Temporary tables may set join->group to 0 even though there is
grouping. Also need to test if sum_func_count>0 when JOIN::exec()
decides whether to present results in a grouped manner.
mysql-test/r/loadxml.result
mysql-test/t/loadxml.test
Fixing non-deterministic test results
sql/sql_yacc.yy
Initializing fname_first using get_tok_end() instead of get_ptr().
The latter is grammar-dependant. The former is not.
columns without where/group
Simple SELECT with implicit grouping used to return many rows if
the query was ordered by the aggregated column in the SELECT
list. This was incorrect because queries with implicit grouping
should only return a single record.
The problem was that when JOIN:exec() decided if execution needed
to handle grouping, it was assumed that sum_func_count==0 meant
that there were no aggregate functions in the query. This
assumption was not correct in JOIN::exec() because the aggregate
functions might have been optimized away during JOIN::optimize().
The reason why queries without ordering behaved correctly was
that sum_func_count is only recalculated if the optimizer chooses
to use temporary tables (which it does in the ordered case).
Hence, non-ordered queries were correctly treated as grouped.
The fix for this bug was to remove the assumption that
sum_func_count==0 means that there is no need for grouping. This
was done by introducing variable "bool implicit_grouping" in the
JOIN object.
Difficult to debug due to lacking report
This does not solve the real issue, but extracts server log when it happens
Forst commit was incomplete, didn't cover all cases
Use ev_offset instead of 1 as the packet header offset when getting
log position from events for heartbeat
call reset_transmit_packet before calling send_heartbeat_event
The BINLOG statement was sharing too much code with the slave SQL thread, introduced with
the patch for Bug#32407. This caused statements to be logged with the wrong server_id, the
id stored inside the events of the BINLOG statement rather than the id of the running
server.
Fix by rearranging code a bit so that only relevant parts of the code are executed by
the BINLOG statement, and the server_id of the server executing the statements will
not be overrided by the server_id stored in the 'format description BINLOG statement'.
The problem was in incorrect handling of predicates involving
NULL as a constant value by the range optimizer.
For example, when creating a SEL_ARG node from a condition of
the form "field < const" (which would normally result in the
"NULL < field < const" SEL_ARG), the special case when "const"
is NULL was not taken into account, so "NULL < field < NULL"
was produced for the "field < NULL" condition.
As a result, SEL_ARG structures of this form could not be
further optimized which in turn could lead to incorrectly
constructed SEL_ARG trees. In particular, code assuming SEL_ARG
structures to always form a sequence of ordered disjoint
intervals could enter an infinite loop under some
circumstances.
Fixed by changing get_mm_leaf() so that for any sargable
predicate except "<=>" involving NULL as a constant, "empty"
SEL_ARG is returned, since such a predicate is always false.
Add an option to control whether the master should keep waiting
until timeout when it detected that there is no semi-sync slave
available.
The bool option 'rpl_semi_sync_master_wait_no_slave' is 1 by
defalt, and will keep waiting until timeout. When set to 0, the
master will switch to asynchronous replication immediately when
no semi-sync slave is available.
Semi-sync status were not reset by FLUSH STATUS, this was because
all semi-sync status variables are defined as SHOW_FUNC and FLUSH
STATUS could only reset SHOW_LONG type variables.
This problem is fixed by change all status variables that should
be reset by FLUSH STATUS from SHOW_FUNC to SHOW_LONG.
After the fix, the following status variables will be reset by
FLUSH STATUS:
Rpl_semi_sync_master_yes_tx
Rpl_semi_sync_master_no_tx
Note: normally, FLUSH STATUS itself will be written into binlog
and be replicated, so after FLUSH STATS, one of
Rpl_semi_sync_master_yes_tx
Rpl_semi_sync_master_no_tx
can be 1 dependent on the semi-sync status. So it's recommended
to use FLUSH NO_WRITE_TO_BINLOG STATUS to avoid this.