mirror of
https://github.com/MariaDB/server.git
synced 2025-01-27 01:04:19 +01:00
128 lines
5.7 KiB
Text
128 lines
5.7 KiB
Text
#
|
|
# Test the pc.weight wsrep provider option. We set Node #1 to have a high weight and then
|
|
# suspend it. This will cause Nodes #2 and #3 to transition to non-primary component.
|
|
#
|
|
|
|
--source include/big_test.inc
|
|
--source include/galera_cluster.inc
|
|
--source include/have_innodb.inc
|
|
|
|
--connection node_1
|
|
SET GLOBAL wsrep_provider_options = 'pc.weight=3';
|
|
|
|
--source include/wait_until_connected_again.inc
|
|
--source include/galera_suspend.inc
|
|
--sleep 10
|
|
|
|
--connection node_2
|
|
# Do not wait for causality as we are no longer in the primary component
|
|
SET SESSION wsrep_sync_wait=0;
|
|
--source include/wait_until_connected_again.inc
|
|
|
|
SET SESSION wsrep_on=OFF;
|
|
--let $wait_condition = SELECT VARIABLE_VALUE = 'non-Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status'
|
|
--source include/wait_condition.inc
|
|
SET SESSION wsrep_on=ON;
|
|
|
|
# We can not use SELECT queries here, as only SHOW is allowed to run.
|
|
# For nodes #2 and #3, we expect a non-primary component of size 2
|
|
|
|
SHOW STATUS LIKE 'wsrep_cluster_size';
|
|
SHOW STATUS LIKE 'wsrep_cluster_status';
|
|
SHOW STATUS LIKE 'wsrep_connected';
|
|
SHOW STATUS LIKE 'wsrep_ready';
|
|
SHOW STATUS LIKE 'wsrep_local_state';
|
|
SHOW STATUS LIKE 'wsrep_local_state_comment';
|
|
|
|
--let $galera_connection_name = node_3
|
|
--let $galera_server_number = 3
|
|
--source include/galera_connect.inc
|
|
--connection node_3
|
|
SET SESSION wsrep_sync_wait=0;
|
|
--source include/wait_until_connected_again.inc
|
|
|
|
SHOW STATUS LIKE 'wsrep_cluster_size';
|
|
SHOW STATUS LIKE 'wsrep_cluster_status';
|
|
SHOW STATUS LIKE 'wsrep_connected';
|
|
SHOW STATUS LIKE 'wsrep_ready';
|
|
SHOW STATUS LIKE 'wsrep_local_state';
|
|
SHOW STATUS LIKE 'wsrep_local_state_comment';
|
|
|
|
--connection node_1
|
|
--source include/galera_resume.inc
|
|
--sleep 10
|
|
--source include/wait_until_connected_again.inc
|
|
|
|
# For Node #1, we expect a primary component of size 1
|
|
|
|
--let $wait_condition = SELECT VARIABLE_VALUE = 1 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_size'
|
|
--source include/wait_condition.inc
|
|
|
|
SELECT VARIABLE_VALUE = 'Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_connected';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_ready';
|
|
SELECT VARIABLE_VALUE = 4 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state';
|
|
SELECT VARIABLE_VALUE = 'Synced' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state_comment';
|
|
|
|
SET GLOBAL wsrep_provider_options = 'pc.weight=1';
|
|
|
|
# Restore the cluster by resetting wsrep_cluster_address on nodes #1 and #2
|
|
|
|
--connection node_2
|
|
--disable_query_log
|
|
--eval SET GLOBAL wsrep_cluster_address = @@wsrep_cluster_address;
|
|
--enable_query_log
|
|
|
|
SET SESSION wsrep_sync_wait=0;
|
|
--source include/wait_until_connected_again.inc
|
|
|
|
--connection node_3
|
|
--disable_query_log
|
|
--eval SET GLOBAL wsrep_cluster_address = @@wsrep_cluster_address;
|
|
--enable_query_log
|
|
|
|
SET SESSION wsrep_sync_wait=0;
|
|
--source include/wait_until_connected_again.inc
|
|
|
|
# On all nodes, we now expect a Primary component of size 3, Synced and ready
|
|
|
|
--connection node_1
|
|
--source include/wait_until_connected_again.inc
|
|
SELECT VARIABLE_VALUE = 3 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_size';
|
|
SELECT VARIABLE_VALUE = 'Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_connected';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_ready';
|
|
SELECT VARIABLE_VALUE = 4 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state';
|
|
SELECT VARIABLE_VALUE = 'Synced' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state_comment';
|
|
|
|
--connection node_2
|
|
SELECT VARIABLE_VALUE = 3 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_size';
|
|
SELECT VARIABLE_VALUE = 'Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_connected';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_ready';
|
|
SELECT VARIABLE_VALUE = 4 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state';
|
|
SELECT VARIABLE_VALUE = 'Synced' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state_comment';
|
|
|
|
--connection node_3
|
|
SELECT VARIABLE_VALUE = 3 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_size';
|
|
SELECT VARIABLE_VALUE = 'Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_connected';
|
|
SELECT VARIABLE_VALUE = 'ON' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_ready';
|
|
SELECT VARIABLE_VALUE = 4 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state';
|
|
SELECT VARIABLE_VALUE = 'Synced' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_local_state_comment';
|
|
|
|
--connection node_1
|
|
|
|
SET GLOBAL wsrep_provider_options = 'pc.weight=1';
|
|
--let $wait_condition = SELECT @@wsrep_provider_options LIKE '%pc.weight = 1%'
|
|
--source include/wait_condition.inc
|
|
|
|
CALL mtr.add_suppression('WSREP: gcs_caused\\(\\) returned -1');
|
|
|
|
--connection node_2
|
|
CALL mtr.add_suppression('overriding reported weight for');
|
|
|
|
--connection node_3
|
|
CALL mtr.add_suppression('WSREP: user message in state LEAVING');
|
|
CALL mtr.add_suppression('sending install message failed: Transport endpoint is not connected');
|
|
CALL mtr.add_suppression('overriding reported weight for');
|