VARIABLE_VALUE field is decreased to 1024 symbols.
(affected I_S tables: GLOBAL_VARIABLES, SESSION_VARIABLES,
GLOBAL_STATUS, SESSION_STATUS).
The only variable which can be longer than 1024 is
init_connect. The variable will be truncated with warning.
Additional fix:
Added where condition filter which speed up queries which
have where condition with expressions which use VARIABLE_NAME
field.
changed 'charset', 'collation' field length from 64 to MY_CS_NAME_SIZE(32)
in tables:
SCHEMATA, TABLES, COLUMNS, CHARACTER_SETS,
COLLATIONS, COLLATION_CHARACTER_SET_APPLICABILITY
Innodb monitor could cause a server crash because of invalid access to a
shared variable in a concurrent environment.
This patch adds a guard to protect against crashes but not against
inconsistent values because of performance reasons.
The convert_constant_item function converts a constant to integer using
field for condition like 'field = a_constant'. In some cases the
convert_constant_item is called for a subquery when outer select is already
being executed, so convert_constant_item saves field's value to prevent its
corruption. For EXPLAIN and at the prepare phase field's value isn't
initialized yet, thus when convert_constant_item tries to restore saved
value it fails assertion.
Now the convert_constant_item doesn't save/restore field's value if it's
haven't been read yet. Outer constant values are always saved.
order by
Problem was that the first index read was unordered,
and the next was ordered, resulting in use of
uninitialized data.
Solution was to use the correct variable to see if
the 'next' call should be ordered or not.
The partitioning clause is only a very long single line, which is very
hard to interpret for a human. This patch breaks the partitioning
syntax into one line for the partitioning type, and one line per
partition/subpartition.
TRUNCATE TABLE for InnoDB tables returned a count showing an approximation
of the number of rows affected to gain efficiency.
Now the statement always returns 0 rows affected for clarity.
When statement-based replication is used, and the
transaction isolation level is READ-COMMITTED or stricter,
InnoDB will print an error because statement-based
replication might lead to inconsistency between master
and slave databases. However, when the binary log is not
engaged, this is not an issue and an error should
not be printed.
This patch makes thd_binlog_format() return BINLOG_FORMAT_
UNSPEC when the binary log is not engaged for the given
thread.
Problem was that partitioning cached the table flags.
These flags could change due to TRANSACTION LEVEL changes.
Solution was to remove the cache and always return the table flags
from the first partition (if the handler was initialized).
A string buffers which were included in the 'view' data structure
were allocated on the stack, causing an invalid pointer when used
after the function returned.
The fix: use copy of values for view->md5 & view->queries
The convert_constant_item function converts a constant to integer using
field for condition like 'field = a_constant'. When the convert_constant_item
is called for a subquery the outer select is already being executed, so
convert_constant_item saves field's value to prevent its corruption.
For EXPLAIN field's value isn't initialized thus when convert_constant_item
tries to restore saved value it fails assertion.
Now the convert_constant_item doesn't save/restore field's value
for EXPLAIN.
Problem: mysqld doesn't detect that enum data must be reinserted performing
'ALTER TABLE' in some cases.
Fix: reinsert data altering an enum field if enum values are changed.
- Make send_row_on_empty_set() return FALSE when simplify_cond() has found out
that HAVING is always FALSE
re-committing to put the fix into 5.0 and 5.1
breaks auto increment
The auto_increment value was not initialized if
the first statement after opening a table was
an 'UPDATE'.
solution was to check initialize if it was not,
before trying to increase it in update.