The problem was that appending values to the end of an existing
ENUM or SET column was being treated as table data modification,
preventing a immediately (fast) table alteration that occurs when
only table metadata is being modified.
The cause was twofold: adding a enumeration or set members to the
end of the list of valid member values was not being considered
a "compatible" table alteration, and for SET columns, the check
was being done upon the max display length and not the underlying
(pack) length of the field.
The solution is to augment the function that checks wether two ENUM
or SET fields are compatible -- by comparing the pack lengths and
performing a limited comparison of the member values.
The bug is not related to MERGE table or TRIGGER. More correct description
would be 'assertion on multi-table UPDATE + NATURAL JOIN + MERGEABLE VIEW'.
On PREPARE stage(see test case) we call mark_common_columns() func which
creates ON condition for NATURAL JOIN and sets appropriate
table read_set bitmaps for fields which are used in ON condition.
On EXECUTE stage mark_common_columns() is not called, we set
necessary read_set bitmaps in setup_conds(). But 'B.f1' field
is already processed and related item alredy fixed before
setup_conds() as updated field and setup_conds can not set
read_set bitmap because of that.
The fix is to set read_set bitmap for appropriate table field even
if Item_direct_view_ref item which represents a refernce to this field
is fixed.
"load data" statements were written to the binlog as a mix of the original statement
and bits recreated from parse-info. This relied on implementation details and broke
with IGNORE_SPACES and versioned comments.
We now completely resynthesize the query for LOAD DATA for binlog (which among other
things normalizes them somewhat with regard to case, spaces, etc.).
We have already parsed the query properly, so we make use of that rather
than mix-and-match string literals and parsed items.
This should make us safe with regard to versioned comments, even those
spanning multiple tokens. Also no longer affected by IGNORE_SPACES.
view definition
During SHOW CREATE VIEW there is no reason to 'anonymize'
errors that name objects that a user does not have access
to. Moreover it was inconsistently implemented. For example
base tables being referenced from a view appear to be ok,
but not views. The manual on the other hand is clear: If a
user has the privileges SELECT and SHOW VIEW, the view
definition is available to that user, period. The fix
changes the behavior to support the manual.
trigger, merge table
The problem with break statements is that they have very
local effects. Hence a break statement within the inner loop
of a nested-loops join caused execution to proceed to the
next table even though a serious error occurred. The problem
was fixed by breaking out the inner loop into its own
method. The change empowers all errors to terminate the
execution.
The errors that will now halt multi-DELETE execution
altogether are
- triggers returning errors
- handler errors
- server being killed
In RBR, 'DROP TEMPORARY TABLE IF EXISTS...' statement is binlogged when the table
does not exist.
In fact, 'DROP TEMPORARY TABLE ...' statement should never be binlogged in RBR
no matter if the table exists or not.
This patch addresses this by checking whether we are dropping a
temporary table or not, when building the custom drop statement.
HA_ERR_WRONG_INDEX
In RBR, disabling keys on slave table will break replication when
updating or deleting a record. When the slave thread tries to
find the row, by searching in the storage engine, it checks
whether the table has a key or not. If it has one, then the slave
thread uses it to search the record.
Nonetheless, the slave only checks whether the key exists or not,
it does not verify if it is active. Should the key be
disabled (eg, DBA has issued an ALTER TABLE ... DISABLE KEYS)
then it will result in error: HA_ERR_WRONG_INDEX.
This patch addresses this issue by making the slave thread also
check whether the key is active or not before actually using it.
Invalid (old?) table or database name in logs
Problem was still not completely fixed, due to
qouting.
This is the server side only fix (in explain_filename),
the change from filename_to_tablename to use explain_filename
in the InnoDB code must be done before the bug is
fixed.
when compiled with Sun Studio compiler).
The thing is that Sun Studio compiler calls destructor of stack
objects when pthread_exit() is called. That triggered an assertion
in DBUG_ENTER()/DBUG_RETURN() validation logic (if DBUG_ENTER() is
used in the beginning of function, all returns should be replaced
by DBUG_RETURN/DBUG_VOID_RETURN macros).
A fix is to explicitly use DBUG_LEAVE macro.
The "socket" variable is not available on Windows even though
the --socket option can be used to specify the pipe name for
local connections that use a named pipe.
The solution is to ensure that the variable is always defined.
checksum)"
The problem was that checksum of GEOMETRY type used memory addresses
in the computation, making it un-repeatable thus useless.
(This patch is a backport from 6.0 branch)
Despite copying the value of the old table's row type
we don't always have to mark row type as being specified.
Innodb uses this to check if it can do fast ALTER TABLE
or not.
Fixed by correctly flagging the presence of row_type
only when it's actually changed.
Added a test case for 39200.
query
The fix for bug 46749 removed the check for OUTER_REF_TABLE_BIT
and substituted it for a check on the presence of
Item_ident::depended_from.
Removing it altogether was wrong : OUTER_REF_TABLE_BIT should
still be checked in addition to depended_from (because it's not
set in all cases and doesn't contradict to the check of depended_from).
Fixed by returning the old condition back as a compliment to the
new one.
But there is no Last_IO_Error reported.
On the master, if a binary log event is larger than max_allowed_packet,
ER_MASTER_FATAL_ERROR_READING_BINLOG and the specific reason of this error is
sent to a slave when it requests a dump from the master, thus leading
the I/O thread to stop.
On a slave, the I/O thread stops when receiving a packet larger than max_allowed_packet.
In both cases, however, there was no Last_IO_Error reported.
This patch adds code to report the Last_IO_Error and exact reason before stopping the
I/O thread and also reports the case the out memory pops up while
handling packets from the master.
"insert into.. select * from"
When inserting into a partitioned table using 'insert into
<target> select * from <src>', read_buffer_size bytes of memory
are allocated for each partition in the target table.
This resulted in large memory consumption when the number of
partitions are high.
This patch introduces a new method which tries to estimate the
buffer size required for each partition and limits the maximum
buffer size used to maximum of 10 * read_buffer_size,
11 * read_buffer_size in case of monotonic partition functions.
When parsing the service installation parameter in
default_service_handling() make sure the value of the
optional parameter doesn't overwrite it's name.
Problem: LOGGER::general_log_write() relied on valid "thd" parameter passed
but had inconsistent "if (thd)" check.
Fix: as we always pass a valid "thd" parameter to the method,
redundant check removed.
The problem is that argument buffer can be used as result buffer
and it leads to argument value change.
The fix is to use 'old buffer' as result buffer only
if first argument is not constant item.
In RBR, There is an inconsistency between slaves and master.
When INSERT statement which includes an auto_increment field is executed,
Store engine of master will check the value of the auto_increment field.
It will generate a sequence number and then replace the value, if its value is NULL or empty.
if the field's value is 0, the store engine will do like encountering the NULL values
unless NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
In contrast, if the field's value is 0, Store engine of slave always generates a new sequence number
whether or not NO_AUTO_VALUE_ON_ZERO is set into SQL_MODE.
SQL MODE of slave sql thread is always consistency with master's.
Another variable is related to this bug.
If generateing a sequence number is decided by the values of
table->auto_increment_field_not_null and SQL_MODE(if includes MODE_NO_AUTO_VALUE_ON_ZERO)
The table->auto_increment_is_not_null is FALSE, which causes this bug to appear. ..
Create temporary InnoDB table fails on case insensitive
filesystems, when lower_case_table_names is 2 (e.g. OS X)
and temporary directory path contains upper case letters.
The problem was that tmpdir prefix was converted to lower
case when table was created, but was passed as is when
table was opened.
Fixed by leaving tmpdir prefix part intact.