All statements executed by mysql_upgrade are binlogged and then are replicated to slave.
This will result in some errors. The report of this bug has demonstrated some examples.
Master and slave should be upgraded separately. All statements executed by
mysql_upgrade will not be binlogged.
--write-binlog and --skip-write-binlog options are added into mysql_upgrade.
These options control whether sql statements are binlogged or not.
In RBR, 'DROP TEMPORARY TABLE IF EXISTS...' statement is binlogged when the table
does not exist.
In fact, 'DROP TEMPORARY TABLE ...' statement should never be binlogged in RBR
no matter if the table exists or not.
This patch addresses this by checking whether we are dropping a
temporary table or not, when building the custom drop statement.
failure to cleanup of table
The test case was not dropping a table before exiting (ie, it was
not cleaning itself after execution). In this case, the warning
message stating that the test did not do a proper cleanup was
deterministic (which can be annoying).
I have found other tests cases on which mtr sporadically reports
that they have not cleaned up after execution:
- rpl_ndb_circular
- rpl_failed_optimize
In this case, the master was dropping a table but there was no
synchronization between the slave and the master.
This patch addresses the rpl_ndb_circular_simplex case by adding
the missing DROP table. The other cases are fixed by deploying
the missing sync_slave_with_master instruction.
HA_ERR_WRONG_INDEX
In RBR, disabling keys on slave table will break replication when
updating or deleting a record. When the slave thread tries to
find the row, by searching in the storage engine, it checks
whether the table has a key or not. If it has one, then the slave
thread uses it to search the record.
Nonetheless, the slave only checks whether the key exists or not,
it does not verify if it is active. Should the key be
disabled (eg, DBA has issued an ALTER TABLE ... DISABLE KEYS)
then it will result in error: HA_ERR_WRONG_INDEX.
This patch addresses this issue by making the slave thread also
check whether the key is active or not before actually using it.
Network error happened here, but it can be caused by CR_CONNECTION_ERROR,
CR_CONN_HOST_ERROR, CR_SERVER_GONE_ERROR, CR_SERVER_LOST, ER_CON_COUNT_ERROR,
and ER_SERVER_SHUTDOWN. We just check CR_SERVER_LOST here, so the test fails.
To fix the problem, check all errors that can be cause by the master shutdown.
Invalid (old?) table or database name in logs
Problem was still not completely fixed, due to
qouting.
This is the server side only fix (in explain_filename),
the change from filename_to_tablename to use explain_filename
in the InnoDB code must be done before the bug is
fixed.
- Create the "dummy" thread joinable and wait for it to
exit before continuing in 'my_thread_global_init'
- This way we know that the pthread library is initialized
by one thread only
when compiled with Sun Studio compiler).
The thing is that Sun Studio compiler calls destructor of stack
objects when pthread_exit() is called. That triggered an assertion
in DBUG_ENTER()/DBUG_RETURN() validation logic (if DBUG_ENTER() is
used in the beginning of function, all returns should be replaced
by DBUG_RETURN/DBUG_VOID_RETURN macros).
A fix is to explicitly use DBUG_LEAVE macro.
value from the index (PRIMARY)
With the fix for BUG#46760, we correctly flag the presence of row_type
only when it's actually changed and enables the FAST ALTER TABLE which was
disabled with the BUG#39200.
So the changes made by BUG#46760 makes MySQL data dictionaries to be out of
sync but they are handled already by InnoDB with this BUG#44030.
The test was originally written to handle this but we requested Innodb to
update the test as the data dictionaries were in sync after the fix for
BUG#39200.
Adjusting the innodb-autoinc testcase as mentioned in the comments.
The "socket" variable is not available on Windows even though
the --socket option can be used to specify the pipe name for
local connections that use a named pipe.
The solution is to ensure that the variable is always defined.
checksum)"
The problem was that checksum of GEOMETRY type used memory addresses
in the computation, making it un-repeatable thus useless.
(This patch is a backport from 6.0 branch)
Despite copying the value of the old table's row type
we don't always have to mark row type as being specified.
Innodb uses this to check if it can do fast ALTER TABLE
or not.
Fixed by correctly flagging the presence of row_type
only when it's actually changed.
Added a test case for 39200.
query
The fix for bug 46749 removed the check for OUTER_REF_TABLE_BIT
and substituted it for a check on the presence of
Item_ident::depended_from.
Removing it altogether was wrong : OUTER_REF_TABLE_BIT should
still be checked in addition to depended_from (because it's not
set in all cases and doesn't contradict to the check of depended_from).
Fixed by returning the old condition back as a compliment to the
new one.
But there is no Last_IO_Error reported.
On the master, if a binary log event is larger than max_allowed_packet,
ER_MASTER_FATAL_ERROR_READING_BINLOG and the specific reason of this error is
sent to a slave when it requests a dump from the master, thus leading
the I/O thread to stop.
On a slave, the I/O thread stops when receiving a packet larger than max_allowed_packet.
In both cases, however, there was no Last_IO_Error reported.
This patch adds code to report the Last_IO_Error and exact reason before stopping the
I/O thread and also reports the case the out memory pops up while
handling packets from the master.
Solaris binary packages should be compiled with '-g0', not '-g'
The main fix for this is done in the build tools,
but in the sources it affects "configure.in"
which sets "DEBUG_CXXFLAGS" to be used in all debug builds.
Option "--without-server" still not working in 5.1
The general approach is to make sure that source files
which require thread support are only compiled if the build
really needs thread support,
which means when the server is built or a thread-safe client
library.
This required several changes:
- Make sure the subdirectories "storage/" and "plugin/" are
only processed if the server is built, not ifclient-only.
- Make the compilation of some modules which inherently
require threading depend on thread supportin the build.
- Separate the handling of threading in "configure.in" from
that of server issues, threading is also needed in a
non-server build of a thread-safe client library.
Also, "libdbug" must get built even in a client-only build,
so "dbug/" must be in the list of client directories.
In addition, calls to thread functions in source files which
can be built without thread support must use the wrapper
functions which handle the non-threaded build.
So the modules "client/mysqlimport.c" and "client/mysqlslap.c"
must call "my_thread_end()" only via "mysql_thread_end()".
"insert into.. select * from"
When inserting into a partitioned table using 'insert into
<target> select * from <src>', read_buffer_size bytes of memory
are allocated for each partition in the target table.
This resulted in large memory consumption when the number of
partitions are high.
This patch introduces a new method which tries to estimate the
buffer size required for each partition and limits the maximum
buffer size used to maximum of 10 * read_buffer_size,
11 * read_buffer_size in case of monotonic partition functions.
When parsing the service installation parameter in
default_service_handling() make sure the value of the
optional parameter doesn't overwrite it's name.
1. Fixes BUG#44030 - Error: (1500) Couldn't read the MAX(ID) autoinc value
from the index (PRIMARY)
2. Disables the innodb-autoinc test for innodb plugin temporarily.
The testcase for this bug has different result file for InnoDB plugin.
Should add the testcase to Innodb suite with a different result file.
Detailed revision comments:
r5243 | sunny | 2009-06-04 03:17:14 +0300 (Thu, 04 Jun 2009) | 14 lines
branches/5.1: When the InnoDB and MySQL data dictionaries go out of sync, before
the bug fix we would assert on missing autoinc columns. With this fix we allow
MySQL to open the table but set the next autoinc value for the column to the
MAX value. This effectively disables the next value generation. INSERTs will
fail with a generic AUTOINC failure. However, the user should be able to
read/dump the table, set the column values explicitly, use ALTER TABLE to
set the next autoinc value and/or sync the two data dictionaries to resume
normal operations.
Fix Bug#44030 Error: (1500) Couldn't read the MAX(ID) autoinc value from the
index (PRIMARY)
rb://118
r5252 | sunny | 2009-06-04 10:16:24 +0300 (Thu, 04 Jun 2009) | 2 lines
branches/5.1: The version of the result file checked in was broken in r5243.
r5259 | vasil | 2009-06-05 10:29:16 +0300 (Fri, 05 Jun 2009) | 7 lines
branches/5.1:
Remove the word "Error" from the printout because the mysqltest suite
interprets it as an error and thus the innodb-autoinc test fails.
Approved by: Sunny (via IM)
r5466 | vasil | 2009-07-02 10:46:45 +0300 (Thu, 02 Jul 2009) | 6 lines
branches/5.1:
Adjust the failing innodb-autoinc test to conform to the latest behavior
of the MySQL code. The idea and the comment in innodb-autoinc.test come
from Sunny.