It's a regression issue.
The reason of the bug appeared to be an error introduced into 5.1 source code.
A piece of code in Create_file_log_event::do_apply_event() did not have test
coverage which made make test and pb unaware.
Fixed with inverting the old value of the return value from
Create_file_log_event::do_apply_event().
The rpl test suite is extended with `rpl_cross_version' the file to hold
regression cases similar to the current.
clause server fires immediately after creating event and time between create and delete
event sometimes is enough for firing. So adding STARTS clause moves first execution in
future after drop of event
1. Added STARTS clause for CREATE EVENT.
2. Updated result file.
The next number (AUTO_INCREMENT) field of the table for write
rows events are not initialized, and cause some engines (innodb)
not correctly update the tables's auto_increment value.
This patch fixed this problem by honor next number fields if present.
Added cleanup of status variables to the end of binlog_database.
Re-recorded .result file to account for cleanup statement.
NOTE: binlog.binlog_innodb also has had an FLUSH STATUS; statement added to it as well, but
adding this cleanup as a preventative measure.
The binlog_innodb test was sensitive to what tests ran before it. Now run
FLUSH STATUS before performing operations that need to be checked.
sys_var_thd_ulong::update() was improperly casting an option value from
ulonglong to ulong before comparing it to the max allowed value. On systems
where ulong and ulonglong are of different size, this caused values greater
than ULONG_MAX to wrap around (not be truncated to ULONG_MAX, which appears to
have been the intention of the original coder), and caused some checks to work
incorrectly. This wasn't generally visible to the user, because later checks
would prevent the wrapped-around value from being used. But it caused warning
messages to differ between 32- and 64-bit platforms. Fix is to just remove the
cast. Also added a DBUG_ASSERT to ensure that the value really is capped
properly before finally stuffing it into the ulong.
Problem: When an Incident_log_event contains a bad incident number on disk,
the server crashes with an assertion.
Fix: Don't validate input with assertions. Use errors.
Static disabled plugins|engines and dynamic plugins which installed but disabled
are not visible in I_S PLUGINS|ENGINES tables because they are not stored into
global plugin array.
The fix: add such plugins|engines to plugin array with PLUGIN_IS_DISABLED status.
I_S.ENGINES 'Transactions', 'XA', 'Savepoints' fields have NULL value in this case.
binlog_row_mix_innodb_myisam resutls are corrected.
The last operations prior the dup error is
TRUNCATE table t2;
Therefore after
--error ER_DUP_ENTRY
INSERT INTO t2 select * from t1;
table t2 must be empty, and that is what the updated results confirm.
- remove totally wrong (syntax) entries from disabled.def
- remove entries belonging to deleted tests from disabled.def
- correct the comments (correct the bug mentioned) of entries in disabled.def
- remove never completed tests which were accidently pushed
BUG#39325 Server crash inside MYSQL_LOG::purge_first_log halts replicaiton
The patch reverses the order of the purging and updating events for log and
relay-log.info/index files respectively.
This solves the problem of having holes caused by crashes happening between updating
info/index files and purging logs.
This patch also contains an aditional test case for testing the crashing before purge logs.
NOTE1: This is a combined patch for BUG#38826 and BUG#39325. This patch is based on
bugteam tree and takes into account reviewers suggestions.
NOTE2: Merge from 5.0-bugteam
'lock wait timeout exceeded'
Problem was a bug in the implementation of scan in partitioning
which masked the error code from the partition's handler.
Fixed by returning the value from the underlying handler.
Altered param_check to disable warnings on system-sensitive operations
and added some notes / possible TODO
Re-recorded.result file to account for change
after rollback on master
When starting a transaction with a statement containing changes
to both transactional tables and non-transactional tables, the
statement is considered as non-transactional and is therefore
written directly to the binary log. This behaviour was present
in 5.0, and has propagated to 5.1.
If a trigger containing a change of a non-transactional table is
added to a transactional table, any changes to the transactional
table is "tainted" as non-transactional.
This patch solves the problem by removing the existing "hack" that
allows non-transactional statements appearing first in a transaction
to be written directly to the binary log. Instead, anything inside
a transaction is treaded as part of the transaction and not written
to the binary log until the transaction is committed.
A transaction could result in having an extra event after a query that
errored e.g because of a dup key. Such a query is rolled back in
innodb, as specified, but has not been in binlog.
It appeares that the binlog engine did not always register for a query
(statement) because the previous query had not reset at its statement
commit time. Because of that fact there was no roll-back to the
trx_data->before_stmt_pos position and a the pending event of the
errorred query could become flushed to the binlog file.
Fixed with deploying the reset of trx_data->before_stmt_pos at the end
of the query processing.
The minimum value differs depending on the OS and mysqld build, so that the test fail spradically.
The check of this value has been changed from check of concrete values to the check of a range that is near by the expected value.
which were determined by the server depending on the os. The solution is to disable warnings in general.
The check of the values only have been done for Linux and Windows. Now, the check has been changed to the check of
ranges (not more concrete values) being near by the expected (set) values.
VARIABLE_VALUE field is decreased to 1024 symbols.
(affected I_S tables: GLOBAL_VARIABLES, SESSION_VARIABLES,
GLOBAL_STATUS, SESSION_STATUS).
The only variable which can be longer than 1024 is
init_connect. The variable will be truncated with warning.
Additional fix:
Added where condition filter which speed up queries which
have where condition with expressions which use VARIABLE_NAME
field.
changed 'charset', 'collation' field length from 64 to MY_CS_NAME_SIZE(32)
in tables:
SCHEMATA, TABLES, COLUMNS, CHARACTER_SETS,
COLLATIONS, COLLATION_CHARACTER_SET_APPLICABILITY