Problem : The basic problem is the way the thread sleeps in mysql-5.5 and also in mysql-5.1
when we execute a stop slave on windows platform.
On windows platform if the stop slave is executed after the master dies, we have
this long wait before the stop slave return a value. This is because there is a
sleep of the thread. The sleep is uninterruptable in the two above version,
which was fixed by Davi patch for the BUG#11765860 for mysql-trunk. Backporting
his patch for mysql-5.5 fixes the problem.
Solution : A new pair of mutex and condition variable is introduced to synchronize thread
sleep and finalization. A new mutex is required because the slave threads are
terminated while holding the slave thread locks (run_lock), which can not be
relinquished during termination as this would affect the lock order.
and cryptic error 1126 message
The problem was that dlopen() related code was using just a subset
of the path normalization routines used in other places.
Fixed the expansion of the pre-dlopen() behavior for plugins and UDFs
to use a platform-dependent consistent encoding of the paths.
Fixed the error dlopen() error handling to take the correct error message
and strip off the trailing newline character(s).
Fixed tests to do a platform independent replace of directories and to
account for the traling slash.
Added a global read-only option slow-start-timeout to control the
Windows service control manager's service start timeout, that was
currently hard-coded to be 15 seconds.
The default of the new option is 15 seconds.
The timeout can also be set to 0 (to mean no timeout applicable).
BIN LOG HAS BEEN MOVED
When moving the binary/relay log files from one location to
another and restarting the server with a different log-bin or
relay-log paths, would cause the startup process to abort. The
root cause was that the server would not be able to find the log
files because it would consider old paths for entries in the
index file instead of the new location. What's even worse, the
relative paths would not be considered relative to the path
provided in log-bin and relay-log, but to mysql_data_dir.
We fix the cases where the server contains relative paths. When
the server is reading from the index file, it checks whether the
entry contains relative paths. If it does, we replace it with the
absolute path set in log-bin/relay-log option. Absolute paths
remain unchanged and the index must be manually edited to
consider the new log-bin and/or relay-log path (this should be
documented). This is a fix for a GA version, that does not break
behavior (that much).
For development versions, we should go with Zhenxing's approach
that removes paths altogether from index files.
TOOLS
Backport a fix for Bug 57094 from 5.5.
The following revision was backported:
# revision-id: alexander.nozdrin@oracle.com-20101006150613-ls60rb2tq5dpyb5c
# parent: bar@mysql.com-20101006121559-am1e05ykeicwnx48
# committer: Alexander Nozdrin <alexander.nozdrin@oracle.com>
# branch nick: mysql-5.5-bugteam-bug57094
# timestamp: Wed 2010-10-06 19:06:13 +0400
# message:
# Fix for Bug 57094 (Copyright notice incorrect?).
#
# The fix is to:
# - introduce ORACLE_WELCOME_COPYRIGHT_NOTICE define to have a single place
# to specify copyright notice;
# - replace custom copyright notices with ORACLE_WELCOME_COPYRIGHT_NOTICE
# in programs.
GCC 4.6 has new -Wunused-but-set-variable flag, which is enabled
by -Wall, that causes GCC to emit a warning whenever a local variable
is assigned to, but otherwise unused (aside from its declaration).
Since the maintainer mode uses -Wall and -Werror, source code which
triggers these warnings will be rejected. That is, these warnings
become hard errors.
The solution is to fix the code which triggers these specific warnings.
In most of the cases, this is a welcome cleanup as code which triggers
this warning is probably dead anyway.
This is the 5.1 version of the fix.
Need to free the memory allocated by the option parsing code for empty
strings when resetting the pointer to NULL.
No test case needed, as the existing ones already cover this path.
FAIL IN EMBEDDED SERVER
FreeBSD 64 bit needs the FP_X_DNML to fpsetmask() to prevent exceptions from
propagating into mysql (as a threaded application).
However fpsetmask() itself is deprecated in favor of fedisableexcept().
1. Fixed the #ifdef to check for FP_X_DNML instead of i386.
2. Added a configure.in check for fedisableexcept() and, if present,
this function is called insted of the fpsetmask().
No need for new tests, as the existing tests cover this already.
Removed the affected tests from the experimental list.
Problem: MYSQL_BIN_LOG::reset_logs acquires mutexes in wrong order.
The correct order is first LOCK_thread_count and then LOCK_log. This function
does it the other way around. This leads to deadlock when run in parallel
with a thread that takes the two locks in correct order. For example, a thread
that disconnects will take the locks in the correct order.
Fix: change order of the locks in MYSQL_BIN_LOG::reset_logs:
first LOCK_thread_count and then LOCK_log.
USING '..' ON WINDOWS
Backport of the fix to 5.0 (to be null-merged to 5.1).
Moved the test into the main test suite.
Made mysql-test-run.pl to not use symlinks for sdtdata as the symlinks
are now properly recognized by secure_file_priv.
Made sure the paths in load_file(), LOAD DATA and SELECT .. INTO OUTFILE
that are checked against secure_file_priv in a correct way similarly to 5.1
by the extended is_secure_file_path() backport before the comparison.
Added an extensive test with all the variants of upper/lower case,
slash/backslash and case sensitivity.
Added few comments to the code.
ARE NOT BEING HONORED
max_allowed_packet works in conjunction with net_buffer_length.
max_allowed_packet is an upper bound of net_buffer_length.
So it doesn't make sense to set the upper limit lower than the value.
Added a warning (using ER_UNKNOWN_ERRROR and a specific message)
when this is done (in the log at startup and when setting either
max_allowed_packet or the net_buffer_length variables)
Added a test case.
Fixed several tests that broke the above rule.
The problem was that server didn't check resulting size of prepared
statement argument which was set using mysql_send_long_data() API.
By calling mysql_send_long_data() several times it was possible
to create overly big string and thus force server to allocate
memory for it. There was no way to limit this allocation.
The solution is to add check for size of result string against
value of max_long_data_size start-up parameter. When intermediate
string exceeds max_long_data_size value an appropriate error message
is emitted.
We can't use existing max_allowed_packet parameter for this purpose
since its value is limited by 1GB and therefore using it as a limit
for data set through mysql_send_long_data() API would have been an
incompatible change. Newly introduced max_long_data_size parameter
gets value from max_allowed_packet parameter unless its value is
specified explicitly. This new parameter is marked as deprecated
and will be eventually replaced by max_allowed_packet parameter.
Value of max_long_data_size parameter can be set only at server
startup.
INSTALLATION
When starting mysqld as an MS Windows NT service, it crashed
with "Error 1067: The process terminated unexpectedly".
The problem is that thread local variables are not allocated
and initialized properly when started as a service. When the
server is started as a regular executable, the problem does
not occur.
Analysis showed that this is a regression after the patch for
Bug#11765237/Bug#11763065. Before, the thread local storage
was initialized by the call chain:
win_main->my_basic_init->my_thread_basic_global_init->
my_thread_init
When the my_init() structure was changed, this initialization
was moved from win_main to mysqld_main. When started as
a service win_main is run in a separate thread, which does
not have mysqld_main in its call path, so my_thread_init
is never called for this thread.
Added a call to my_thread_init / my_thread_end in the service
handler function, which solves the problem.
Before this fix, all the performance schema instrumentation for both the binary log
and the relay log would use the following instruments:
- wait/io/file/sql/binlog
- wait/io/file/sql/binlog_index
- wait/synch/mutex/sql/MYSQL_BIN_LOG::LOCK_index
- wait/synch/cond/sql/MYSQL_BIN_LOG::update_cond
This instrumentation is too general and can be more specific.
With this fix, the binlog instrumentation is identical,
and the relay log instrumentation is changed to:
- wait/io/file/sql/relaylog
- wait/io/file/sql/relaylog_index
- wait/synch/mutex/sql/MYSQL_RELAY_LOG::LOCK_index
- wait/synch/cond/sql/MYSQL_RELAY_LOG::update_cond
With this change, the performance instrumentation for the binary log and the relay log,
which share the same structure but have different uses, is more detailed.
This is especially important for hosts in the middle of a replication chain,
that are both masters (binlog) and slaves (relaylog).
Bug#11763065 - 55730: KILL_SERVER() CALLS SETEVENT ON A NULL
HANDLE, SMEM_EVENT_CONNECT_REQUEST
Application Verifier is a Microsoft tool used for
detecting certain classes of programming errors.
In particular, MS Windows OS resource usage is
monitored for wrong usage (handles, thread local
storage, critical sections, ...)
In MySQL 5.5.x, an error was introduced where an
object on thread local storage was used before the
TLS and the object was created.
The fix has been to move the mysys initialization
to an earlier stage in the boot process when built for
Windows. For non-win builds, the init already happens
early.
Some un-tangling of calls to my_init(), my_basic_init()
and my_thread_global_init() was done. There is no
longer a need to do init in steps, so the full my_init()
is called instead of my_init_basic().
In addition, Bug#11763065 was fixed. The event handle
'smem_event_connect_request' is only created if
'opt_enable_shared_memory' is set. When killing the
server, an event was flagged on the handle
unconditionally. Added a test, so it will only be
flagged if created.
handling.
The problem was that parsing of nested regular expression involved
recursive calls. Such recursion didn't take into account the amount of
available stack space, which ended up leading to stack overflow crashes.