The 'rpl_get_master_version_and_clock' test verifies if the slave I/O
thread tries to reconnect to master when it tries to get the values of
the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection.
So the master server is restarted for making the transient network
disconnection. Restarting master server can bring two problems as following:
1. The time out error is encountered sporadically. The slave I/O thread tries
to reconnect master ten times, which is set in my.cnf. So in the test
framework sporadically the slave I/O thread really stoped when it can't
reconnect to master in the ten times successfully before the master starts,
then the time out error will be encountered while waiting for the slave to
start.
2. These warnings and errors are produced in server log file when
the slave I/O thread tries to get the values of the UNIX_TIMESTAMP,
SERVER_ID from master under the transient network disconnection.
To fix problem 1, increase the master retry count to sixty times,
so that the slave I/O thread has enough time to reconnect master
successfully.
To fix problem 2, suppress these warnings and errors by mtr suppression,
because they are expected.
binlog, replication aborts
In SBR or MBR, the schema name is not being written to the binlog
when executing a LOAD DATA statement. This becomes a problem when
the current database (lets call it db1) is different from the
table's schema (lets call it db2). For instance, take the
following statements:
use db1;
load data local infile 'infile.txt' into table db2.t
Should this statement be logged without t's schema (db2), when
replaying it, one can get db1.t populated instead of db2.t (if
db1.t exists). On the other hand, if there is no db1.t at all,
replication will stop.
We fix this by always logging the table (in load file) with fully
qualified name when its schema is different from the current
database or when no default database was selected.
Conflicts
=========
Text conflict in .bzr-mysql/default.conf
Text conflict in libmysqld/CMakeLists.txt
Text conflict in libmysqld/Makefile.am
Text conflict in mysql-test/collections/default.experimental
Text conflict in mysql-test/extra/rpl_tests/rpl_row_sp006.test
Text conflict in mysql-test/suite/binlog/r/binlog_tmp_table.result
Text conflict in mysql-test/suite/rpl/r/rpl_loaddata.result
Text conflict in mysql-test/suite/rpl/r/rpl_loaddata_fatal.result
Text conflict in mysql-test/suite/rpl/r/rpl_row_create_table.result
Text conflict in mysql-test/suite/rpl/r/rpl_row_sp006_InnoDB.result
Text conflict in mysql-test/suite/rpl/r/rpl_stm_log.result
Text conflict in mysql-test/suite/rpl_ndb/r/rpl_ndb_circular_simplex.result
Text conflict in mysql-test/suite/rpl_ndb/r/rpl_ndb_sp006.result
Text conflict in mysql-test/t/mysqlbinlog.test
Text conflict in sql/CMakeLists.txt
Text conflict in sql/Makefile.am
Text conflict in sql/log_event_old.cc
Text conflict in sql/rpl_rli.cc
Text conflict in sql/slave.cc
Text conflict in sql/sql_binlog.cc
Text conflict in sql/sql_lex.h
21 conflicts encountered.
NOTE
====
mysql-5.1-rpl-merge has been made a mirror of mysql-next-mr:
- "mysql-5.1-rpl-merge$ bzr pull ../mysql-next-mr"
This is the first cset (merge/...) committed after pulling
from mysql-next-mr.
A fix and a test case for Bug#34898 "mysql_info() reports 0 warnings
while mysql_warning_count() reports 1"
Review the patch by Chad Miller, implement review comments
(since Chad left) and push the patch.
This bug is actually not a bug. At least according to Monty.
See Bug#841 "wrong number of warnings" reported back in July 2003
and closed as "not a bug".
mysql_info() was printing the number of truncated columns, not
the number of warnings.
But since the message of mysql_info() was "Warnings: <number of truncated
columns>", people would expect to get the number
of warnings in it, not the number of truncated columns.
So a possible fix would be to change the message of mysql_info()
to say Rows changed: <n>, truncated: <m>.
Instead, put the number of warnings there. That is, remove the
feature that thd->cuted_fields (the number of truncated fields)
is exposed to the client. The number of truncated columns can be
calculated on the client, by analyzing SHOW WARNINGS output,
and in future we may remove thd->cuted_fields altogether.
So let's have one less thing to worry about.
Add an option to control whether the master should keep waiting
until timeout when it detected that there is no semi-sync slave
available.
The bool option 'rpl_semi_sync_master_wait_no_slave' is 1 by
defalt, and will keep waiting until timeout. When set to 0, the
master will switch to asynchronous replication immediately when
no semi-sync slave is available.
Semi-sync status were not reset by FLUSH STATUS, this was because
all semi-sync status variables are defined as SHOW_FUNC and FLUSH
STATUS could only reset SHOW_LONG type variables.
This problem is fixed by change all status variables that should
be reset by FLUSH STATUS from SHOW_FUNC to SHOW_LONG.
After the fix, the following status variables will be reset by
FLUSH STATUS:
Rpl_semi_sync_master_yes_tx
Rpl_semi_sync_master_no_tx
Note: normally, FLUSH STATUS itself will be written into binlog
and be replicated, so after FLUSH STATS, one of
Rpl_semi_sync_master_yes_tx
Rpl_semi_sync_master_no_tx
can be 1 dependent on the semi-sync status. So it's recommended
to use FLUSH NO_WRITE_TO_BINLOG STATUS to avoid this.
Semi-sync uses an extra connection from slave to master to send
replies, this is a normal client connection, and used a normal
SET query to set the reply information on master, which is visible
to user and may cause some confusion and complaining.
This problem is fixed by using the method of sending reply by
using the same connection that is used by master dump thread to
send binlog to slave. Since now the semi-sync plugins are integrated
with the server code, it is not a problem to use the internal net
interfaces to do this.
The master dump thread will mark the event requires a reply and
wait for the reply when the event just sent is the last event
of a transaction and semi-sync status is ON; And the slave will
send a reply to master when it received such an event that requires
a reply.
To-number conversion warnings work differenly with CHAR
and VARCHAR sp variables.
The original revision-IDs are:
staale.smedseng@sun.com-20081124095339-2qdvzkp0rn1ljs30staale.smedseng@sun.com-20081125104611-rtxic5d12e83ag2o
The patch provides ER_TRUNCATED_WRONG_VALUE warning messages
for conversion of VARCHAR to numberic values, in line with
messages provided for CHAR conversions. Conversions are
checked for success, and the message is emitted in case
failure.
The tests are amended to accept the added warning messages,
and explicit conversion of ON/OFF values is added for
statements checking system variables. In test
rpl.rpl_switch_stm_row_mixed checking for warnings is
temporarily disabled for one statement, as this generates
warning messages for strings that vary between executions.
The issue appears when number of heartbeat events non-zero before start of test
block. But really we need to check that no new events has received during test block.
So I did following:
1. Replace absolute values by diff of values
2. Increase heartbeat period from 1.5 to 5 sec
Let
- T be a transactional table and N non-transactional table.
- B be begin, C commit and R rollback.
- N be a statement that accesses and changes only N-tables.
- T be a statement that accesses and changes only T-tables.
In RBR, changes to N-tables that happen early in a transaction are not immediately flushed
upon committing a statement. This behavior may, however, break consistency in the presence
of concurrency since changes done to N-tables become immediately visible to other
connections. To fix this problem, we do the following:
. B N N T C would log - B N C B N C B T C.
. B N N T R would log - B N C B N C B T R.
Note that we are not preserving history from the master as we are introducing a commit that
never happened. However, this seems to be more acceptable than the possibility of breaking
consistency in the presence of concurrency.
CHANGE MASTER TO command required the value for RELAY_LOG_FILE to
be an absolute path, which was different from the requirement of
MASTER_LOG_FILE.
This patch fixed the problem by changing the value for RELAY_LOG_FILE
to be the basename of the log file as that for MASTER_LOG_FILE.
The problem is that there is only one autoinc value associated with
the query when binlogging. If more than one autoinc values are used
in the query, the autoinc values after the first one can be inserted
wrongly on slave. So these autoinc values can become inconsistent on
master and slave.
The problem is resolved by marking all the statements that invoke
a trigger or call a function that updated autoinc fields as unsafe,
and will switch to row-format in Mixed mode. Actually, the statement
is safe if just one autoinc value is used in sub-statement, but it's
impossible to check how many autoinc values are used in sub-statement.)
rpl_slave_skip fails randomly on PB2. This patch fixes the failure by
setting explicit wait for SQL thread to stop, instead of the
wait_for_slave_to_stop mysqltest command, after a start until command
is executed.