During creation of the table list of
processed tables hidden I_S table 'VARIABLES'
is erroneously added into the table list.
it leads to ER_UNKNOWN_TABLE error in
TABLE_LIST::add_table_to_list() function.
The fix is to skip addition of hidden I_S
tables into the table list.
check_access() returning false for a database does not
guarantee that the access is granted to it.
This wrong condition in filling the INFORMATION_SCHEMA
tables causes extra tables to be returned to the user
even if he has no rights to see them.
Fixed by correcting the condition.
become negative
- merged the fix to 5.1
- extended to cover I_S.PROCESSLIST.TIME
- Changed the column type of I_S.PROCESSLIST.TIME from LOGNLONG
UNSIGNED
to LONG (to match the SHOW PROCESSLIST type)
- Added a test case
Bug#42003 tests missing the disconnect of connections <> default
second slice
Content:
1. wait_until_count_sessions.inc
- One PB run of a test using this routine failed because
5 seconds timeout were exceeded. Although I have some doubts
if the assigned timeout was really too small, I increase the
value to 10. We waste the additional 5 seconds only if the
tests fails anyway.
- Print the content of the PROCESSLIST if the poll routine fails
2. minor improvements of formatting
3. query_cache_notembedded:
Activate the wait_until_count_sessions.inc routine which was
unfortunately forgotten in the changeset before.
- If missing: add "disconnect <session>"
- If physical disconnect of non "default" sessions is not finished
at test end: add routine which waits till this happened
+ additional improvements
- remove superfluous files created by the test
- replace error numbers by error names
- remove trailing spaces, replace tabs by spaces
- unify writing of bugs within comments
- correct comments
- minor changes of formatting
Fixed tests:
backup
check
compress
grant
information_schema
multi_update
overflow
packet
query_cache_not_embedded
sp-threads
subselect
synchronization
timezone_grant
conflicts:
Text conflict in client/mysqltest.cc
Text conflict in mysql-test/include/wait_until_connected_again.inc
Text conflict in mysql-test/lib/mtr_report.pm
Text conflict in mysql-test/mysql-test-run.pl
Text conflict in mysql-test/r/events_bugs.result
Text conflict in mysql-test/r/log_state.result
Text conflict in mysql-test/r/myisam_data_pointer_size_func.result
Text conflict in mysql-test/r/mysqlcheck.result
Text conflict in mysql-test/r/query_cache.result
Text conflict in mysql-test/r/status.result
Text conflict in mysql-test/suite/binlog/r/binlog_index.result
Text conflict in mysql-test/suite/binlog/r/binlog_innodb.result
Text conflict in mysql-test/suite/rpl/r/rpl_packet.result
Text conflict in mysql-test/suite/rpl/t/rpl_packet.test
Text conflict in mysql-test/t/disabled.def
Text conflict in mysql-test/t/events_bugs.test
Text conflict in mysql-test/t/log_state.test
Text conflict in mysql-test/t/myisam_data_pointer_size_func.test
Text conflict in mysql-test/t/mysqlcheck.test
Text conflict in mysql-test/t/query_cache.test
Text conflict in mysql-test/t/rpl_init_slave_func.test
Text conflict in mysql-test/t/status.test
GLOBAL STATUS is calculated by studying the list of threads. In the
embedded server threads were not linked to the internal list, so the
calculation always returns 0. Fixed by 'linking' the embedded-server
threads to the same list
per-file comments:
libmysqld/lib_sql.cc
Bug#34517 SHOW GLOBAL STATUS does not work properly in embedded server.
Add newly created 'threads' to the internal thread list.
Remove them from the list as they're freed.
mysql-test/r/information_schema.result
Bug#34517 SHOW GLOBAL STATUS does not work properly in embedded server.
test result
mysql-test/t/information_schema.test
Bug#34517 SHOW GLOBAL STATUS does not work properly in embedded server.
test case added
VARIABLE_VALUE field is decreased to 1024 symbols.
(affected I_S tables: GLOBAL_VARIABLES, SESSION_VARIABLES,
GLOBAL_STATUS, SESSION_STATUS).
The only variable which can be longer than 1024 is
init_connect. The variable will be truncated with warning.
Additional fix:
Added where condition filter which speed up queries which
have where condition with expressions which use VARIABLE_NAME
field.
changed 'charset', 'collation' field length from 64 to MY_CS_NAME_SIZE(32)
in tables:
SCHEMATA, TABLES, COLUMNS, CHARACTER_SETS,
COLLATIONS, COLLATION_CHARACTER_SET_APPLICABILITY
When swapping out heap I_S tables to disk, this is done after plan refinement.
Thus, READ_RECORD::file will still point to the (deleted) heap handler at start
of execution. This causes segmentation fault if join buffering is used and the
query is a star query where the result is found to be empty before accessing
some table. In this case that table has not been initialized (i.e. had its
READ_RECORD re-initialized) before the cleanup routine tries to close the handler.
Fixed by updating READ_RECORD::file when changing handler.
m_status == DA_OK
Reading from information_scema.tables or information_schema.columns
may cause assertion failure in debug builds. This may happen under
rare circumstances when information_schema fails to get information
about a table (e.g. when a connection is killed).
This happens because open_normal_and_derived_tables() can return an
error without setting an error message in THD. But information_schema
attempts to get an error message from THD unconditionally.
With this fix information_schema attempts to get an error message
from THD only in case error message is set in THD.
between 5.0 and 5.1.
The problem was that in the patch for Bug#11986 it was decided
to store original query in UTF8 encoding for the INFORMATION_SCHEMA.
This approach however turned out to be quite difficult to implement
properly. The main problem is to preserve the same IS-output after
dump/restore.
So, the fix is to rollback to the previous functionality, but also
to fix it to support multi-character-set-queries properly. The idea
is to generate INFORMATION_SCHEMA-query from the item-tree after
parsing view declaration. The IS-query should:
- be completely in UTF8;
- not contain character set introducers.
For more information, see WL4052.
The problem is that one can not create a stored routine if sql_mode
contains NO_ENGINE_SUBSTITUTION or PAD_CHAR_TO_FULL_LENGTH. Also when
a event is created, the mode is silently lost if sql_mode contains one
of the aforementioned. This was happening because the table definitions
which stored sql_mode values weren't being updated to accept new values
of sql_mode.
The solution is to update, in a backwards compatible manner, the various
table definitions (columns) that store the sql_mode value to take into
account the new possible values. One incompatible change is that if a event
that is being created can't be stored to the mysql.event table, an error
will be raised.
The tests case also ensure that new SQL modes will be added to the mysql.proc
and mysql.event tables, otherwise the tests will fail.
pre-locking.
The crash was caused by an implicit assumption in check_table_access() that
table_list parameter is always a part of lex->query_tables.
When iterating over the passed list of tables, check_table_access() used
to stop only when lex->query_tables_last_not_own was reached.
In case of pre-locking, lex->query_tables_last_own is not NULL and points
to some element of lex->query_tables. When the parameter
of check_table_access() was not part of lex->query_tables, loop invariant
could never be violated and a crash would happen when the current table
pointer would point beyond the end of the provided list.
The fix is to change the signature of check_table_access() to also accept
a numeric limit of loop iterations, similarly to check_grant(), and
supply this limit in all places when we want to check access of tables
that are outside lex->query_tables, or just want to check access to one table.
command and reported to a client.
The fact that a timestamp field will be set to NO on UPDATE wasn't shown
by the SHOW COMMAND and reported to a client through connectors. This led to
problems in the ODBC connector and might lead to a user confusion.
A new filed flag called ON_UPDATE_NOW_FLAG is added.
Constructors of the Field_timestamp set it when a field should be set to NOW
on UPDATE.
The get_schema_column_record function now reports whether a timestamp field