Commit graph

59 commits

Author SHA1 Message Date
Marko Mäkelä
e4a7c15dd6 Merge 10.2 into 10.3 2021-10-21 13:41:04 +03:00
Thirunarayanan Balathandayuthapani
8ce8c269f4 MDEV-19522 InnoDB commit fails when FTS_DOC_ID value is greater than 4294967295
InnoDB commit fails when consecutive FTS_DOC_ID value
is greater than 4294967295.
Fix is that InnoDB should remove the delta FTS_DOC_ID
value limitations and fts should encode 8 byte value,
remove FTS_DOC_ID_MAX_STEP variable. Replaced the
fts0vlc.ic file with fts0vlc.h

fts_encode_int(): Should be able to encode 10 bytes value

fts_get_encoded_len(): Should get the length of the value
which has 10 bytes

fts_decode_vlc(): Add debug assertion to verify the maximum
length allowed is 10.

mach_read_uint64_little_endian(): Reads 64 bit stored in
little endian format

Added a unit test case which check for minimum and maximum
value to do the fts encoding
2021-10-21 12:56:59 +03:00
Marko Mäkelä
e3d692aa09 Merge 10.2 into 10.3 2020-10-22 08:26:28 +03:00
Marko Mäkelä
46890349bf Cleanup: Remove fts_t::bg_threads_mutex, fts_t::bg_threads
The unused fts_t::bg_threads was added in
mysql/mysql-server@4b1049625c.

Any usage of fts_t::bg_threads_mutex was removed in
mysql/mysql-server@33c2404b39.
2020-10-02 08:36:50 +03:00
Marko Mäkelä
cbcb4ecabb Merge 10.2 into 10.3 2020-09-21 11:04:04 +03:00
Thirunarayanan Balathandayuthapani
75e82f71f1 MDEV-18867 Long Time to Stop and Start
fts_drop_orphaned_tables() takes long time to remove the orphaned
FTS tables. In order to reduce the time, do the following:

- Traverse fil_system.space_list and construct a set of
table_id,index_id of all FTS_*.ibd tablespaces.
- Traverse the sys_indexes table and ignore the entry
from the above collection if it exist.
- Existing elements in the collection can be considered as
orphaned fts tables. construct the table name from
(table_id,index_id) and invoke fts_drop_tables().
- Removed DICT_TF2_FTS_AUX_HEX_NAME flag usage from upgrade.
- is_aux_table() in dict_table_t to check whether the given name
is fts auxiliary table
fts_space_set_t is a structure to store set of parent table id
and index id
- Remove unused FTS function in fts0fts.cc
- Remove the fulltext index in row_format_redundant test case.
Because it deals with the condition that SYS_TABLES does have
corrupted entry and valid entry exist in SYS_INDEXES.
2020-09-10 14:10:26 +05:30
Marko Mäkelä
1df1a63924 Merge 10.2 into 10.3 2020-07-02 06:17:51 +03:00
Thirunarayanan Balathandayuthapani
e30c4cfc7a MDEV-22811 DDL fails to drop and re-create FTS index
Problem:
========
- InnoDB clears the fts resource when last FTS index is being dropped
if the table has user defined FTS_DOC_ID. While creating the new fts
index, InnoDB expects to have FTS resources.

Fix:
===
fts_drop_index(): Removed the fts resource clear.

fts_clear_all(): Clear the fts resource when there are no new fts
index to be added.

commit_cache_norebuild(), row_merge_drop_indexes():
Tries to call fts resource after removing associated fts index
from table object
2020-06-18 15:49:39 +05:30
Marko Mäkelä
1fbdcada73 Merge 10.2 into 10.3 2020-04-28 22:29:13 +03:00
Marko Mäkelä
547cb280b8 Merge 10.1 into 10.2 2020-04-28 19:39:40 +03:00
Marko Mäkelä
7041807476 MDEV-22393 Corruption for SET GLOBAL innodb_ string variables
Several MYSQL_SYSVAR_STR parameters that employ both a validate
function callback fail to copy the string for saving the
validated value. The affected variables include the following:

innodb_ft_aux_table
innodb_ft_server_stopword_table
innodb_ft_user_stopword_table
innodb_buffer_pool_filename

The test case is an enhanced version of
mysql/mysql-server@0b0c30641f
and the code changes are inspired by their fixes.

We are also importing and adjusting the test innodb_fts.stopword
to get coverage for the variable innodb_ft_user_stopword_table.

buf_dump(), buf_load(): Protect srv_buf_dump_filename with
LOCK_global_system_variables.

fts_load_user_stopword(): Minor cleanup

fts_load_stopword(): Remove the parameter global_stopword_table.

innobase_fts_load_stopword(): Protect innodb_server_stopword_table
against concurrent SET GLOBAL.
2020-04-28 16:09:07 +03:00
Oleksandr Byelkin
55b2281a5d Merge branch '10.2' into 10.3 2019-10-31 10:58:06 +01:00
Marko Mäkelä
d752a97ebb Merge 10.1 to 10.2 2019-10-25 17:33:39 +03:00
Thirunarayanan Balathandayuthapani
a41d429765 MDEV-20621 FULLTEXT INDEX activity causes InnoDB hang
- fts_optimize_thread() uses dict_table_t object instead of table id.
So that it doesn't acquire dict_sys->mutex. It leads to remove the
hang of dict_sys->mutex between fts_optimize_thread() and other threads.

- in_queue to indicate whether the table is in fts_optimize_queue. It
is protected by fts_optimize_wq->mutex to avoid any race condition.

- fts_optimize_init() adds the fts table to the fts_optimize_wq
2019-10-25 16:27:41 +03:00
Marko Mäkelä
c016ea660e Merge 10.2 into 10.3 2019-09-23 10:25:34 +03:00
Marko Mäkelä
bb4214272a Merge 10.1 into 10.2 2019-09-18 16:24:48 +03:00
Marko Mäkelä
a624b99f91 Remove an unused declaration 2019-09-18 16:10:03 +03:00
Thirunarayanan Balathandayuthapani
8a79fa0e4d MDEV-19529 InnoDB hang on DROP FULLTEXT INDEX
Problem:
=======
  During dropping of fts index, InnoDB waits for fts_optimize_remove_table()
and it holds dict_sys->mutex and dict_operaiton_lock even though the
table id is not present in the queue. But fts_optimize_thread does wait
for dict_sys->mutex to process the unrelated table id from the slot.

Solution:
========
  Whenever table is added to fts_optimize_wq, update the fts_status
of in-memory fts subsystem to TABLE_IN_QUEUE. Whenever drop index
wants to remove table from the queue, it can check the fts_status
to decide whether it should send the MSG_DELETE_TABLE to the queue.

Removed the following functions because these are all deadcode.
dict_table_wait_for_bg_threads_to_exit(),
fts_wait_for_background_thread_to_start(),fts_start_shutdown(), fts_shudown().
2019-09-18 13:22:08 +05:30
Marko Mäkelä
fdef9f9b89 Merge 10.2 into 10.3 2019-07-25 15:31:11 +03:00
Marko Mäkelä
a7e9395f9d fts_sync_table(), fts_sync() dead code removal
fts_sync(): Remove the constant parameter has_dict=false.

fts_sync_table(): Remove the constant parameter has_dict=false,
and the redundant parameter unlock_cache = !wait.
Make wait=true the default parameter.
2019-07-25 13:34:36 +03:00
Marko Mäkelä
874f8f30f2 Merge 10.2 into 10.3 2019-05-14 17:25:25 +03:00
Marko Mäkelä
be85d3e61b Merge 10.2 into 10.3 2019-05-14 17:18:46 +03:00
Marko Mäkelä
50999738ea Merge 10.1 into 10.2 2019-05-13 18:48:28 +03:00
Marko Mäkelä
26a14ee130 Merge 10.1 into 10.2 2019-05-13 17:54:04 +03:00
Marko Mäkelä
2647fd101d MDEV-19445 heap-use-after-free related to innodb_ft_aux_table
Try to fix the race conditions between
SET GLOBAL innodb_ft_aux_table = ...;
and access to the INFORMATION_SCHEMA tables that depend on
this variable.

innodb_ft_aux_table: Replaces
fts_internal_tbl_name,fts_internal_tbl_name2. Just store the
user-specified parameter as is.

innodb_ft_aux_table_id: The table_id corresponding to
SET GLOBAL innodb_ft_aux_table, or 0 if the table does not exist
or does not contain FULLTEXT INDEX. If the table is renamed later,
the INFORMATION_SCHEMA tables will continue to refer to the table.
If the table is dropped or rebuilt, the INFORMATION_SCHEMA tables
will not find the table.
2019-05-13 17:16:42 +03:00
Marko Mäkelä
c7c54ce606 fts_doc_ids_free(): Define inline 2019-05-13 11:32:20 +03:00
Oleksandr Byelkin
c51f85f882 Merge branch '10.2' into 10.3 2019-05-12 17:20:23 +02:00
Vicențiu Ciorbaru
c0ac0b8860 Update FSF address 2019-05-11 19:25:02 +03:00
Marko Mäkelä
b2f3755c8e Merge 10.1 into 10.2 2019-05-10 08:02:21 +03:00
Marko Mäkelä
f92749ed36 MDEV-18220: heap-use-after-free in fts_get_table_name_prefix()
fts_table_t::parent: Remove the redundant field. Refer to
table->name.m_name instead.

fts_update_sync_doc_id(), fts_update_next_doc_id(): Remove
the redundant parameter table_name.

fts_get_table_name_prefix(): Access the dict_table_t::name.
FIXME: Ensure that this access is always covered by
dict_sys->mutex.
2019-05-10 07:57:01 +03:00
Marko Mäkelä
0abd2766b1 Merge 10.2 into 10.3
Also, related to MDEV-15522, MDEV-17304, MDEV-17835,
remove the Galera xtrabackup tests, because xtrabackup never worked
with MariaDB Server 10.3 due to InnoDB redo log format changes.
2018-11-30 09:38:56 +02:00
Marko Mäkelä
447e493179 Remove some unnecessary InnoDB #include 2018-11-29 12:53:44 +02:00
Marko Mäkelä
fd58bb71e2 Merge 10.2 into 10.3 2018-11-19 18:45:53 +02:00
Marko Mäkelä
ff88e4bb8a Remove many redundant #include from InnoDB 2018-11-19 11:42:14 +02:00
Marko Mäkelä
df563e0c03 Merge 10.2 into 10.3
main.derived_cond_pushdown: Move all 10.3 tests to the end,
trim trailing white space, and add an "End of 10.3 tests" marker.
Add --sorted_result to tests where the ordering is not deterministic.

main.win_percentile: Add --sorted_result to tests where the
ordering is no longer deterministic.
2018-11-06 09:40:39 +02:00
Marko Mäkelä
32062cc61c Merge 10.1 into 10.2 2018-11-06 08:41:48 +02:00
Thirunarayanan Balathandayuthapani
1dacd5f299 MDEV-12547: InnoDB FULLTEXT index has too strict innodb_ft_result_cache_limit max limit
- Backported the MYSQL_SYSVAR_SIZE_T to 10.0
- The parameter innodb_ft_result_cache_limit was only 32 bits wide
also on 64-bit systems. Make it size_t, so that it will be 64 bits
on 64-bit systems.
- Added a test case that show how innodb_ft_result_cache_limit variables
behaves in 32bit and 64 bit system.
2018-10-16 13:02:50 +05:30
Marko Mäkelä
05459706f2 Merge 10.2 into 10.3 2018-08-03 15:57:23 +03:00
Marko Mäkelä
ef3070e997 Merge 10.1 into 10.2 2018-08-02 08:19:57 +03:00
Marko Mäkelä
e52315a4a2 MDEV-16855 Fix fts_sync_synchronization in InnoDB
This is a backport of the following fix from MySQL 5.7.23.
Some code refactoring has been omitted, and the test case has
been adapted to MariaDB.

commit 7a689acaa65e9d602575f7aa53fe36a64a07460f
Author: Krzysztof Kapuścik <krzysztof.kapuscik@oracle.com>
Date:   Tue Mar 13 12:34:03 2018 +0100

Bug#27082268 Invalid FTS sync synchronization

The fix closes two issues:
Bug #27082268 - INNODB: FAILING ASSERTION: SYM_NODE->TABLE != NULL DURING FTS SYNC
Bug #27095935 - DEADLOCK BETWEEN FTS_DROP_INDEX AND FTS_OPTIMIZE_SYNC_TABLE

Both issues were related to a FTS cache sync being done during
operations that perfomed DDL actions on internal FTS tables
(ALTER TABLE, TRUNCATE). In some cases the FTS tables and/or
internal cache structures could get removed while still being
used to perform FTS synchronization leading to crashes. In other
the sync operations could not get finishes as it was waiting for
dict lock which was taken by thread waiting for the background
sync to be finished.

The changes done includes:
- Stopping background operations during ALTER TABLE and TRUNCATE.
- Removal of unused code in FTS.
- Cleanup of FTS sync related code to make it more readable and
easier to maintain.

RB#18262
2018-07-30 18:06:30 +03:00
Marko Mäkelä
2b27ac8282 Fix many -Wunused-parameter
Remove unused InnoDB function parameters and functions.

i_s_sys_virtual_fill_table(): Do not allocate heap memory.

mtr_is_block_fix(): Replace with mtr_memo_contains().

mtr_is_page_fix(): Replace with mtr_memo_contains_page().
2018-05-01 16:52:19 +03:00
Marko Mäkelä
428e02895b MDEV-12266: Remove dict_index_t::table_name
Replace index->table_name with index->table->name.
2018-03-29 20:47:37 +03:00
Marko Mäkelä
0ba6aaf030 MDEV-11415 Remove excessive undo logging during ALTER TABLE…ALGORITHM=COPY
If a crash occurs during ALTER TABLE…ALGORITHM=COPY, InnoDB would spend
a lot of time rolling back writes to the intermediate copy of the table.
To reduce the amount of busy work done, a work-around was introduced in
commit fd069e2bb3 in MySQL 4.1.8 and 5.0.2,
to commit the transaction after every 10,000 inserted rows.

A proper fix would have been to disable the undo logging altogether and
to simply drop the intermediate copy of the table on subsequent server
startup. This is what happens in MariaDB 10.3 with MDEV-14717,MDEV-14585.
In MariaDB 10.2, the intermediate copy of the table would be left behind
with a name starting with the string #sql.

This is a backport of a bug fix from MySQL 8.0.0 to MariaDB,
contributed by jixianliang <271365745@qq.com>.

Unlike recent MySQL, MariaDB supports ALTER IGNORE. For that operation
InnoDB must for now keep the undo logging enabled, so that the latest
row can be rolled back in case of an error.

In Galera cluster, the LOAD DATA statement will retain the existing
behaviour and commit the transaction after every 10,000 rows if
the parameter wsrep_load_data_splitting=ON is set. The logic to do
so (the wsrep_load_data_split() function and the call
handler::extra(HA_EXTRA_FAKE_START_STMT)) are joint work
by Ji Xianliang and Marko Mäkelä.

The original fix:

Author: Thirunarayanan Balathandayuthapani <thirunarayanan.balathandayuth@oracle.com>
Date:   Wed Dec 2 16:09:15 2015 +0530

Bug#17479594 AVOID INTERMEDIATE COMMIT WHILE DOING ALTER TABLE ALGORITHM=COPY

Problem:

During ALTER TABLE, we commit and restart the transaction for every
10,000 rows, so that the rollback after recovery would not take so long.

Fix:

Suppress the undo logging during copy alter operation. If fts_index is
present then insert directly into fts auxiliary table rather
than doing at commit time.

ha_innobase::num_write_row: Remove the variable.

ha_innobase::write_row(): Remove the hack for committing every 10000 rows.

row_lock_table_for_mysql(): Remove the extra 2 parameters.

lock_get_src_table(), lock_is_table_exclusive(): Remove.

Reviewed-by: Marko Mäkelä <marko.makela@oracle.com>
Reviewed-by: Shaohua Wang <shaohua.wang@oracle.com>
Reviewed-by: Jon Olav Hauglid <jon.hauglid@oracle.com>
2018-01-30 20:24:23 +02:00
Sergei Golubchik
e0a1c745ec Merge branch '10.1' into 10.2 2017-10-24 14:53:18 +02:00
Marko Mäkelä
3bc094d32a Remove dead code for pushing down LIMIT to InnoDB FULLTEXT INDEX queries
MySQL 5.7 added code to push down the LIMIT to fulltext search
in InnoDB:

commit 2cd0ebf97e1b265e2282d7ceb5d8dfb663ffc48f
Author: Thirunarayanan Balathandayuthapani <thirunarayanan.balathandayuth@oracle.com>
Date:   Fri May 27 13:49:28 2016 +0530

    Bug #22709692   FTS QUERY EXCEEDS RESULT CACHE LIMIT

The code was disabled when MySQL 5.7.9 was merged to MariaDB 10.2.2.

We shall remove the disabled code and unnecessary variables.
2017-10-18 09:07:53 +03:00
Marko Mäkelä
172cc70bf8 MDEV-13446 fts_create_doc_id() unnecessarily allocates 8 bytes for every inserted row
fts_create_doc_id(): Remove.

row_mysql_convert_row_to_innobase(): Implement the logic of
fts_create_doc_id(). Reuse a buffer for the hidden FTS_DOC_ID.

row_get_prebuilt_insert_row(): Allocate a buffer for the hidden
FTS_DOC_ID at the end of prebuilt->ins_upd_rec_buff.
2017-10-09 12:18:12 +03:00
Shaohua Wang
1a5ca702b1 Followup: BUG#23479595 SEGMENTATION FAULT WHEN SELECT FTS INDEX TABLES IN INFORMATION SCHEMA
BUG#23742339 FAILING ASSERTION: SYM_NODE->TABLE != NULL

Analysis: When we access fts aux tables in information schema,the
fts aux tables are dropped by DROP DATABASE in another session.

Solution: Drop parent table if it's a fts aux table, and drop
table will drop fts aux tables together.

Reviewed-by: Jimmy Yang <jimmy.yang@oracle.com>
RB: 13264
2017-04-24 14:53:59 +03:00
Shaohua Wang
9ce1ea6f51 BUG#24009272 SEGFAULT WITH CREATE+SELECT FROM IS+DROP FTS TABLE CONCURRENTLY
Analysis:
When we access fts_internal_tbl_name in i_s_fts_config_fill (),
it can be set to NULL by another session.

Solution:
Define fts_internal_tbl_name2 for global variable innodb_ft_aux_table,
if it's NULL, set fts_internal_tbl_name to "default".

Reviewed-by: Jimmy Yang <jimmy.yang@oracle.com>
RB: 13401
2017-04-24 14:53:22 +03:00
Marko Mäkelä
97acc4a1c3 MDEV-12270 Port MySQL 8.0 Bug#21141390 REMOVE UNUSED FUNCTIONS AND CONVERT GLOBAL SYMBOLS TO STATIC
InnoDB defines some functions that are not called at all.
Other functions are called, but only from the same compilation unit.

Remove some function declarations and definitions, and add 'static'
keywords. Some symbols must be kept for separately compiled tools,
such as innochecksum.
2017-03-17 12:48:50 +02:00
Marko Mäkelä
732672c304 MDEV-11233 CREATE FULLTEXT INDEX with a token longer than 127 bytes
crashes server

This bug is the result of merging the Oracle MySQL follow-up fix
BUG#22963169 MYSQL CRASHES ON CREATE FULLTEXT INDEX
without merging the base bug fix:
Bug#79475 Insert a token of 84 4-bytes chars into fts index causes
server crash.

Unlike the above mentioned fixes in MySQL, our fix will not change
the storage format of fulltext indexes in InnoDB or XtraDB
when a character encoding with mbmaxlen=2 or mbmaxlen=3
and the length of a word is between 128 and 84*mbmaxlen bytes.
The Oracle fix would allocate 2 length bytes for these cases.

Compatibility with other MySQL and MariaDB releases is ensured by
persisting the used maximum length in the SYS_COLUMNS table in the
InnoDB data dictionary.

This fix also removes some unnecessary strcmp() calls when checking
for the legacy default collation my_charset_latin1
(my_charset_latin1.name=="latin1_swedish_ci").

fts_create_one_index_table(): Store the actual length in bytes.
This metadata will be written to the SYS_COLUMNS table.

fts_zip_initialize(): Initialize only the first byte of the buffer.
Actually the code should not even care about this first byte, because
the length is set as 0.

FTX_MAX_WORD_LEN: Define as HA_FT_MAXCHARLEN * 4 aka 336 bytes,
not as 254 bytes.

row_merge_create_fts_sort_index(): Set the actual maximum length of the
column in bytes, similar to fts_create_one_index_table().

row_merge_fts_doc_tokenize(): Remove the redundant parameter word_dtype.
Use the actual maximum length of the column. Calculate the extra_size
in the same way as row_merge_buf_encode() does.
2017-01-27 10:19:39 +02:00