When a sessione is closed, all temporary tables of the session are automatically
dropped and are binlogged. But it will be binlogged with wrong database names when
the length of the temporary tables' database names are greater than the
length of the current database name or the current database is not set.
Query_log_event's db_len is forgot to set when Query_log_event's db is set.
This patch wrote code to set db_len immediately after db has set.
- disabled main.innodb_bug47777.test with InnoDB plugin
until fix for plugin is applied.
- disabled main.innodb-autoinc.test (failing)
- re-enabled main.innodb_bug39438.test
- added error message suppression to innodb_bug39438, as
requested by InnoDB/Oracle
- reverted change to main.innodb_bug34300 as plugin specific.
ONLY_FULL_GROUP_BY
Problem was that during checking and preparation of the
partitioining function as a side effect in fix_fields
the full_group_by_flag was changed.
Solution was to set it back to its original value after
calling fix_fields.
Updated patch, to also exclude allow_sum_func from being
affected of fix_fields, as requested by reviewer.
mysql-test/r/partition.result:
Bug#46923: select count(*) from partitioned table fails with
ONLY_FULL_GROUP_BY
Updated result file
mysql-test/t/partition.test:
Bug#46923: select count(*) from partitioned table fails with
ONLY_FULL_GROUP_BY
Extended test case to cover this bug
sql/sql_partition.cc:
Bug#46923: select count(*) from partitioned table fails with
ONLY_FULL_GROUP_BY
Resetting full_group_by_flag and allow_sum_func
back to their original values,
not conflicting with the sql_mode 'ONLY_FULL_GROUP_BY'
The reason for the bug is that mysqtest as well as other client tools
running in test suite (mysqlbinlog, mysqldump) will first try to connect
whatever database has created shared memory with default base name
"MySQL" and use this. (Same effect could be seen on Unix if mtr would
not care to calculate "port" and "socket" parameter).
The fix ensures that all client tools and running in mtr use unique
per-database shared memory base parameters, so there is no possibility
to clash with already installed one. We use socket name for shared memory
base (it's known to be unique). This shared-memory-base is written to the
MTR config file to the [client] and [mysqld] sections. Fix made also made
sure all client tools understand and correctly handle --shared-memory-base.
Prior to this patch it was not the case for mysqltest, mysqlbinlog and
mysql_client_test.
All new connections done from mtr scripts via connect() will by default
set shared-memory-base. And finally, there is a possibility to force
shared memory or pipe connection and overwrite shared memory/pipe base name
from within mtr scripts via optional PIPE or SHM modifier. This functionality
was manually backported from 6.0
(original patch http://lists.mysql.com/commits/74749)
Bug#31621: Windows server hanging during shutdown using named pipes
and idle connection
Problem: when idle pipe connection is forcefully closed with KILL
statement or when the server goes down, thread that is closing connection
would hang infinitely in CloseHandle(). The reason for the hang is that
named pipe operations are performed synchronously. In this mode all IOs
on pipe are serialized, that is CloseHandle() will not abort ReadFile()
in another thread, but wait for ReadFile() to complete.
The fix implements asynchrnous mode for named pipes, where operation of file
are not synchronized. Read/Write operation would fire an async IO and wait for
either IO completion or timeout.
Note, that with this patch timeouts are properly handled for named pipes.
Post-review: Win32 timeout code has been fixed for named pipes and shared
memory. We do not store pointer to NET in vio structure, only the read and
write timeouts.
include/violite.h:
Add pipe_overlapped to Vio structure for async IO for named pipes.
sql-common/client.c:
Use asynchronous pipe IO.
sql/mysqld.cc:
Use asynchronous pipe IO.
vio/vio.c:
-Refactor timeouts for win32 protocols: shared memory and named pipes.
Store read/write timeout in VIO structure, instead of storing pointer
to NET. New function vio_win32_timeout called indirectly via
vio_timeout changes these values.
vio/vio_priv.h:
Remove vio_ignore_timeout.
Add vio_win32_timeout to be used for named pipes and shared memory.
vio/viosocket.c:
Use async IO for named pipes.
After issuing IO, wait for either IO completion, pipe_close_event
or timeout.
Refactor timeouts for named pipe and shared memory.
Detailed revision comments:
r6127 | vasil | 2009-10-30 11:18:25 +0200 (Fri, 30 Oct 2009) | 18 lines
branches/5.1:
Backport c6121 from branches/zip:
------------------------------------------------------------------------
r6121 | sunny | 2009-10-30 01:42:11 +0200 (Fri, 30 Oct 2009) | 7 lines
Changed paths:
M /branches/zip/mysql-test/innodb-autoinc.result
branches/zip: This test has been problematic for sometime now. The underlying
bug is that the data dictionaries get out of sync. In the AUTOINC code we
try and apply salve to the symptoms. In the past MySQL made some unrelated
change and the dictionaries stopped getting out of sync and this test started
to fail. Now, it seems they have reverted that changed and the test is
passing again. I suspect this is not he last time that this test will change.
------------------------------------------------------------------------
Detailed revision comments:
r6123 | jyang | 2009-10-30 05:43:06 +0200 (Fri, 30 Oct 2009) | 8 lines
branches/5.1: In os_mem_alloc_large(), if we fail to attach
the shared memory, reset memory pointer ptr to NULL, and
allocate memory from conventional pool. This is a port
from branches/zip.
Bug #48237 Error handling in os_mem_alloc_large appears to be incorrect
rb://198 Approved by: Marko
Detailed revision comments:
r6052 | sunny | 2009-10-12 07:09:56 +0300 (Mon, 12 Oct 2009) | 4 lines
branches/5.1: Reset the statement level autoinc counter on ROLLBACK. Fix
the test results too.
rb://164
r6053 | sunny | 2009-10-12 07:37:49 +0300 (Mon, 12 Oct 2009) | 6 lines
branches/5.1: Copy the maximum AUTOINC value from the old table to the new
table when MySQL does a CREATE INDEX ON T. This is required because MySQL
does a table copy, rename and drops the old table.
Fix Bug#47125: auto_increment start value is ignored if an index is created and engine=innodb
rb://168
Detailed revision comments:
r6051 | sunny | 2009-10-12 07:05:00 +0300 (Mon, 12 Oct 2009) | 6 lines
branches/5.1: Ignore negative values supplied by the user when calculating the
next value to store in dict_table_t. Setting autoincrement columns top negative
values is undefined behavior and this change should bring the behavior of
InnoDB closer to what users expect. Added several tests to check.
rb://162
Detailed revision comments:
r6045 | jyang | 2009-10-08 02:27:08 +0300 (Thu, 08 Oct 2009) | 7 lines
branches/5.1: Fix bug #47777. Treat the Geometry data same as
Binary BLOB in ha_innobase::store_key_val_for_row(), since the
Geometry data is stored as Binary BLOB in Innodb.
Review: rb://180 approved by Marko Makela.
Detailed revision comments:
r5952 | calvin | 2009-09-22 19:45:07 +0300 (Tue, 22 Sep 2009) | 7 lines
branches/5.1: fix bug#42383: Can't create table 'test.bug39438'
For embedded server, MySQL may pass in full path, which is
currently disallowed. It is needed to relax the condition by
accepting full paths in the embedded case.
Approved by: Heikki (on IM)
When a query was using a DATE or DATETIME value formatted
using any other separator characters beside hyphen '-', a
query with a greater-or-equal '>=' condition matching only
the greatest value in an indexed column, the result was
empty if index range scan was employed.
The range optimizer got a new feature between 5.1.38 and
5.1.39 that changes a greater-or-equal condition to a
greater-than if the value matching that in the query was not
present in the table. But the value comparison function
compared the dates as strings instead of dates.
The bug was fixed by splitting the function
get_date_from_str in two: One part that parses and does
error checking. This function is now visible outside the
module. The old get_date_from_str now calls the new
function.
mysql-test/r/range.result:
Bug#47925: Test result
mysql-test/t/range.test:
Bug#47925: Test case
sql/item.cc:
Bug#47925: Fix + some edit on the comments
sql/item.h:
Bug#47925: Changed function signature
sql/item_cmpfunc.cc:
Bug#47925: Split function in two
sql/item_cmpfunc.h:
Bug#47925: Declaration of new function
sql/opt_range.cc:
Bug#47925: Added THD to function call
sql/time.cc:
Bug#47925: Added microsecond comparison
When starting the (5.1+) mysql command-line client, we try to get
"select @@version_comment" from the server to present it to the
user. Recent clients are aware that older servers do not have that
variable and fall back on other info to be able to present *something*
at least. This fallback string was allocated through the POSIX interface,
but released through the my*() suite, which rightfully complained about
the imbalance in calls when compiled with --debug. While this wasn't
as bad as it looked (no double-free, use of uninitialized or freed
buffer, etc.), it did look funky.
Using my_strdup() now for what will be my_free()d later.
client/mysql.cc:
Use my_strdup() for server_version, as we'll my_free() it later
and don't want to upset the mysql client's memory accounting.
Term::ReadKey"
Add the missing module import. Also, while here, fix a few glaring problems
with the script, and ensure that it behaves properly. It seems this script
may have never been working correctly (e.g., reading password didn't chomp()
the result, so password was set with \n at the end; comparing the re-typed
password to original was done with inverted test).
Add END { cleanup(); } block to ensure the script removes temporary working
files.
Add SIG{INT} / SIG{QUIT} handler.
Do a bit of reorganization to make the code easier to understand.
Limit failed connection attempts to 3.
Use ./bin/mysql if it exists, and then fall back on mysql in PATH (before it
assumed 'mysql' in the path). Print a nicer error if 'mysql' can't be called.
This has been tested on Windows (ActivePerl from cmd.exe, no cygwin needed)
and Linux.
with temporary tables
There were two problems the test case from this bug was
triggering:
1. JOIN::rollup_init() was supposed to wrap all constant Items
into another object for queries with the WITH ROLLUP modifier
to ensure they are never considered as constants and therefore
are written into temporary tables if the optimizer chooses to
employ them for DISTINCT/GROUP BY handling.
However, JOIN::rollup_init() was called before
make_join_statistics(), so Items corresponding to fields in
const tables could not be handled as intended, which was
causing all kinds of problems later in the query execution. In
particular, create_tmp_table() assumed all constant items
except "hidden" ones to be removed earlier by remove_const()
which led to improperly initialized Field objects for the
temporary table being created. This is what was causing crashes
and valgrind errors in storage engines.
2. Even when the above problem had been fixed, the query from
the test case produced incorrect results due to some
DISTINCT/GROUP BY optimizations being performed by the
optimizer that are inapplicable in the WITH ROLLUP case.
Fixed by disabling inapplicable DISTINCT/GROUP BY optimizations
when the WITH ROLLUP modifier is present, and splitting the
const-wrapping part of JOIN::rollup_init() into a separate
method which is now invoked after make_join_statistics() when
the const tables are already known.
mysql-test/r/olap.result:
Added a test case for bug #48131.
mysql-test/t/olap.test:
Added a test case for bug #48131.
sql/sql_select.cc:
1. Disabled inapplicable DISTINCT/GROUP BY optimizations when
the WITH ROLLUP modifier is present.
2. Split the const-wrapping part of JOIN::rollup_init() into a
separate method.
sql/sql_select.h:
Added rollup_process_const_fields() declaration.
subquery returning multiple rows
Error handling was missing when handling subqueires in WHERE
and when assigning a SELECT result to a @variable.
This caused crash(es).
Fixed by adding error handling code to both the WHERE
condition evaluation and to assignment to an @variable.
having clause...
The fix for bug 46184 was not very complete. It was not covering
views using temporary tables and multiple tables in a FROM clause.
Fixed by reverting the fix for 46184 and making a more general
check that is checking at the right execution stage and for all
of the non-supported cases.
Now PROCEDURE ANALYZE on non-top level SELECT is also forbidden.
Updated the analyse.test and subselect.test accordingly.
CURRENT_USER() in GRANT ... TO CURRENT_USER() only gave us a definer,
not a full user (i.e., password-element was not initiliazed). Hence
dereferencing the password led to a crash.
Properly initializes definers now, just so there are no misunderstandings.
Also does some magic so IDENTIFIED BY ... works with CURRENT_USER().
mysql-test/r/grant2.result:
Show GRANT ... TO CURRENT_USER() no longer crashes.
Show it to work with IDENTIFIED BY to boot.
mysql-test/t/grant2.test:
Show GRANT ... TO CURRENT_USER() no longer crashes.
Show it to work with IDENTIFIED BY to boot.
sql/sql_acl.cc:
Make IDENTIFIED BY ... work with CURRENT_USER()
sql/sql_parse.cc:
Zero password-part of definer just in case somebody mistakes this for
a complete LEX_USER!
If an outer query is broken, a subquery might not even get set up.
EXPLAIN EXTENDED did not expect this and merrily tried to de-ref all
of the half-setup info.
We now catch this case and print as much as we have, as it doesn't cost us
anything (doesn't make regular execution slower).
mysql-test/r/explain.result:
Show that EXPLAIN EXTENDED with subquery and illegal out query doesn't crash.
Show also that SHOW WARNINGS will render an additional Note in the hope of
being, well, helpful.
mysql-test/t/explain.test:
If we have only half a query for EXPLAIN EXTENDED to print (i.e.,
incomplete subquery info as outer query is illegal), we should
provide the user with as much info as we easily can if they ask
for it. What we should not do is crash when they come asking for
help, that violates etiquette in some countries.
sql/item_subselect.cc:
If the sub-query's actually set up, print it. Otherwise, elide.
Queries with nested outer joins may lead to crashes or
bad results because an internal data structure is not handled
correctly.
The optimizer uses bitmaps of nested JOINs to determine
if certain table can be placed at a certain place in the
JOIN order.
It does maintain a bitmap describing in which JOINs
last placed table is nested.
When it puts a table it makes sure the bit of every JOIN that
contains the table in question is set (because JOINs can be nested).
It does that by recursively setting the bit for the next enclosing
JOIN when this is the first table in the JOIN and recursively
resetting the bit if it's the last table in the JOIN.
When it removes a table from the join order it should do the
opposite : recursively unset the bit if it's the only remaining
table in this join and and recursively set the bit if it's removing
the last table of a JOIN.
There was an error in how the bits was set for the upper levels :
when removing a table it was setting the bit for all the enclosing
nested JOINs even if there were more tables left in the current JOIN
(which practically means that the upper nested JOINs were not affected).
Fixed by stopping the recursion at the relevant level.
mysql-test/r/join.result:
Bug #42116: test case
mysql-test/t/join.test:
Bug #42116: test case
sql/sql_select.cc:
Bug #41116: don't go up and set the bits if more tables in
at the current JOIN level
The 'rpl_get_master_version_and_clock' test verifies if the slave I/O
thread tries to reconnect to master when it tries to get the values of
the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection.
So the master server is restarted for making the transient network
disconnection. Restarting master server can bring two problems as following:
1. The time out error is encountered sporadically. The slave I/O thread tries
to reconnect master ten times, which is set in my.cnf. So in the test
framework sporadically the slave I/O thread really stoped when it can't
reconnect to master in the ten times successfully before the master starts,
then the time out error will be encountered while waiting for the slave to
start.
2. These warnings and errors are produced in server log file when
the slave I/O thread tries to get the values of the UNIX_TIMESTAMP,
SERVER_ID from master under the transient network disconnection.
To fix problem 1, increase the master retry count to sixty times,
so that the slave I/O thread has enough time to reconnect master
successfully.
To fix problem 2, suppress these warnings and errors by mtr suppression,
because they are expected.
mysql-test/suite/rpl/t/rpl_get_master_version_and_clock-slave.opt:
Added the *.opt file for increasing master retry count to
sixty times.
mysql-test/suite/rpl/t/rpl_get_master_version_and_clock.test:
Added mtr suppression for suppressing warnings and errors
in server log file.
XA START may cause assertion failure/server crash when it is called
after unilateral roll back issued by the Resource Manager (both
in regular transaction and after XA transaction).
The problem was that rm_error variable wasn't set/reset properly.
mysql-test/r/xa.result:
A test case for BUG#43171.
mysql-test/t/xa.test:
A test case for BUG#43171.
sql/handler.cc:
Setting rm_error when we're out of XA transaction has no
special meaning. But it blocks reset of thd->transaction.xid
structure later.
sql/sql_parse.cc:
Reset rm_error before we enter ha_rollback(), so
thd->transaction.xid strucure is reinitialized.
Bug#46539 Various crashes on INSERT IGNORE SELECT + SELECT FOR UPDATE.
If a transaction was rolled back inside InnoDB due to a deadlock
or lock wait timeout, and the statement had IGNORE clause,
the server could crash at the end of the statement or on shutdown.
This was caused by the error handling infrastructure's attempt to
ignore a non-ignorable error.
When a transaction rollback request is raised, switch off
current_select->no_error flag, so that the following error
won't be ignored.
Instead, we could add !thd->is_fatal_sub_stmt_error to
my_message_sql(), but since in write_record() we switch
off no_error, the same approach is used in
thd_mark_transaction_to_rollback().
@todo: call thd_mark_transaction_to_rollback() from
handler::print_error(), then we can easily make sure
that the error reported by print_error is not ignored.
mysql-test/r/innodb_lock_wait_timeout_1.result:
Update results (Bug#46539).
mysql-test/t/innodb_lock_wait_timeout_1.test:
Add a test case for Bug#46539
sql/sql_class.cc:
When a transaction rollback request is raised, switch of
current_select->no_error flag, so that the following error
won't be ignored.