The bug 38816 changed the lock that protects THD::query from
LOCK_thread_count to LOCK_thd_data, but didn't update the associated
InnoDB functions.
1. The innobase_mysql_prepare_print_arbitrary_thd and the
innobase_mysql_end_print_arbitrary_thd InnoDB functions have been
removed, since now we have a per-thread mutex: now we don't need to wrap
several inter-thread access tries to THD::query with a single global
LOCK_thread_count lock, so we can simplify the code.
2. The innobase_mysql_print_thd function has been modified to lock
LOCK_thd_data in direct way.
SET TRANSACTION ISOLATION LEVEL is used to temporarily set
the trans.iso.level for the next transaction. After the
transaction, the iso.level is (re-)set to value of the
session variable 'tx_isolation'.
The bug is caused by setting the thd->variables.tx_isolation
field to the value of the session variable upon each
statement commit. It should only be set at the end of the
full transaction.
The fix has been to remove the setting of the variable in
ha_autocommit_or_rollback if we're in a transaction, as it
will be correctly set in either ha_rollback or
ha_commit_one_phase.
If, on the other hand, we're in autocommit mode, tx_isolation
will be explicitly set here.
The 'slave_patternload_file' is assigned to the real path of the load data file
when initializing the object of Relay_log_info. But the path of the load data
file is not formatted to real path when executing event from relay log. So the
error will be encountered if the path of the load data file is a symbolic link.
Actually the global 'opt_secure_file_priv' is not formatted to real path when
loading data from file. So the same thing will happen too.
To fix these errors, the path of the load data file should be formatted to
real path when executing event from relay log. And the 'opt_secure_file_priv'
should be formatted to real path when loading data infile.
<tmp_tbl> with RBL
When binlogging the statement, the server always handle the existing
object as a table, even though it is a view. However a view is
handled differently in other parts of the code thus leading the
statement to crash in RBL if the view exists.
This happens because the underlying tables for the view are not opened
when we try to call store_create_info() on the view in order to build
a CREATE TABLE statement.
This patch will only address the crash problem, other binlogging
problems related to CREATE TABLE IF NOT EXISTS LIKE when the existing
object is a view will be solved by BUG 47442.
for each record'
There was an error in an internal structure in the range
optimizer (SEL_ARG). Bad design causes parts of a data
structure not to be initialized when it is in a certain
state. All client code must check that this state is not
present before trying to access the structure's data. Fixed
by
- Checking the state before trying to access data (in
several places, most of which not covered by test case.)
- Copying the keypart id when cloning SEL_ARGs
BUG#46000 - using index called GEN_CLUST_INDEX crashes server
Detailed revision comments:
r6180 | jyang | 2009-11-17 10:54:57 +0200 (Tue, 17 Nov 2009) | 7 lines
branches/5.0: Merge/Port fix for bug #46000 from branches/5.1
-r5895 to branches/5.0. Disallow creating index with the
name of "GEN_CLUST_INDEX" which is reserved for the default
system primary index. Minor adjusts on table name screening
format for added tests.
BUG#47777 - innodb dies with spatial pk: Failing assertion: buf <= original_buf + buf_len
Detailed revision comments:
r6178 | jyang | 2009-11-17 08:52:11 +0200 (Tue, 17 Nov 2009) | 6 lines
branches/5.0: Merge fix for bug #47777 from branches/5.1 -r6045
to bracnches/5.0. Treat the Geometry data same as Binary BLOB
in ha_innobase::store_key_val_for_row(), since the Geometry
data is stored as Binary BLOB in Innodb.
In RBR, All statements operating on temporary tables should not be binlogged.
Despite this fact, after executing 'TRUNCATE... ' on a temporary table,
the command is still logged, even if in row-based mode. Consequently, this raises
problems in the slave as the table may not exist, resulting in an
execution failure. Ultimately, this causes the slave to report
an error and abort.
After this patch, 'TRUNCATE ...' statement on a temporary table will not be
binlogged in RBR.
The problem is that the server could crash when attempting
to access a non-conformant proc system table. One such case
was a crash when invoking stored procedure related statements
on a 5.1 server with a proc system table in the 5.0 format.
The solution is to validate the proc system table format
before attempts to access it are made. If the table is not
in the format that the server expects, a message is written
to the error log and the statement that caused the table to
be accessed fails.
This patch introduce a limit on the time the query cache can
block with a lock on SELECTs.
Other operations which causes a change in the table
data will still be blocked.
Bug #48370 Absolutely wrong calculations with GROUP BY and
decimal fields when using IF
Added the test cases in the above two bugs for regression
testing.
Added additional tests that demonstrate a incomplete fix.
Added a new factory method for Field_new_decimal to
create a field from an (decimal returning) Item.
In the new method made sure that all the precision and
length variables are capped in a proper way.
This is required because Item's can have larger precision
than the decimal fields and thus need to be capped when
creating a field based on an Item type.
Fixed the wrong typecast to Item_decimal.
When merging ranges during calculation of the result of OR
to two range sets the current range may be obsoleted by the
resulting merged range.
The first overlapping range can be obsoleted as well.
Fixed by moving the pointer to the first overlapping range to the
pointer of the resulting union range.
Added few comments at key places in key_or().
Problem: Some system functions that could return different values on
master and slave were not marked unsafe. In particular:
GET_LOCK
IS_FREE_LOCK
IS_USED_LOCK
MASTER_POS_WAIT
RELEASE_LOCK
SLEEP
SYSDATE
VERSION
Fix: Mark these functions unsafe.
DELETE IGNORE
The ER_CANT_UPDATE_USED_TABLE_IN_SF_OR_TRG error was set in the
diagnostics area when it happened, but the DELETE cleanup code
never checked for a non-fatal error condition, thus trying to
set diag.area to "ok". This triggered an assert checking that
the diag.area was empty.
The fix was to test if there existed a non-fatal error condition
(thd->is_error() before ok'ing the operation.
The problem was a "self-deadlock" if the connection issuing INSERT DELAYED
had both the global read lock (FLUSH TABLES WITH READ LOCK) and LOCK TABLES
mode active. The table being inserted into had to be different from the
table(s) locked by LOCK TABLES.
For INSERT DELAYED, the connection thread waits until the handler thread has
opened and locked its table before returning. But since the global read lock
was active, the handler thread would be unable to lock and would wait for the
global read lock to go away.
So the handler thread would be waiting for the connection thread to release
the global read lock while the connection thread was waiting for the handler
thread to lock the table. This gave a "self-deadlock" (same connection,
different threads).
The deadlock would only happen if we also had LOCK TABLES mode since the
INSERT otherwise will try to get protection against global read lock before
starting the handler thread. It will then notice that the global read lock
is owned by the same connection and report ER_CANT_UPDATE_WITH_READLOCK.
This patch removes the deadlock by reporting ER_CANT_UPDATE_WITH_READLOCK
also if we are inside LOCK TABLES mode.
Test case added to delayed.test.
WHERE conditions
check_group_min_max() checks if the loose index scan
optimization is applicable for a given WHERE condition, that is
if the MIN/MAX attribute participates only in range predicates
comparing the corresponding field with constants.
The problem was that it considered the whole predicate suitable
for the loose index scan optimization as soon as it encountered
a constant as a predicate argument. This is obviously wrong for
cases when a constant is the first argument of a predicate
which does not satisfy the above condition.
Fixed check_group_min_max() so that all arguments of the input
predicate are considered to decide if it passes the test, even
though a constant has already been encountered.
MySQL manual describes values of the YEAR(2) field type as follows:
values 00 - 69 mean 2000 - 2069 years and values 70 - 99 mean 1970 - 1999
years. MIN/MAX and comparison functions was comparing them as int values
thus producing wrong result.
Now the Arg_comparator class is extended with compare_year function which
performs correct comparison of the YEAR type.
The Item_sum_hybrid class now uses Item_cache and Arg_comparator objects to
correctly calculate its value.
To allow Arg_comparator to use func_name() function for Item_func and Item_sum
objects the func_name declaration is moved to the Item_result_field class.
A helper function is_owner_equal_func is added to the Arg_comparator class.
It checks whether the Arg_comparator object owner is the <=> function or not.
A helper function setup is added to the Item_sum_hybrid class. It sets up
cache item and comparator.
init_read_record() - (records.cc:274)
Item_cond::used_tables_cache was accessed in
records.cc#init_read_record() without being initialized. It had
not been initialized because it was wrongly assumed that the
Item's variables would not be accessed, and hence
quick_fix_field() was used instead of fix_fields() to save a few
CPU cycles at creation time.
The fix is to properly initilize the Item by replacing
quick_fix_field() with fix_fields().
This patch borrows ideas, text and code from Kristofer
Pettersson's patch.
An assignment of a system variable sharing the same base
name as a declared stored procedure variable in the same
context could lead to a crash.
The reason was that during the parsing of the syntactic
rule 'option_value' an uninitialized set_var object was
pushed to the parameter stack of the SET statement. The
parent rule 'option_type_value' interpreted the existence
of variables on the parameter stack as an assignment and
wrapped it in a sp_instr_set object.
As the procedure later was executed an attempt was made
to run the method 'check()' on an uninitialized member
object (NULL value) belonging to the previously created
but uninitialized object.
This patch refactors the 'internal_variable_name' rule and
copies the semantic analysis part to the depending parent
rule: 'option_value'. This makes it possible to account
for any prefixes affecting the interpretation of the
internal_variable_name.