_open_cache=1000
EOF
--write_file $MYSQLTEST_VARDIR/tmp/tmp3.cnf
[mariadb]
key_buffer_size=20M
max_allowed_packet=250M
table_open_cache=1000
[mariadb.1]
table_definition_cache=2000
read_buffer_size=1M
thread_cache_size=8
EOF
--echo # Testing -c option
--exec $MYSQL_MY_PRINT_DEFAULTS -c $MYSQLTEST_VARDIR/tmp/tmp2.cnf --mysqld mysql.server
--echo # Testing --defaults-file
--exec $MYSQL_MY_PRINT_DEFAULTS --defaults-file=$MYSQLTEST_VARDIR/tmp/tmp2.cnf --mysqld mysql.server
--echo # Testing -g option
--exec $MYSQL_MY_PRINT_DEFAULTS -c $MYSQLTEST_VARDIR/tmp/tmp3.cnf --mysqld mysql.server -g .1
--echo # Testing --defaults-group-suffix
--exec $MYSQL_MY_PRINT_DEFAULTS -c $MYSQLTEST_VARDIR/tmp/tmp3.cnf --mysqld mysql.server --defaults-group-suffix=.1
--echo # Testing --no-defaults
--exec $MYSQL_MY_PRINT_DEFAULTS --no-defaults
--remove_file $MYSQLTEST_VARDIR/tmp/tmp2.cnf
--remove_file $MYSQLTEST_VARDIR/tmp/tmp3.cnf
--echo # End of 10.5 Test