Problem: Some system functions that could return different values on
master and slave were not marked unsafe. In particular:
GET_LOCK
IS_FREE_LOCK
IS_USED_LOCK
MASTER_POS_WAIT
RELEASE_LOCK
SLEEP
SYSDATE
VERSION
Fix: Mark these functions unsafe.
The test failed originally -- did not reset binlogging - for the reason
identified by bug@15580.
However it never can be run on the embedded platfrom for yet another cause -
the embedded can not KILL query.
Comments added to the test particularly relating `reset master'
to the mentioned bug.
Problem: mysqlbinlog does not free memory if an error happens.
Fix: binlog-processing functions do not call exit() anymore. Instead, they
print an error and return an error code. Error codes are propagated all
the way back to main, and all allocated memory is freed on the way.