The test result differs on windows, since
it writes out 'localhost:<port>' instead of
only 'localhost', since it uses tcp/ip instead
of unix sockets on windows.
Fixed by replacing that column.
Also requires --big-test from some long running tests
and added a weekly run of all test requiring --big-test.
mysql-test/collections/default.weekly:
Added a run of big-test (already exists in 5.5).
mysql-test/r/variables-big.result:
Updated results
mysql-test/suite/parts/t/part_supported_sql_func_innodb.test:
requiring --big-test since the test takes long time
mysql-test/suite/parts/t/partition_alter1_1_2_innodb.test:
requiring --big-test since the test takes long time
mysql-test/suite/parts/t/partition_alter1_2_innodb.test:
requiring --big-test since the test takes long time
mysql-test/suite/parts/t/partition_alter4_innodb.test:
requiring --big-test since the test takes long time
mysql-test/t/disabled.def:
Disabled two tests since they fail and was already
reported as bugs (but was never run since they requires
--big-test flag).
mysql-test/t/variables-big.test:
Replacing column 3 in process list since it
is not the same on windows as in unix.
The enum system variables were handled inconsistently
as ints, unsigned int and unsigned long on various places.
This caused problems on platforms on which
sizeof(int) != sizeof(long).
Fixed by homogenizing the type of the enum variables
to unsigned int, since it's size compatible with the C enum
type.
Removed the test from the experimental list.
The 'rpl_get_master_version_and_clock' test verifies if the slave I/O
thread tries to reconnect to master when it tries to get the values of
the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection.
So the master server is restarted for making the transient network
disconnection, during the period the COM_REGISTER_SLAVE failures are
produced in server log file when the slave I/O thread tries to
register on master.
To fix the problem, suppress COM_REGISTER_SLAVE failures in server log
file by mtr suppression, because they are expected.
mysql-test/suite/rpl/r/rpl_get_master_version_and_clock.result:
Removed mtr.add_suppression("Get master clock failed with error: ")
and mtr.add_suppression("Get master SERVER_ID failed with error: ").
Because they are suppressed globally.