The problem was a "self-deadlock" if the connection issuing INSERT DELAYED
had both the global read lock (FLUSH TABLES WITH READ LOCK) and LOCK TABLES
mode active. The table being inserted into had to be different from the
table(s) locked by LOCK TABLES.
For INSERT DELAYED, the connection thread waits until the handler thread has
opened and locked its table before returning. But since the global read lock
was active, the handler thread would be unable to lock and would wait for the
global read lock to go away.
So the handler thread would be waiting for the connection thread to release
the global read lock while the connection thread was waiting for the handler
thread to lock the table. This gave a "self-deadlock" (same connection,
different threads).
The deadlock would only happen if we also had LOCK TABLES mode since the
INSERT otherwise will try to get protection against global read lock before
starting the handler thread. It will then notice that the global read lock
is owned by the same connection and report ER_CANT_UPDATE_WITH_READLOCK.
This patch removes the deadlock by reporting ER_CANT_UPDATE_WITH_READLOCK
also if we are inside LOCK TABLES mode.
Test case added to delayed.test.
WHERE conditions
check_group_min_max() checks if the loose index scan
optimization is applicable for a given WHERE condition, that is
if the MIN/MAX attribute participates only in range predicates
comparing the corresponding field with constants.
The problem was that it considered the whole predicate suitable
for the loose index scan optimization as soon as it encountered
a constant as a predicate argument. This is obviously wrong for
cases when a constant is the first argument of a predicate
which does not satisfy the above condition.
Fixed check_group_min_max() so that all arguments of the input
predicate are considered to decide if it passes the test, even
though a constant has already been encountered.
MySQL manual describes values of the YEAR(2) field type as follows:
values 00 - 69 mean 2000 - 2069 years and values 70 - 99 mean 1970 - 1999
years. MIN/MAX and comparison functions was comparing them as int values
thus producing wrong result.
Now the Arg_comparator class is extended with compare_year function which
performs correct comparison of the YEAR type.
The Item_sum_hybrid class now uses Item_cache and Arg_comparator objects to
correctly calculate its value.
To allow Arg_comparator to use func_name() function for Item_func and Item_sum
objects the func_name declaration is moved to the Item_result_field class.
A helper function is_owner_equal_func is added to the Arg_comparator class.
It checks whether the Arg_comparator object owner is the <=> function or not.
A helper function setup is added to the Item_sum_hybrid class. It sets up
cache item and comparator.
init_read_record() - (records.cc:274)
Item_cond::used_tables_cache was accessed in
records.cc#init_read_record() without being initialized. It had
not been initialized because it was wrongly assumed that the
Item's variables would not be accessed, and hence
quick_fix_field() was used instead of fix_fields() to save a few
CPU cycles at creation time.
The fix is to properly initilize the Item by replacing
quick_fix_field() with fix_fields().
This patch borrows ideas, text and code from Kristofer
Pettersson's patch.
An assignment of a system variable sharing the same base
name as a declared stored procedure variable in the same
context could lead to a crash.
The reason was that during the parsing of the syntactic
rule 'option_value' an uninitialized set_var object was
pushed to the parameter stack of the SET statement. The
parent rule 'option_type_value' interpreted the existence
of variables on the parameter stack as an assignment and
wrapped it in a sp_instr_set object.
As the procedure later was executed an attempt was made
to run the method 'check()' on an uninitialized member
object (NULL value) belonging to the previously created
but uninitialized object.
This patch refactors the 'internal_variable_name' rule and
copies the semantic analysis part to the depending parent
rule: 'option_value'. This makes it possible to account
for any prefixes affecting the interpretation of the
internal_variable_name.
Until-pos guarding did not distiguish the master originated events from ones that the slave
can introduce to the relay log e.g Rotate to the next relay log at slave restarting.
The local Rotate's coordinate are incomparable with the Until-master-pos.
That led to the unexpectable stop this bug describes.
Fixed with to avoid Until-master-pos comparison for a local slave's event.
Notice that if --replicate-same-server is true such event is treated as coming from
the master side.
deadlock was encountered
The bug is caused by an inconsistent handling of the IGNORE
clause. A read from a const table caused a lock timeout
(ER_LOCK_TIMEOUT) in innodb. Since the IGNORE clause was
given, the timeout was converted into a warning instead of
an error, thus not populating the diagnostics area. When
innodb subsequently marked the transaction for rollback,
mysql asserted since the diag.area was empty.
This patch consists of only a test case, as the bug itself
was fixed by the patch for Bug #46539
on any access
Archive engine for 5.1 (and latter) version uses a modified
version of zlib (azlib). These two version are incompatible
so a proper upgrade is needed before tables created in 5.0
can be used reliable.
This upgrade can be performed using repair. But due to lack
of test its risky to allow upgrade for now. This patch addresses
only the crashing issue. Any attempt to repair will be blocked.
Eventually repair can be allowed to run through (which will also
cause an upgrade from older version to newer) but only after a
thorough testing.
memory
The server was doing a bad class typecast causing setting of
wrong value for the maximum number of items in an internal
structure used in equality propagation.
Fixed by not doing the wrong typecast and asserting the type
of the Item where it should be done.
values
We should re-set the access method functions when changing the access
method when switching to another index to avoid sorting.
Fixed by doing a little re-engineering : encapsulating all the function
assignment into a special function and calling it when flipping the
indexes.
only const tables
The problem was caused by two shortcuts in the optimizer that
are inapplicable in the ROLLUP case.
Normally in a case when only const tables are involved in a
query, DISTINCT clause can be safely optimized away since there
may be only one row produced by the join. Similarly, we don't
need to create a temporary table to resolve DISTINCT/GROUP
BY/ORDER BY. Both of these are inapplicable when the WITH
ROLLUP modifier is present.
Fixed by disabling the said optimizations for the WITH ROLLUP
case.
The SE API requires mysql to notify the storage engine that
it's going to read certain tables at the beginning of the
statement (by calling start_stmt(), store_lock() or
external_lock()).
These are typically called by the lock_tables().
However SHOW CREATE TABLE is not pre-locking the tables
because it's not expected to access the data at all.
But for some view definitions (that include comparing a
date/datetime/timestamp column to a string returning
scalar subquery) the JOIN::prepare may still access data
when materializing the scalar non-correlated subquery
in Arg_comparator::can_compare_as_dates().
Fixed by not materializing the subquery when the function
is called in a SHOW/EXPLAIN/CREATE VIEW
BUG#47983: rpl_extraColmaster_myisam failed in PB2 with "Found
warnings!!"
BUG 45214 fixed the case when get_master_version_and_clock
function, used by the slave, would not report errors. The slave
now detects them and if related to transient network failures, it
prints some warnings and retries to connect. On the other hand,
if not network related, it just gives up and fails.
As such, sometimes, in PB2, the slave comes across some transient
communication issues between master and slave, while calling
get_master_version_and_clock, causing warnings print outs to the
error log. Nevertheless, in such cases slave retries to connect,
in which it succeeds, and the test case continues as it normally
would. But then, at the end of a successful test run, MTR checks
the error log, finds the unexpected warnings and considers them
harmful. This causes MTR to report error and, consequently, PB2
to report a failing test.
We fix this by adding to the global warnings suppress list the
warnings related to transient network failures only, which are
reported while in function get_master_version_and_clock.
Bug#41756 "Strange error messages about locks from InnoDB".
In JT_EQ_REF (join_read_key()) access method,
don't try to unlock rows in the handler, unless certain that
a) they were locked
b) they are not used.
Unlocking of rows is done by the logic of the nested join loop,
and is unaware of the possible caching that the access method may
have. This could lead to double unlocking, when a row
was unlocked first after reading into the cache, and then
when taken from cache, as well as to unlocking of rows which
were actually used (but taken from cache).
Delegate part of the unlocking logic to the access method,
and in JT_EQ_REF count how many times a record was actually
used in the join. Unlock it only if it's usage count is 0.
Implemented review comments.
Bug#41756 "Strange error messages about locks from InnoDB".
In JT_EQ_REF (join_read_key()) access method,
don't try to unlock rows in the handler, unless certain that
a) they were locked
b) they are not used.
Unlocking of rows is done by the logic of the nested join loop,
and is unaware of the possible caching that the access method may
have. This could lead to double unlocking, when a row
was unlocked first after reading into the cache, and then
when taken from cache, as well as to unlocking of rows which
were actually used (but taken from cache).
Delegate part of the unlocking logic to the access method,
and in JT_EQ_REF count how many times a record was actually
used in the join. Unlock it only if it's usage count is 0.
Implemented review comments.
values return too many records
WHERE clauses with "outer_value_list NOT IN subselect" were
handled incorrectly if the outer value list contained multiple
items where at least one of these could be NULL. The first
outer record with NULL value was handled correctly, but if a
second record with NULL value existed, the optimizer would
choose to reuse the result it got on the last execution of the
subselect. This is incorrect if the outer value list has
multiple items.
The fix is to make Item_in_optimizer::val_int (in
item_cmpfunc.cc) reuse the result of the latest execution
for NULL values only if all values in the outer_value_list
are NULL.
Detailed revision comments:
r6101 | jyang | 2009-10-23 11:45:50 +0300 (Fri, 23 Oct 2009) | 7 lines
branches/zip: Update test result with the WARN_LEVEL_ERROR
to WARN_LEVEL_WARN change. This is the same result as
submitted in rb://172 review, which approved by Sunny Bains
and Marko.
Detailed revision comments:
r6100 | jyang | 2009-10-22 06:51:07 +0300 (Thu, 22 Oct 2009) | 6 lines
branches/zip: As a request from mysql, WARN_LEVEL_ERROR cannot
be used for push_warning_* call any more. Switch to
WARN_LEVEL_WARN. Bug #47233.
rb://172 approved by Sunny Bains and Marko.
Detailed revision comments:
r6095 | vasil | 2009-10-19 16:04:59 +0300 (Mon, 19 Oct 2009) | 7 lines
branches/zip:
Fix Bug#47808 innodb_information_schema.test fails when run under valgrind
by using the wait_until_rows_count macro that loops until the number of
rows becomes 14 instead of sleep 0.1, which is obviously very fragile.
When a sessione is closed, all temporary tables of the session are automatically
dropped and are binlogged. But it will be binlogged with wrong database names when
the length of the temporary tables' database names are greater than the
length of the current database name or the current database is not set.
Query_log_event's db_len is forgot to set when Query_log_event's db is set.
This patch wrote code to set db_len immediately after db has set.
- disabled main.innodb_bug47777.test with InnoDB plugin
until fix for plugin is applied.
- disabled main.innodb-autoinc.test (failing)
- re-enabled main.innodb_bug39438.test
- added error message suppression to innodb_bug39438, as
requested by InnoDB/Oracle
- reverted change to main.innodb_bug34300 as plugin specific.
ONLY_FULL_GROUP_BY
Problem was that during checking and preparation of the
partitioining function as a side effect in fix_fields
the full_group_by_flag was changed.
Solution was to set it back to its original value after
calling fix_fields.
Updated patch, to also exclude allow_sum_func from being
affected of fix_fields, as requested by reviewer.
Detailed revision comments:
r6127 | vasil | 2009-10-30 11:18:25 +0200 (Fri, 30 Oct 2009) | 18 lines
branches/5.1:
Backport c6121 from branches/zip:
------------------------------------------------------------------------
r6121 | sunny | 2009-10-30 01:42:11 +0200 (Fri, 30 Oct 2009) | 7 lines
Changed paths:
M /branches/zip/mysql-test/innodb-autoinc.result
branches/zip: This test has been problematic for sometime now. The underlying
bug is that the data dictionaries get out of sync. In the AUTOINC code we
try and apply salve to the symptoms. In the past MySQL made some unrelated
change and the dictionaries stopped getting out of sync and this test started
to fail. Now, it seems they have reverted that changed and the test is
passing again. I suspect this is not he last time that this test will change.
------------------------------------------------------------------------
Detailed revision comments:
r6052 | sunny | 2009-10-12 07:09:56 +0300 (Mon, 12 Oct 2009) | 4 lines
branches/5.1: Reset the statement level autoinc counter on ROLLBACK. Fix
the test results too.
rb://164
r6053 | sunny | 2009-10-12 07:37:49 +0300 (Mon, 12 Oct 2009) | 6 lines
branches/5.1: Copy the maximum AUTOINC value from the old table to the new
table when MySQL does a CREATE INDEX ON T. This is required because MySQL
does a table copy, rename and drops the old table.
Fix Bug#47125: auto_increment start value is ignored if an index is created and engine=innodb
rb://168
Detailed revision comments:
r6051 | sunny | 2009-10-12 07:05:00 +0300 (Mon, 12 Oct 2009) | 6 lines
branches/5.1: Ignore negative values supplied by the user when calculating the
next value to store in dict_table_t. Setting autoincrement columns top negative
values is undefined behavior and this change should bring the behavior of
InnoDB closer to what users expect. Added several tests to check.
rb://162
Detailed revision comments:
r6045 | jyang | 2009-10-08 02:27:08 +0300 (Thu, 08 Oct 2009) | 7 lines
branches/5.1: Fix bug #47777. Treat the Geometry data same as
Binary BLOB in ha_innobase::store_key_val_for_row(), since the
Geometry data is stored as Binary BLOB in Innodb.
Review: rb://180 approved by Marko Makela.
When a query was using a DATE or DATETIME value formatted
using any other separator characters beside hyphen '-', a
query with a greater-or-equal '>=' condition matching only
the greatest value in an indexed column, the result was
empty if index range scan was employed.
The range optimizer got a new feature between 5.1.38 and
5.1.39 that changes a greater-or-equal condition to a
greater-than if the value matching that in the query was not
present in the table. But the value comparison function
compared the dates as strings instead of dates.
The bug was fixed by splitting the function
get_date_from_str in two: One part that parses and does
error checking. This function is now visible outside the
module. The old get_date_from_str now calls the new
function.
The reason for the bug is that mysqtest as well as other client tools
running in test suite (mysqlbinlog, mysqldump) will first try to connect
whatever database has created shared memory with default base name
"MySQL" and use this. (Same effect could be seen on Unix if mtr would
not care to calculate "port" and "socket" parameter).
The fix ensures that all client tools and running in mtr use unique
per-database shared memory base parameters, so there is no possibility
to clash with already installed one. We use socket name for shared memory
base (it's known to be unique). This shared-memory-base is written to the
MTR config file to the [client] and [mysqld] sections. Fix made also made
sure all client tools understand and correctly handle --shared-memory-base.
Prior to this patch it was not the case for mysqltest, mysqlbinlog and
mysql_client_test.
All new connections done from mtr scripts via connect() will by default
set shared-memory-base. And finally, there is a possibility to force
shared memory or pipe connection and overwrite shared memory/pipe base name
from within mtr scripts via optional PIPE or SHM modifier. This functionality
was manually backported from 6.0
(original patch http://lists.mysql.com/commits/74749)