Commit graph

6 commits

Author SHA1 Message Date
He Zhenxing
b6529a140b Add semi-sync support for Windows 2009-10-23 12:56:30 +08:00
He Zhenxing
dab1162b53 Backport post fix for semisync
Remove functions that no longer needed
Fix warning suppressions
2009-10-12 21:21:13 +08:00
He Zhenxing
b92ec52915 Backport BUG#47298 Semisync: always wait until timeout if no semi-sync slave available
Add an option to control whether the master should keep waiting
until timeout when it detected that there is no semi-sync slave
available.

The bool option 'rpl_semi_sync_master_wait_no_slave' is 1 by
defalt, and will keep waiting until timeout. When set to 0, the
master will switch to asynchronous replication immediately when
no semi-sync slave is available.
2009-10-12 21:15:32 +08:00
He Zhenxing
64fc766c93 BUG#45674 FLUSH STATUS does not reset semisynchronous counters
Semi-sync status were not reset by FLUSH STATUS, this was because
all semi-sync status variables are defined as SHOW_FUNC and FLUSH
STATUS could only reset SHOW_LONG type variables.

This problem is fixed by change all status variables that should
be reset by FLUSH STATUS from SHOW_FUNC to SHOW_LONG.

After the fix, the following status variables will be reset by
FLUSH STATUS:
  Rpl_semi_sync_master_yes_tx
  Rpl_semi_sync_master_no_tx

Note: normally, FLUSH STATUS itself will be written into binlog
and be replicated, so after FLUSH STATS, one of
  Rpl_semi_sync_master_yes_tx
  Rpl_semi_sync_master_no_tx
can be 1 dependent on the semi-sync status. So it's recommended
to use FLUSH NO_WRITE_TO_BINLOG STATUS to avoid this.
2009-10-12 21:03:04 +08:00
He Zhenxing
55842061e7 Backport BUG#45848 Semisynchronous replication internals are visible in SHOW PROCESSLIST and logs
Semi-sync uses an extra connection from slave to master to send
replies, this is a normal client connection, and used a normal
SET query to set the reply information on master, which is visible
to user and may cause some confusion and complaining.

This problem is fixed by using the method of sending reply by
using the same connection that is used by master dump thread to
send binlog to slave. Since now the semi-sync plugins are integrated
with the server code, it is not a problem to use the internal net
interfaces to do this.

The master dump thread will mark the event requires a reply and
wait for the reply when the event just sent is the last event
of a transaction and semi-sync status is ON; And the slave will
send a reply to master when it received such an event that requires
a reply.
2009-10-12 20:55:01 +08:00
He Zhenxing
7771b90295 Back porting the test case for semi-sync 2009-09-30 16:09:31 +08:00