"load data" statements were written to the binlog as a mix of the original statement
and bits recreated from parse-info. This relied on implementation details and broke
with IGNORE_SPACES and versioned comments.
We now completely resynthesize the query for LOAD DATA for binlog (which among other
things normalizes them somewhat with regard to case, spaces, etc.).
We have already parsed the query properly, so we make use of that rather
than mix-and-match string literals and parsed items.
This should make us safe with regard to versioned comments, even those
spanning multiple tokens. Also no longer affected by IGNORE_SPACES.
view definition
During SHOW CREATE VIEW there is no reason to 'anonymize'
errors that name objects that a user does not have access
to. Moreover it was inconsistently implemented. For example
base tables being referenced from a view appear to be ok,
but not views. The manual on the other hand is clear: If a
user has the privileges SELECT and SHOW VIEW, the view
definition is available to that user, period. The fix
changes the behavior to support the manual.
trigger, merge table
The problem with break statements is that they have very
local effects. Hence a break statement within the inner loop
of a nested-loops join caused execution to proceed to the
next table even though a serious error occurred. The problem
was fixed by breaking out the inner loop into its own
method. The change empowers all errors to terminate the
execution.
The errors that will now halt multi-DELETE execution
altogether are
- triggers returning errors
- handler errors
- server being killed
All statements executed by mysql_upgrade are binlogged and then are replicated to slave.
This will result in some errors. The report of this bug has demonstrated some examples.
Master and slave should be upgraded separately. All statements executed by
mysql_upgrade will not be binlogged.
--write-binlog and --skip-write-binlog options are added into mysql_upgrade.
These options control whether sql statements are binlogged or not.
In RBR, 'DROP TEMPORARY TABLE IF EXISTS...' statement is binlogged when the table
does not exist.
In fact, 'DROP TEMPORARY TABLE ...' statement should never be binlogged in RBR
no matter if the table exists or not.
This patch addresses this by checking whether we are dropping a
temporary table or not, when building the custom drop statement.
failure to cleanup of table
The test case was not dropping a table before exiting (ie, it was
not cleaning itself after execution). In this case, the warning
message stating that the test did not do a proper cleanup was
deterministic (which can be annoying).
I have found other tests cases on which mtr sporadically reports
that they have not cleaned up after execution:
- rpl_ndb_circular
- rpl_failed_optimize
In this case, the master was dropping a table but there was no
synchronization between the slave and the master.
This patch addresses the rpl_ndb_circular_simplex case by adding
the missing DROP table. The other cases are fixed by deploying
the missing sync_slave_with_master instruction.
HA_ERR_WRONG_INDEX
In RBR, disabling keys on slave table will break replication when
updating or deleting a record. When the slave thread tries to
find the row, by searching in the storage engine, it checks
whether the table has a key or not. If it has one, then the slave
thread uses it to search the record.
Nonetheless, the slave only checks whether the key exists or not,
it does not verify if it is active. Should the key be
disabled (eg, DBA has issued an ALTER TABLE ... DISABLE KEYS)
then it will result in error: HA_ERR_WRONG_INDEX.
This patch addresses this issue by making the slave thread also
check whether the key is active or not before actually using it.
Network error happened here, but it can be caused by CR_CONNECTION_ERROR,
CR_CONN_HOST_ERROR, CR_SERVER_GONE_ERROR, CR_SERVER_LOST, ER_CON_COUNT_ERROR,
and ER_SERVER_SHUTDOWN. We just check CR_SERVER_LOST here, so the test fails.
To fix the problem, check all errors that can be cause by the master shutdown.
There is a missing check for memory allocation failure when allocating
memory for the handlerton structure. If the handlerton init function
tries to de-reference the pointer, it will cause a segmentation fault
and crash the server.
This patch fixes the problem by not calling the init function if memory
allocation failed, and instead prints an informative error message and
reports the error to the caller.
Invalid (old?) table or database name in logs
Problem was still not completely fixed, due to
qouting.
This is the server side only fix (in explain_filename),
the change from filename_to_tablename to use explain_filename
in the InnoDB code must be done before the bug is
fixed.
- Create the "dummy" thread joinable and wait for it to
exit before continuing in 'my_thread_global_init'
- This way we know that the pthread library is initialized
by one thread only