The 'BEGIN/COMMIT/ROLLBACK' log event could be filtered out if the
database is not selected by --database option of mysqlbinlog command.
This can result in problem if there are some statements in the
transaction are not filtered out.
To fix the problem, mysqlbinlog will output 'BEGIN/ROLLBACK/COMMIT'
in regardless of the database filtering rules.
The 'BEGIN/COMMIT/ROLLBACK' log event could be filtered out if the
database is not selected by --database option of mysqlbinlog command.
This can result in problem if there are some statements in the
transaction are not filtered out.
To fix the problem, mysqlbinlog will output 'BEGIN/ROLLBACK/COMMIT'
in regardless of the database filtering rules.
"load data" statements were written to the binlog as a mix of the original statement
and bits recreated from parse-info. This relied on implementation details and broke
with IGNORE_SPACES and versioned comments.
We now completely resynthesize the query for LOAD DATA for binlog (which among other
things normalizes them somewhat with regard to case, spaces, etc.).
We have already parsed the query properly, so we make use of that rather
than mix-and-match string literals and parsed items.
This should make us safe with regard to versioned comments, even those
spanning multiple tokens. Also no longer affected by IGNORE_SPACES.
The --hexdump option crashed mysqlbinlog when used together
with the --read-from-remote-server option due to use of
uninitialized memory.
Since Log_event::print_header() relies on temp_buf to be
initialized when the --hexdump option is present,
dump_remote_log_entries() was fixed to setup temp_buf to point
to the start of a binlog event as done in
dump_local_log_entries().
The root cause of this bug is identical to the one for
bug #17654. The latter was fixed in 5.1 and up, so this
patch is backport of the patches for bug #17654 to 5.0.
Only 5.0 needs a changelog entry.
+ Fix for Bug#43114 wait_until_count_sessions too restrictive, random PB failures
+ Removal of a lot of other weaknesses found
+ modifications according to review
Signed integer format specifier forced to print the binlog header with server_id
negative if the unsigned value sets the sign-bit ON.
Fixed with correcting the specifier to correspond to typeof(server_id) == ulong.
Replaced Unix calls with mysql-test-run's built-in functions / SQL manipulation where possible.
Replaced error codes with error names as well.
Disabled two tests on Windows due to more complex Unix command usage
See Bug#41307, Bug#41308
slave
The stored-routine code took the contents of the (lowest) parser
and copied it directly to the binlog, which causes problems if there
is a special case of interpretation at the parser level -- which
there is, in the "/*!VER */" comments. The trailing "*/" caused
errors on the slave, naturally.
Now, since by that point we have /properly/ created parse-tree (as
the rest of the server should do!) for the stored-routine CREATE, we
can construct a perfect statement from that information, instead of
writing uncertain information from an unknown parser state.
Fortunately, there's already a function nearby that does exactly
that.
---
Update for Bug#36570. Qualify routine names with db name when
writing to the binlog ONLY if the source text is qualified.
Problem: a typo in the code. When autocommit, foreign_key_checks,
sql_auto_is_null, or unique_checks changes, it prints "SET", and then a
comma-separated list of assignments. However, it does not print the
assignment to the @@autocommit variable.
Fix: print the @@autocommit variable.
Problem: in mixed and statement mode, a query that refers to a
system variable will use the slave's value when replayed on
slave. So if the value of a system variable is inserted into a
table, the slave will differ from the master.
Fix: mark statements that refer to a system variable as "unsafe",
meaning they will be replicated by row in mixed mode and produce a warning
in statement mode. There are some exceptions: some variables are actually
replicated. Those should *not* be marked as unsafe.
BUG#34732: mysqlbinlog does not print default values for auto_increment variables
Problem: mysqlbinlog does not print default values for some variables,
including auto_increment_increment and others. So if a client executing
the output of mysqlbinlog has different default values, replication will
be wrong.
Fix: Always print default values for all variables that are replicated.
I need to fix the two bugs at the same time, because the test cases would
fail if I only fixed one of them.
fine
The reason of this bug is that when mysqlbinlog dumps a query, the query is written to
output with a delimeter appended right after it, if the query string ends with a '--'
comment, then the delimeter would be considered as part of the comment, if there are any
statements after this query, then it will cause a syntax error.
Start a newline before appending delimiter after a query string
The reason of this bug is that when mysqlbinlog dumps a query, the query is written to
output with a delimeter appended right after it, if the query string ends with a '--'
comment, then the delimeter would be considered as part of the comment, if there are any
statements after this query, then it will cause a syntax error.
Start a newline before appending delimiter after a query string
The client program 'mysqlbinlog' crashed when trying to print a User_var_log_event holding
a floating-point value since the format specifier for my_b_printf() does not support
floating-point format specifiers.
This patch prints the floating-point number to an internal buffer, and then writes
that buffer to the output instead.
When running mysqlbinlog on a 64-bit machine with a corrupt relay log,
it causes mysqlbinlog to crash. In this case, the crash is caused
because a request for 18446744073709534806U bytes is issued, which
apparantly can be served on a 64-bit machine (speculatively, I assume)
but this causes the memcpy() issued later to copy the data to segfault.
The request for the number of bytes is caused by a computation
of data_len - server_vars_len where server_vars_len is corrupt in such
a sense that it is > data_len. This causes a wrap-around, with the
the data_len given above.
This patch adds a check that if server_vars_len is greater than
data_len before the substraction, and aborts reading the event in
that case marking the event as invalid. It also adds checks to see
that reading the server variables does not go outside the bounds
of the available space, giving a limited amount of integrity check.
restores from mysqlbinlog out
Problem: using "mysqlbinlog | mysql" for recoveries the connection_id()
result may differ from what was used when issuing the statement.
Fix: if there is a connection_id() in a statement, write to binlog
SET pseudo_thread_id= XXX; before it and use the value later on.
Occasionally mysqlbinlog --hexdump failed with error:
ERROR 1064 (42000) at line ...: You have an error in your
SQL syntax; check the manual that corresponds to your MySQL
server version for the right syntax to use near
'Query thread_id=... exec_time=... error_code=...
When the length of hexadecimal dump of binlog header was
divisible by 16, commentary sign '#' after header was lost.
The Log_event::print_header function has been modified to always
finish hexadecimal binlog header with "\n# ".