numbers into char fields" and bug #12860 "Difference in zero padding of
exponent between Unix and Windows"
Rewrote the code that determines what 'precision' argument should be
passed to sprintf() to fit the string representation of the input number
into the field.
We get finer control over conversion by pre-calculating the exponent, so
we are able to determine which conversion format, 'e' or 'f', will be
used by sprintf().
We also remove the leading zero from the exponent on Windows to make it
compatible with the sprintf() output on other platforms.
No warning was generated when a TIMESTAMP with a non-zero time part
was converted to a DATE value. This caused index lookup to assume
that this is a valid conversion and was returning rows that match
a comparison between a TIMESTAMP value and a DATE keypart.
Fixed by generating a warning on such a truncation.
Fixed the usage of spatial data (and Point in specific) with
non-spatial indexes.
Several problems :
- The length of the Point class was not updated to include the
spatial reference system identifier. Fixed by increasing with 4
bytes.
- The storage length of the spatial columns was not accounting for
the length that is prepended to it. Fixed by treating the
spatial data columns as blobs (and thus increasing the storage
length)
- When creating the key image for comparison in index read wrong
key image was created (the one needed for and r-tree search,
not the one for b-tree/other search). Fixed by treating the
spatial data columns as blobs (and creating the correct kind of
image based on the index type).
The change_to_use_tmp_fields function leaves the orig_table member of an
expression's tmp table field filled for the new Item_field being created.
Later orig_table is used by the Field::make_field function to provide some
info about original table and field name to a user. This is ok for a field
but for an expression it should be empty.
The change_to_use_tmp_fields function now resets orig_table member of
an expression's tmp table field to prevent providing a wrong info to a user.
The Field::make_field function now resets the table_name and the org_col_name
variables when the orig_table is set to 0.
MySQL replicates the time zone only when operations that involve
it are performed. This is controlled by a flag. But this flag
is set only on successful operation.
The flag must be set also when there is an error that involves
a timezone (so the master would replicate the error to the slaves).
Fixed by moving the setting of the flag before the operation
(so it apples to errors as well).
If a primary key is defined over column c of enum type then
the EXPLAIN command for a look-up query of the form
SELECT * FROM t WHERE c=0
said that the query was with an impossible where condition though the
query correctly returned non-empty result set when the table indeed
contained rows with error empty strings for column c.
This kind of misbehavior was due to a bug in the function
Field_enum::store(longlong,bool) that erroneously returned 1 if
the the value to be stored was equal to 0.
Note that the method
Field_enum::store(const char *from,uint length,CHARSET_INFO *cs)
correctly returned 0 if a value of the error empty string
was stored.
The Field_newdate::store when storing a DATETIME value was returning the
'value was cut' error even if the thd->count_cuted_fields flag is set to
CHECK_FIELD_IGNORE. This made range optimizr think that there is no
appropriate data in the table and thus to return an empty set.
Now the Field_newdate::store function returns conversion error only if the
thd->count_cuted_fields flag isn't set to CHECK_FIELD_IGNORE.
An assertion abort could occur for some grouping queries that employed
decimal user variables with assignments to them.
The problem appeared the constructors of the class Field_new_decimal
because the function my_decimal_length_to_precision did not guarantee
returning decimal precision not greater than DECIMAL_MAX_PRECISION.
Added --with-system-type=<systype> and --with-machine-type=<machtype>
options, to be able to override the one detected, for --version strings
field.cc, field.h, listener.cc:
C++ compatibility change for IBM VisualAge 6 and i5/OS
wrong result for DML
When making key reference buffers over CHAR fields whitespace (0x20)
must be used to fill in the remaining space in the field's buffer.
This is what Field_string::store() does.
Fixed Field_string::get_key_image() to do the same.
ENUM fields internally store their values as integers and may use integer
values as indexes to their values. Invalid values are mapped to zero value.
When storing an empty string the ENUM field fails to find an appropriate value
and tries to convert the provided string to integer. The conversion also
fails and error is returned even if the thd->count_cuted_fields is set to
CHECK_FIELD_IGNORE. This makes the range optimizer wrongly decide that an
impossible range is present.
Now the Field_enum::store() returns error while storing an empty string only
if the thd->count_cuted_fields isn't set to CHECK_FIELD_IGNORE.
When storing a large number to a FLOAT or DOUBLE field with fixed length, it could be incorrectly truncated if the field's length was greater than 31.
This patch also does some code cleanups to be able to reuse code which is common between Field_float::store() and Field_double::store().
Made year 2000 handling more uniform
Removed year 2000 handling out from calc_days()
The above removes some bugs in date/datetimes with year between 0 and 200
Now we get a note when we insert a datetime value into a date column
For default values to CREATE, don't give errors for warning level NOTE
Fixed some compiler failures
Added library ws2_32 for windows compilation (needed if we want to compile with IOCP support)
Removed duplicate typedef TIME and replaced it with MYSQL_TIME
Better (more complete) fix for: Bug#21103 "DATE column not compared as DATE"
Fixed properly Bug#18997 "DATE_ADD and DATE_SUB perform year2K autoconversion magic on 4-digit year value"
Fixed Bug#23093 "Implicit conversion of 9912101 to date does not match cast(9912101 as date)"
INSERT...ON DUPLICATE KEY UPDATE may cause error 1032:
"Can't find record in ..." if we are inserting into
InnoDB table unique index of partial key with
underlying UTF-8 string field.
This error occurs because INSERT...ON DUPLICATE uses a wrong
procedure to copy string fields of multi-byte character sets
for index search.
#27176: Assigning a string to an year column has unexpected results
#26359: Strings becoming truncated and converted to numbers under STRICT mode
Problems:
1. storing a string to an integer field we don't check
if strntoull10rnd() returns MY_ERRNO_EDOM error.
Fix: check for MY_ERRNO_EDOM.
2. storing a string to an year field we use my_strntol() function.
Fix: use strntoull10rnd() instead.
Different set of conditions is used to verify
the validity of index definitions over a GEOMETRY
column in ALTER TABLE and CREATE TABLE.
The difference was on how sub-keys notion validity
is checked.
Fixed by extending the CREATE TABLE condition to
support the cases allowed in ALTER TABLE.
Made the SHOW CREATE TABLE not to display spatial
indexes using the sub-key notion.
If we compare two items A and B, with B being (a constant) of a
larger type, then A gets promoted to B's type for comparison if
it's a constant, function, or CAST() column, but B gets demoted
to A's type if A is a (not explicitly CAST()) column. This is
counter-intuitive and not mandated by the standard.
Disabling optimisation where it would be lossy so field value
will properly get promoted and compared as binary string (rather
than as integers).