Pushbuild fixes:
- Make MAX_SEL_ARGS smaller (even 16K records_in_range() calls is
more than it makes sense to do in typical cases)
- Don't call sel_arg->test_use_count() if we've already allocated
more than MAX_SEL_ARGs elements. The test will succeed but will take
too much time for the test suite (and not provide much value).
NO_AUTO_VALUE_ON_ZERO mode.
In the NO_AUTO_VALUE_ON_ZERO mode the table->auto_increment_field_not_null
variable is used to indicate that a non-NULL value was specified by the user
for an auto_increment column. When an INSERT .. ON DUPLICATE updates the
auto_increment field this variable is set to true and stays unchanged for the
next insert operation. This makes the next inserted row sometimes wrongly have
0 as the value of the auto_increment field.
Now the fill_record() function resets the table->auto_increment_field_not_null
variable before filling the record.
The table->auto_increment_field_not_null variable is also reset by the
open_table() function for a case if we missed some auto_increment_field_not_null
handling bug.
Now the table->auto_increment_field_not_null is reset at the end of the
mysql_load() function.
Reset the table->auto_increment_field_not_null variable after each
write_row() call in the copy_data_between_tables() function.
Adding an event that can be used to denote that an incident occured
on the master. The event can be used to denote a gap in the replication
stream, but can also be used to denote other incidents.
In addition, the injector interface is extended with functions to
generate an incident event. The function will also rotate the binary
log after generating an incident event to get a fresh binary log.
- Added PARAM::alloced_sel_args where we count the # of SEL_ARGs
created by SEL_ARG tree cloning operations.
- Made the range analyzer to shortcut and not do any more cloning
if we've already created MAX_SEL_ARGS SEL_ARG objects in cloning.
- Added comments about space complexity of SEL_ARG-graph
representation.
Problem: SOUNDEX returned an invalid string for international
characters in multi-byte character sets.
For example: for a Chinese/Japanese 3-byte long character
_utf8 0xE99885 it took only the very first byte 0xE9,
put it into the outout string and then appended with three
DIGIT ZERO characters, so the result was 0xE9303030 - which
is an invalide utf8 string.
Fix: make SOUNDEX() multi-byte aware and - put only complete
characters into result, thus return only valid strings.
This patch also makes SOUNDEX() compatible with UCS2.
Geometry fields have a result type string and a
special subclass to cater for the differences
between them and the base class (just like
DATE/TIME).
When creating temporary tables for results of
functions that return results of type GEOMETRY
we must construct fields of the derived class
instead of the base class.
Fixed by creating a GEOMETRY field (Field_geom)
instead of a generic BLOB (Field_blob) in temp
tables for the results of GIS functions that
have GEOMETRY return type (Item_geometry_func).