When binlog_format is STATEMENT and the statement is unsafe before,
the unsafe warning/error message was issued without checking
whether the SQL_LOG_BIN was turned on or not.
Fixed with adding a sql_log_bin_toplevel flag in THD to check
whether SQL_LOG_BIN is ON in current session whatever the current is in sp or not.
In STRICT mode, out-of-bounds values caused an error message
to be queued (rather than just a warning), without any further
error-like processing happening. (The error is queued during
update, at which time it's too late. For it to be processed
properly, it would need to be queued during check-stage.)
The assertion rightfully complains that we're trying to send
an OK while having an error queued.
Changeset breaks a lot of tests out into check-stage. This also
allows us to send more correct warnings/error messages.
In STRICT mode, out-of-bounds values caused an error message
to be queued (rather than just a warning), without any further
error-like processing happening. (The error is queued during
update, at which time it's too late. For it to be processed
properly, it would need to be queued during check-stage.)
The assertion rightfully complains that we're trying to send
an OK while having an error queued.
Changeset breaks a lot of tests out into check-stage. This also
allows us to send more correct warnings/error messages.
- Add support for setting it as a server commandline argument
- Add support for those switches:
= no_index_merge
= no_index_merge_union
= no_index_merge_sort_union
= no_index_merge_intersection
- Remove bothersome warning messages. This change focuses on the warnings
that are covered by the ignore file: support-files/compiler_warnings.supp.
- Strings are guaranteed to be max uint in length
In STRICT mode, out-of-bounds values caused an error message
to be queued (rather than just a warning), without any further
error-like processing happening. (The error is queued during
update, at which time it's too late. For it to be processed
properly, it would need to be queued during check-stage.)
The assertion rightfully complains that we're trying to send
an OK while having an error queued.
Changeset breaks a lot of tests out into check-stage. This also
allows us to send more correct warnings/error messages.
The binlog_innodb test was sensitive to what tests ran before it. Now run
FLUSH STATUS before performing operations that need to be checked.
sys_var_thd_ulong::update() was improperly casting an option value from
ulonglong to ulong before comparing it to the max allowed value. On systems
where ulong and ulonglong are of different size, this caused values greater
than ULONG_MAX to wrap around (not be truncated to ULONG_MAX, which appears to
have been the intention of the original coder), and caused some checks to work
incorrectly. This wasn't generally visible to the user, because later checks
would prevent the wrapped-around value from being used. But it caused warning
messages to differ between 32- and 64-bit platforms. Fix is to just remove the
cast. Also added a DBUG_ASSERT to ensure that the value really is capped
properly before finally stuffing it into the ulong.
The SHOW VARIABLES LIKE .../SELECT @@/SELECT ... FROM INFORMATION_SCHEMA.VARIABLES
were assuming that all the system variables are in system charset (UTF-8).
However the variables that are settable through command line will have a different
character set (character_set_filesystem).
Fixed the server to remember the correct character set of basedir, datadir, tmpdir,
ssl, plugin_dir, slave_load_tmpdir, innodb variables; init_connect and init_slave
variables and use it when processing data.
Several system variables did not behave like system variables should do.
When trying to SET them or use them in SELECT, they were reported as
"unknown system variable". But they appeared in SHOW VARIABLES.
This has been fixed by removing the "fixed_vars" array of variables
and integrating the variables into the normal system variables chain.
All of these variables do now behave as read-only global-only
variables. Trying to SET them tells they are read-only, trying to
SELECT the session value tells they are global only. Selecting the
global value works. It delivers the same value as SHOW VARIABLES.
set but is ignored".
This patch makes @@session.max_allowed_packed and
@@session.net_buffer_length read-only as suggested in the bug
report. The user will have to use SET GLOBAL (and reconnect)
to alter the session values of these variables.
The error string ER_VARIABLE_IS_READONLY is introduced.
Tests are modified accordingly.
The code to get read the value of a system variable was extracting its value
on PREPARE stage and was substituting the value (as a constant) into the parse tree.
Note that this must be a reversible transformation, i.e. it must be reversed before
each re-execution.
Unfortunately this cannot be reliably done using the current code, because there are
other non-reversible source tree transformations that can interfere with this
reversible transformation.
Fixed by not resolving the value at PREPARE, but at EXECUTE (as the rest of the
functions operate). Added a cache of the value (so that it's constant throughout
the execution of the query). Note that the cache also caches NULL values.
Updated an obsolete related test suite (variables-big) and the code to test the
result type of system variables (as per bug 74).
Adds --general_log_file, --slow_query_log_file command-
line options to match system variables of the same names.
Deprecates --log, --log-slow-queries command-line options
and log, log_slow_queries system-variables for v7.0; they
are superseded by general_log/general_log_file and
slow_query_log/slow_query_log_file, respectively.
SUPER is not required to change binlog format for session
A user without SUPER privileges can change the value of the
session variable BINLOG_FORMAT, causing problems for a DBA.
This changeset requires a user to have SUPER privileges to
change the value of the session variable BINLOG_FORMAT, and
not only the global variable BINLOG_FORMAT.
The event scheduler was not designed to work in embedded mode. This
patch disables and excludes the event scheduler when the server is
compiled for embedded build.
general_log_file/slow_query_log_file.
The problem was that log file path was rejected if directory
path was empty. The fix is to reject log file path only if it
is entirely empty.
We have "set" variables, which can accept empty values
(like sql_mode), and which can not (like log_output). The problem
was that the code does not distinguish them and allow empty
values for every set variable.
The fix is to introduce an attribute of a set variable telling
whether it can accept empty values.
Problem: in mixed and statement mode, a query that refers to a
system variable will use the slave's value when replayed on
slave. So if the value of a system variable is inserted into a
table, the slave will differ from the master.
Fix: mark statements that refer to a system variable as "unsafe",
meaning they will be replicated by row in mixed mode and produce a warning
in statement mode. There are some exceptions: some variables are actually
replicated. Those should *not* be marked as unsafe.
BUG#34732: mysqlbinlog does not print default values for auto_increment variables
Problem: mysqlbinlog does not print default values for some variables,
including auto_increment_increment and others. So if a client executing
the output of mysqlbinlog has different default values, replication will
be wrong.
Fix: Always print default values for all variables that are replicated.
I need to fix the two bugs at the same time, because the test cases would
fail if I only fixed one of them.
There was no way to see if report-{host,port,user,password} were set up.
Fixed with introducing new global variables.
The variables are made read-only because of a possible need to change them
most probably require the slave server restart.
Todo: transform the startup options to be CHANGE master parameters - i.e
to deprecate `report-' options, and to change the new vars
to be updatable at time of CHANGE master executes with new
values.