The problem was that some facilities (like CONVERT_TZ() function or
server HELP statement) may require implicit access to some tables in
'mysql' database. This access was done by ordinary means of adding
such tables to the list of tables the query is going to open.
However, if we issued LOCK TABLES before that, we would get "table
was not locked" error trying to open such implicit tables.
The solution is to treat certain tables as MySQL system tables, like
we already do for mysql.proc. Such tables may be opened for reading
at any moment regardless of any locks in effect. The cost of this is
that system table may be locked for writing only together with other
system tables, it is disallowed to lock system tables for writing and
have any other lock on any other table.
After this patch the following tables are treated as MySQL system
tables:
mysql.help_category
mysql.help_keyword
mysql.help_relation
mysql.help_topic
mysql.proc (it already was)
mysql.time_zone
mysql.time_zone_leap_second
mysql.time_zone_name
mysql.time_zone_transition
mysql.time_zone_transition_type
These tables are now opened with open_system_tables_for_read() and
closed with close_system_tables(), or one table may be opened with
open_system_table_for_update() and closed with close_thread_tables()
(the latter is used for mysql.proc table, which is updated as part of
normal MySQL server operation). These functions may be used when
some tables were opened and locked already.
NOTE: online update of time zone tables is not possible during
replication, because there's no time zone cache flush neither on LOCK
TABLES, nor on FLUSH TABLES, so the master may serve stale time zone
data from cache, while on slave updated data will be loaded from the
time zone tables.
trigger fails".
In cases when CONVERT_TZ() function was used in trigger or stored function
(or in stored procedure which was called from trigger or stored function)
error about non existing '.' table was reported.
Statements that use CONVERT_TZ() function should have time zone related
tables in their table list. tz_init_table_list() function which is used
to produce part of table list containing those tables didn't set
TABLE_LIST::db_length/table_name_length members properly. As result time
zone tables needed for CONVERT_TZ() function were incorrectly handled by
prelocking algorithm and "Table '.' doesn't exist' error was emitted.
This fix changes tz_init_table_list() in such way that it properly inits
TABLE_LIST::table_name_length/db_length members and thus produces table list
which can be handled by prelocking algorithm correctly.
- Added empty constructors and virtual destructors to many classes and structs
- Removed some usage of the offsetof() macro to instead use C++ class pointers
- split into several files
- forbid parallel execution (before analyse is done how to make it possible)
because the same sp_head instance cannot be executed in parallel
- added GPL headers
- changed EVENT_ACL to be per DB variable
- fixed minor problems
Change bool in C code to my_bool
Added to mysqltest --enable_parsning and --disable_parsing to avoid to have to comment parts of tests
Added comparison of LEX_STRING's and use this to compare file types for view and trigger files.
IN and CONVERT_TZ()" (with after review changes).
Now we add implicitly used time zone tables to global table list right
at the parsing stage instead of doing it later in mysql_execute_command()
or in check_prepared_statement().
No special test-case needed since this bug also manifests itself as
timezone2.test failure if one runs it with --ps-protocol option.
tables requires privileges for them if some table or column level grants
present" (with after-review fixes).
We should set SELECT_ACL for implicitly opened tables in
my_tz_check_n_skip_implicit_tables() to be able to bypass privilege
checking in check_grant(). Also we should exclude those tables from
privilege checking in multi-update.
Fixed (together with Guilhem) bugs in mysqlbinlog regarding --offset
Prefix addresses with 0x for easier comparisons of debug logs
Fixed problem where MySQL choosed index-read even if there would be a much better range on the same index
This fix changed some 'index' queries to 'range' queries in the test suite
Don't create 'dummy' WHERE clause for trivial WHERE clauses where we can remove the WHERE clause.
This fix removed of a lot of 'Using where' notes in the test suite.
Give NOTE instead of WARNING if table/function doesn't exists when using DROP IF EXISTS
Give NOTE instead of WARNING for safe field-type conversions
Instead of trying to open time zone tables during calculation of CONVERT_TZ() function
or setting of @@time_zone variable we should open and lock them with the rest of
statement's table (so we should add them to global table list) and after that use such
pre-opened tables for loading info about time zones.
options for mysqlbinlog, with a test file.
This enables user to say "recover my database to how it was this morning at 10:30"
(mysqlbinlog "--stop-datetime=2003-07-29 10:30:00").
Using time functions into client/ made me move them out of sql/ into sql-common/.
+ (small) fix for BUG#4507 "mysqlbinlog --read-from-remote-server sometimes
cannot accept 2 binlogs" (that is, on command line).
Added basic per-thread time zone functionality (based on public
domain elsie-code). Now user can select current time zone
(from the list of time zones described in system tables).
All NOW-like functions honor this time zone, values of TIMESTAMP
type are interpreted as values in this time zone, so now
our TIMESTAMP type behaves similar to Oracle's TIMESTAMP WITH
LOCAL TIME ZONE (or proper PostgresSQL type).
WL#1266 "CONVERT_TZ() - basic time with time zone conversion
function".
Fixed problems described in Bug #2336 (Different number of warnings
when inserting bad datetime as string or as number). This required
reworking of datetime realted warning hadling (they now generated
at Field object level not in conversion functions).
Optimization: Now Field class descendants use table->in_use member
instead of current_thd macro.