mirror of
https://github.com/MariaDB/server.git
synced 2025-03-08 04:03:30 +01:00

To-number conversion warnings work differenly with CHAR and VARCHAR sp variables. The original revision-IDs are: staale.smedseng@sun.com-20081124095339-2qdvzkp0rn1ljs30 staale.smedseng@sun.com-20081125104611-rtxic5d12e83ag2o The patch provides ER_TRUNCATED_WRONG_VALUE warning messages for conversion of VARCHAR to numberic values, in line with messages provided for CHAR conversions. Conversions are checked for success, and the message is emitted in case failure. The tests are amended to accept the added warning messages, and explicit conversion of ON/OFF values is added for statements checking system variables. In test rpl.rpl_switch_stm_row_mixed checking for warnings is temporarily disabled for one statement, as this generates warning messages for strings that vary between executions.
119 lines
3.8 KiB
Text
119 lines
3.8 KiB
Text
SET @start_value = @@global.read_only;
|
|
SELECT @start_value;
|
|
@start_value
|
|
0
|
|
'#--------------------FN_DYNVARS_139_01------------------------#'
|
|
SET @@global.read_only = 1;
|
|
SET @@global.read_only = DEFAULT;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
'#---------------------FN_DYNVARS_139_02-------------------------#'
|
|
SET @@global.read_only = @start_value;
|
|
SELECT @@global.read_only = 0;
|
|
@@global.read_only = 0
|
|
1
|
|
'#--------------------FN_DYNVARS_139_03------------------------#'
|
|
SET @@global.read_only = 0;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = 1;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
1
|
|
SET @@global.read_only = TRUE;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
1
|
|
SET @@global.read_only = FALSE;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = ON;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
1
|
|
SET @@global.read_only = OFF;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
'#--------------------FN_DYNVARS_139_04-------------------------#'
|
|
SET @@global.read_only = -1;
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of '-1'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = 4294967296;
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of '4294967296'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = 10240022115;
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of '10240022115'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = 10000.01;
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of '10000'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = -1024;
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of '-1024'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
SET @@global.read_only = 42949672950;
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of '42949672950'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
'Bug # 34837: Errors are not coming on assigning invalid values to variable';
|
|
SET @@global.read_only = 'test';
|
|
ERROR 42000: Variable 'read_only' can't be set to the value of 'test'
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|
|
'#-------------------FN_DYNVARS_139_05----------------------------#'
|
|
SET @@session.read_only = 0;
|
|
ERROR HY000: Variable 'read_only' is a GLOBAL variable and should be set with SET GLOBAL
|
|
SELECT @@read_only;
|
|
@@read_only
|
|
0
|
|
'#----------------------FN_DYNVARS_139_06------------------------#'
|
|
SELECT IF(@@global.read_only, "ON", "OFF") = VARIABLE_VALUE
|
|
FROM INFORMATION_SCHEMA.GLOBAL_VARIABLES
|
|
WHERE VARIABLE_NAME='read_only';
|
|
IF(@@global.read_only, "ON", "OFF") = VARIABLE_VALUE
|
|
1
|
|
SELECT IF(@@read_only, "ON", "OFF") = VARIABLE_VALUE
|
|
FROM INFORMATION_SCHEMA.SESSION_VARIABLES
|
|
WHERE VARIABLE_NAME='read_only';
|
|
IF(@@read_only, "ON", "OFF") = VARIABLE_VALUE
|
|
1
|
|
'#---------------------FN_DYNVARS_139_07----------------------#'
|
|
SET @@global.read_only = 1;
|
|
SELECT @@read_only = @@global.read_only;
|
|
@@read_only = @@global.read_only
|
|
1
|
|
'#---------------------FN_DYNVARS_139_08----------------------#'
|
|
SET read_only = 1;
|
|
ERROR HY000: Variable 'read_only' is a GLOBAL variable and should be set with SET GLOBAL
|
|
SELECT @@read_only;
|
|
@@read_only
|
|
1
|
|
SET local.read_only = 1;
|
|
ERROR 42000: You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'read_only = 1' at line 1
|
|
SELECT local.read_only;
|
|
ERROR 42S02: Unknown table 'local' in field list
|
|
SET global.read_only = 1;
|
|
ERROR 42000: You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'read_only = 1' at line 1
|
|
SELECT global.read_only;
|
|
ERROR 42S02: Unknown table 'global' in field list
|
|
SELECT read_only = @@session.read_only;
|
|
ERROR 42S22: Unknown column 'read_only' in 'field list'
|
|
SET @@global.read_only = @start_value;
|
|
SELECT @@global.read_only;
|
|
@@global.read_only
|
|
0
|