Bug#41756 "Strange error messages about locks from InnoDB".
In JT_EQ_REF (join_read_key()) access method,
don't try to unlock rows in the handler, unless certain that
a) they were locked
b) they are not used.
Unlocking of rows is done by the logic of the nested join loop,
and is unaware of the possible caching that the access method may
have. This could lead to double unlocking, when a row
was unlocked first after reading into the cache, and then
when taken from cache, as well as to unlocking of rows which
were actually used (but taken from cache).
Delegate part of the unlocking logic to the access method,
and in JT_EQ_REF count how many times a record was actually
used in the join. Unlock it only if it's usage count is 0.
Implemented review comments.
Bug#41756 "Strange error messages about locks from InnoDB".
In JT_EQ_REF (join_read_key()) access method,
don't try to unlock rows in the handler, unless certain that
a) they were locked
b) they are not used.
Unlocking of rows is done by the logic of the nested join loop,
and is unaware of the possible caching that the access method may
have. This could lead to double unlocking, when a row
was unlocked first after reading into the cache, and then
when taken from cache, as well as to unlocking of rows which
were actually used (but taken from cache).
Delegate part of the unlocking logic to the access method,
and in JT_EQ_REF count how many times a record was actually
used in the join. Unlock it only if it's usage count is 0.
Implemented review comments.
values return too many records
WHERE clauses with "outer_value_list NOT IN subselect" were
handled incorrectly if the outer value list contained multiple
items where at least one of these could be NULL. The first
outer record with NULL value was handled correctly, but if a
second record with NULL value existed, the optimizer would
choose to reuse the result it got on the last execution of the
subselect. This is incorrect if the outer value list has
multiple items.
The fix is to make Item_in_optimizer::val_int (in
item_cmpfunc.cc) reuse the result of the latest execution
for NULL values only if all values in the outer_value_list
are NULL.
Detailed revision comments:
r6101 | jyang | 2009-10-23 11:45:50 +0300 (Fri, 23 Oct 2009) | 7 lines
branches/zip: Update test result with the WARN_LEVEL_ERROR
to WARN_LEVEL_WARN change. This is the same result as
submitted in rb://172 review, which approved by Sunny Bains
and Marko.
Detailed revision comments:
r6100 | jyang | 2009-10-22 06:51:07 +0300 (Thu, 22 Oct 2009) | 6 lines
branches/zip: As a request from mysql, WARN_LEVEL_ERROR cannot
be used for push_warning_* call any more. Switch to
WARN_LEVEL_WARN. Bug #47233.
rb://172 approved by Sunny Bains and Marko.
Detailed revision comments:
r6095 | vasil | 2009-10-19 16:04:59 +0300 (Mon, 19 Oct 2009) | 7 lines
branches/zip:
Fix Bug#47808 innodb_information_schema.test fails when run under valgrind
by using the wait_until_rows_count macro that loops until the number of
rows becomes 14 instead of sleep 0.1, which is obviously very fragile.
When a sessione is closed, all temporary tables of the session are automatically
dropped and are binlogged. But it will be binlogged with wrong database names when
the length of the temporary tables' database names are greater than the
length of the current database name or the current database is not set.
Query_log_event's db_len is forgot to set when Query_log_event's db is set.
This patch wrote code to set db_len immediately after db has set.
- disabled main.innodb_bug47777.test with InnoDB plugin
until fix for plugin is applied.
- disabled main.innodb-autoinc.test (failing)
- re-enabled main.innodb_bug39438.test
- added error message suppression to innodb_bug39438, as
requested by InnoDB/Oracle
- reverted change to main.innodb_bug34300 as plugin specific.
The reason for the bug is that mysqtest as well as other client tools
running in test suite (mysqlbinlog, mysqldump) will first try to connect
whatever database has created shared memory with default base name
"MySQL" and use this. (Same effect could be seen on Unix if mtr would
not care to calculate "port" and "socket" parameter).
The fix ensures that all client tools and running in mtr use unique
per-database shared memory base parameters, so there is no possibility
to clash with already installed one. We use socket name for shared memory
base (it's known to be unique). This shared-memory-base is written to the
MTR config file to the [client] and [mysqld] sections. Fix made also made
sure all client tools understand and correctly handle --shared-memory-base.
Prior to this patch it was not the case for mysqltest, mysqlbinlog and
mysql_client_test.
All new connections done from mtr scripts via connect() will by default
set shared-memory-base. And finally, there is a possibility to force
shared memory or pipe connection and overwrite shared memory/pipe base name
from within mtr scripts via optional PIPE or SHM modifier. This functionality
was manually backported from 6.0
(original patch http://lists.mysql.com/commits/74749)
Detailed revision comments:
r6127 | vasil | 2009-10-30 11:18:25 +0200 (Fri, 30 Oct 2009) | 18 lines
branches/5.1:
Backport c6121 from branches/zip:
------------------------------------------------------------------------
r6121 | sunny | 2009-10-30 01:42:11 +0200 (Fri, 30 Oct 2009) | 7 lines
Changed paths:
M /branches/zip/mysql-test/innodb-autoinc.result
branches/zip: This test has been problematic for sometime now. The underlying
bug is that the data dictionaries get out of sync. In the AUTOINC code we
try and apply salve to the symptoms. In the past MySQL made some unrelated
change and the dictionaries stopped getting out of sync and this test started
to fail. Now, it seems they have reverted that changed and the test is
passing again. I suspect this is not he last time that this test will change.
------------------------------------------------------------------------
Detailed revision comments:
r6052 | sunny | 2009-10-12 07:09:56 +0300 (Mon, 12 Oct 2009) | 4 lines
branches/5.1: Reset the statement level autoinc counter on ROLLBACK. Fix
the test results too.
rb://164
r6053 | sunny | 2009-10-12 07:37:49 +0300 (Mon, 12 Oct 2009) | 6 lines
branches/5.1: Copy the maximum AUTOINC value from the old table to the new
table when MySQL does a CREATE INDEX ON T. This is required because MySQL
does a table copy, rename and drops the old table.
Fix Bug#47125: auto_increment start value is ignored if an index is created and engine=innodb
rb://168
Detailed revision comments:
r6051 | sunny | 2009-10-12 07:05:00 +0300 (Mon, 12 Oct 2009) | 6 lines
branches/5.1: Ignore negative values supplied by the user when calculating the
next value to store in dict_table_t. Setting autoincrement columns top negative
values is undefined behavior and this change should bring the behavior of
InnoDB closer to what users expect. Added several tests to check.
rb://162
Detailed revision comments:
r6045 | jyang | 2009-10-08 02:27:08 +0300 (Thu, 08 Oct 2009) | 7 lines
branches/5.1: Fix bug #47777. Treat the Geometry data same as
Binary BLOB in ha_innobase::store_key_val_for_row(), since the
Geometry data is stored as Binary BLOB in Innodb.
Review: rb://180 approved by Marko Makela.
When a query was using a DATE or DATETIME value formatted
using any other separator characters beside hyphen '-', a
query with a greater-or-equal '>=' condition matching only
the greatest value in an indexed column, the result was
empty if index range scan was employed.
The range optimizer got a new feature between 5.1.38 and
5.1.39 that changes a greater-or-equal condition to a
greater-than if the value matching that in the query was not
present in the table. But the value comparison function
compared the dates as strings instead of dates.
The bug was fixed by splitting the function
get_date_from_str in two: One part that parses and does
error checking. This function is now visible outside the
module. The old get_date_from_str now calls the new
function.
with temporary tables
There were two problems the test case from this bug was
triggering:
1. JOIN::rollup_init() was supposed to wrap all constant Items
into another object for queries with the WITH ROLLUP modifier
to ensure they are never considered as constants and therefore
are written into temporary tables if the optimizer chooses to
employ them for DISTINCT/GROUP BY handling.
However, JOIN::rollup_init() was called before
make_join_statistics(), so Items corresponding to fields in
const tables could not be handled as intended, which was
causing all kinds of problems later in the query execution. In
particular, create_tmp_table() assumed all constant items
except "hidden" ones to be removed earlier by remove_const()
which led to improperly initialized Field objects for the
temporary table being created. This is what was causing crashes
and valgrind errors in storage engines.
2. Even when the above problem had been fixed, the query from
the test case produced incorrect results due to some
DISTINCT/GROUP BY optimizations being performed by the
optimizer that are inapplicable in the WITH ROLLUP case.
Fixed by disabling inapplicable DISTINCT/GROUP BY optimizations
when the WITH ROLLUP modifier is present, and splitting the
const-wrapping part of JOIN::rollup_init() into a separate
method which is now invoked after make_join_statistics() when
the const tables are already known.
subquery returning multiple rows
Error handling was missing when handling subqueires in WHERE
and when assigning a SELECT result to a @variable.
This caused crash(es).
Fixed by adding error handling code to both the WHERE
condition evaluation and to assignment to an @variable.
having clause...
The fix for bug 46184 was not very complete. It was not covering
views using temporary tables and multiple tables in a FROM clause.
Fixed by reverting the fix for 46184 and making a more general
check that is checking at the right execution stage and for all
of the non-supported cases.
Now PROCEDURE ANALYZE on non-top level SELECT is also forbidden.
Updated the analyse.test and subselect.test accordingly.