time per connection
Removed const_string() method from Item_string (it was only used in one
place, in a bad way). Defer possible SP variable, and access data directly
instead, in date_format item.
- Added empty constructors and virtual destructors to many classes and structs
- Removed some usage of the offsetof() macro to instead use C++ class pointers
If item->cached_table is set, find_field_in_tables() returns found field
even if it doesn't belong to current select. Because Item_field::fix_fields
doesn't expect such behaviour, reported bug occurs.
Item_field::fix_fields() was modifed to detect when find_field_in_tables()
can return field from outer select and process such fields accordingly.
In order to ease this code which was searching and processing outed fields was
moved into separate function called Item_field::fix_outer_field().
- BUG#15166: Wrong update permissions required to execute triggers
- BUG#15196: Wrong select permission required to execute triggers
The idea of the fix is to check necessary privileges
in Item_trigger_field::fix_fields(), instead of having "special variables"
technique. To achieve this, we should pass to an Item_trigger_field instance
a flag, which will indicate the usage/access type of this trigger variable.
- Fixed tests
- Optimized new code
- Fixed some unlikely core dumps
- Better bug fixes for:
- #14397 - OPTIMIZE TABLE with an open HANDLER causes a crash
- #14850 (ERROR 1062 when a quering a view using a Group By on a column that can be null
to Crash": the bug was that due to non-standard name
resolution precedence in stored procedures (See Bug#5967)
a stored procedure variable took precedence over a table column
when the arguments for VALUES() function were resolved.
The implementation of VALUES() function was not designed to work
with Item_splocal and crashed.
VALUES() function is non-standard. It can refer to, and
is meaningful for, table columns only. The patch disables SP
variables as possible arguments of VALUES() function.
according to the standard.
The idea is to use Field-classes to implement stored routines
variables. Also, we should provide facade to Item-hierarchy
by Item_field class (it is necessary, since SRVs take part
in expressions).
The patch fixes the following bugs:
- BUG#8702: Stored Procedures: No Error/Warning shown for inappropriate data
type matching;
- BUG#8768: Functions: For any unsigned data type, -ve values can be passed
and returned;
- BUG#8769: Functions: For Int datatypes, out of range values can be passed
and returned;
- BUG#9078: STORED PROCDURE: Decimal digits are not displayed when we use
DECIMAL datatype;
- BUG#9572: Stored procedures: variable type declarations ignored;
- BUG#12903: upper function does not work inside a function;
- BUG#13705: parameters to stored procedures are not verified;
- BUG#13808: ENUM type stored procedure parameter accepts non-enumerated
data;
- BUG#13909: Varchar Stored Procedure Parameter always BINARY string (ignores
CHARACTER SET);
- BUG#14161: Stored procedure cannot retrieve bigint unsigned;
- BUG#14188: BINARY variables have no 0x00 padding;
- BUG#15148: Stored procedure variables accept non-scalar values;
if inner routine has more local variables than outer one, and
one of its last variables was used as argument to NOT operator".
THD::spcont was non-0 when we were parsing stored routine/trigger
definition during execution of another stored routine. This confused
methods of Item_splocal and forced them use wrong runtime context.
Fix ensures that we always have THD::spcont equal to zero during
routine/trigger body parsing. This also allows to avoid problems
with errors which occur during parsing and SQL exception handlers.
Bad examples of usage of a string with its length fixed.
The incorrect length in the trigger file configuration descriptor
fixed (BUG#14090).
A hook for unknown keys added to the parser to support old .TRG files.
Invalid date like 2000-02-32 wasn't converted to int, which lead to not
using index and comparison with field as astring, which results in slow
query execution.
convert_constatn_item() and get_mm_leaf() now forces MODE_INVALID_DATES to
allow such conversion.
- CHAR() now returns binary string as default
- CHAR(X*65536+Y*256+Z) is now equal to CHAR(X,Y,Z) independent of the character set for CHAR()
- Test for both ETIMEDOUT and ETIME from pthread_cond_timedwait()
(Some old systems returns ETIME and it's safer to test for both values
than to try to write a wrapper for each old system)
- Fixed new introduced bug in NOT BETWEEN X and X
- Ensure we call commit_by_xid or rollback_by_xid for all engines, even if one engine has failed
- Use octet2hex() for all conversion of string to hex
- Simplify and optimize code
Ensure that ccache is also used for C programs
mysql: Ensure that 'delimiter' works the same way in batch mode as in normal mode
mysqldump: Change to use ;; (instead of //) as a stored procedure/trigger delimiter
Fixed test cases by adding missing DROP's and rename views to be of type 'v#'
Removed MY_UNIX_PATH from fn_format()
Removed current_db_used from TABLE_LIST
Removed usage of 'current_thd' in Item_splocal
Removed some compiler warnings
A bit faster longlong2str code
The problem was then when a column reference was resolved to a view column, the new Item
created for this column contained the name of the view, and not the view alias.
Fields of view represented by Item_direct_view_ref. When complex expression
such as if(sum()>...,...) is splited in simpler parts by refs was ignored.
Beside this direct ref doesn't use it's result_field and thus can't store
it's result in tmp table which is needed for sum() ... group.
All this results in reported bug.
Item::split_sum_func2() now converts Item_direct_view_ref to Item_ref to
make fields from view being storable in tmp table.