mariadb/mysql-test/suite/galera_3nodes/t/galera-features#115.test

89 lines
3.3 KiB
Text

#
# This test tests that one successful node wins over two nodes that fail for
# different reasons
#
--source include/galera_cluster.inc
--source include/have_innodb.inc
--let $galera_connection_name = node_3
--let $galera_server_number = 3
--source include/galera_connect.inc
--let $node_1=node_1
--let $node_2=node_2
--let $node_3=node_3
--source suite/galera/include/auto_increment_offset_save.inc
# create inconsistency on node 2
--connection node_2
SET GLOBAL wsrep_on=OFF;
DROP SCHEMA test;
# create inconsistency on node 3
--connection node_3
SET GLOBAL wsrep_on=OFF;
CREATE TABLE t1 (f1 INTEGER);
--connection node_1
CREATE TABLE t1 (f1 INTEGER);
# check that nodes 2 and 3 leave the cluster, and node_1 is Primary by itself
--connection node_1
SET SESSION wsrep_sync_wait=0;
--let $wait_condition = SELECT VARIABLE_VALUE = 1 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_size';
--source include/wait_condition.inc
--connection node_2
SET SESSION wsrep_sync_wait=0;
--let $wait_condition = SELECT VARIABLE_VALUE = 'Disconnected' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
--source include/wait_condition.inc
--connection node_3
SET SESSION wsrep_sync_wait=0;
--let $wait_condition = SELECT VARIABLE_VALUE = 'Disconnected' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
--source include/wait_condition.inc
--connection node_1
# this is a workaround for "sending install message failed" BUG:
# https://github.com/codership/galera/issues/174
# When it happens, node_1 becomes non-prim
SET GLOBAL wsrep_provider_options='pc.bootstrap=YES';
--let $wait_condition = SELECT VARIABLE_VALUE = 'Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
--source include/wait_condition.inc
# restart nodes 2 and 3, since they failed
--connection node_2
# need to reinitialize connection due to a "Bad handshake" bug.
# we reconnect using the 'mysql' database as 'test' was dropped.
--disconnect node_2
--connect node_2, 127.0.0.1, root, , mysql, $NODE_MYPORT_2
--source include/restart_mysqld.inc
--connection node_3
--source include/restart_mysqld.inc
--connection node_1
--let $wait_condition = SELECT VARIABLE_VALUE = 3 FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_size';
--source include/wait_condition.inc
--let $wait_condition = SELECT VARIABLE_VALUE = 'Primary' FROM INFORMATION_SCHEMA.GLOBAL_STATUS WHERE VARIABLE_NAME = 'wsrep_cluster_status';
--source include/wait_condition.inc
DROP TABLE test.t1;
--source suite/galera/include/auto_increment_offset_restore.inc
--connection node_2
CALL mtr.add_suppression("Inconsistent by consensus\\.");
CALL mtr.add_suppression("Error_code: 1049");
CALL mtr.add_suppression("WSREP: Failed to apply trx: source: ");
CALL mtr.add_suppression("WSREP: Failed to apply app buffer");
CALL mtr.add_suppression("WSREP: Node consistency compromized, leaving cluster\\.\\.\\.");
--connection node_3
CALL mtr.add_suppression("Inconsistent by consensus\\.");
CALL mtr.add_suppression("Error_code: 1050");
CALL mtr.add_suppression("WSREP: Failed to apply trx: source: ");
CALL mtr.add_suppression("WSREP: Failed to apply app buffer");
CALL mtr.add_suppression("WSREP: Node consistency compromized, leaving cluster\\.\\.\\.");