We should assume that the store engine will report the first duplicate key for this case.
Old code of suppression of unsafe logging error with LIMIT didn't work, because of wrong usage of my_interval_timer().
Suppress unsafe logging errors to the error log if we get too many unsafe logging errors in a short time.
This is to not overflow the error log with meaningless errors.
- Each error code is suppressed and counted separately.
- We do a 5 minute suppression of new errors if we get more than 10 errors in that time.
Only print unsafe logging errors if log_warnings > 1.
mysql-test/suite/binlog/r/binlog_stm_unsafe_warning.result:
Update test results as INSERT ... ON DUPLICATE KEY UPDATE doesn't get logged anymore
mysql-test/suite/binlog/r/binlog_unsafe.result:
Update test results as INSERT ... ON DUPLICATE KEY UPDATE doesn't get logged anymore
mysql-test/suite/engines/README:
Fixed typos
mysql-test/suite/rpl/r/rpl_known_bugs_detection.result:
Update test results as INSERT ... ON DUPLICATE KEY UPDATE doesn't get logged anymore
sql/sql_base.cc:
Don't log warning if there are two unique keys used with INSERT .. ON DUPLICATE KEY UPDATE.
We should assume that the store engine will report the first duplicate key for this case.
sql/sql_class.cc:
Suppress error in binary log if we get too many unsafe logging errors in a short time.
Only print unsafe logging errors if log_warnings > 1
~40% bugfixed(*) applied
~40$ bugfixed reverted (incorrect or we're not buggy)
~20% bugfixed applied, despite us being not buggy
(*) only changes in the server code, e.g. not cmakefiles
DISCONNECT CON1 AND CON2
Problem:
The test suite/binlog/t/binlog_killed.test makes the connections
con1 and con2 but forgets to disconnect them + wait till that
operation is finished at test end.
This mistake has the potential to harm subsequent tests in
case these tests depend on the content of the processlist.
Solution:
Added disconnect + wait_until_disconnected.inc
within the test cleanup.
WRITTEN WHILE ROWS REMAINS
Problem:
========
When truncate table fails while using transactional based
engines even though the operation errors out we still
continue and log it to binlog. Because of this master has
data but the truncate will be written to binary log which
will cause inconsistency.
Analysis:
========
Truncate table can happen either through drop and create of
table or by deleting rows. In the second case the existing
code is written in such a way that even if an error occurs
the truncate statement will always be binlogged. Which is not
correct.
Binlogging of TRUNCATE TABLE statement should check whether
truncate is executed "transactionally or not". If the table
is transaction based we log the TRUNCATE TABLE only on
successful completion.
If table is non transactional there are possibilities that on
error we could have partial changes done hence in such cases
we do log in spite of errors as some of the lines might have
been removed, so the statement has to be sent to slave.
Fix:
===
Using table handler whether truncate table is being executed
in transaction based mode or not is identified and statement
is binlogged accordingly.
mysql-test/suite/binlog/r/binlog_truncate_kill.result:
Added test case to test the fix for Bug#17942050.
mysql-test/suite/binlog/t/binlog_truncate_kill.test:
Added test case to test the fix for Bug#17942050.
sql/sql_truncate.cc:
Check if truncation is successful or not and retun appropriate
return values so that binlogging can be done based on that.
sql/sql_truncate.h:
Added a new enum.
IN TIME RECOVERY FAILURE ON SLAVES
Problem:
DROP TEMP TABLE IF EXISTS commands can cause point
in time recovery (re-applying binlog) failures.
Analyses:
In RBR, 'DROP TEMPORARY TABLE' commands are
always binlogged by adding 'IF EXISTS' clauses.
Also, the slave SQL thread will not check replicate.* filter
rules for "DROP TEMPORARY TABLE IF EXISTS" queries.
If log-slave-updates is enabled on slave, these queries
will be binlogged in the format of "USE `db`;
DROP TEMPORARY TABLE IF EXISTS `t1`;" irrespective
of filtering rules and irrespective of the `db` existence.
When users try to recover slave from it's own binlog,
use `db` command might fail if `db` is not present on slave.
Fix:
At the time of writing the 'DROP TEMPORARY TABLE
IF EXISTS' query into the binlog, 'use `db`' will not be
present and the table name in the query will be a fully
qualified table name.
Eg:
'USE `db`; DROP TEMPORARY TABLE IF EXISTS `t1`;'
will be logged as
'DROP TEMPORARY TABLE IF EXISTS `db`.`t1`;'.
includes:
* remove some remnants of "Bug#14521864: MYSQL 5.1 TO 5.5 BUGS PARTITIONING"
* introduce LOCK_share, now LOCK_ha_data is strictly for engines
* rea_create_table() always creates .par file (even in "frm-only" mode)
* fix a 5.6 bug, temp file leak on dummy ALTER TABLE
The problem was the Gtid_list event which is logged to the binlog in
10.0 and is not understood by the 5.5 server.
This event is supposed to be replaced with a dummy event for 5.5
servers. But the very first event logged in the very first binlog
has an empty list of GTID, which makes the event too short to be
replacable with an empty event.
The fix is to pad the empty Gtid_list event to be big enough to
be replacable by a dummy event.
BY BINLOG_KILLED_SIMULATE.TEST
'mysqbinlog' tool creates a temporary file while
preparing LOAD DATA QUERY. These files needs to be deleted
at the end of the test script otherwise these files are
left out in the daily-run machines, causing
"no space on device issues"
Fix:
Delete them at the end of these test scripts
1) execute mysqlbinlog with --local-load option to
create these files in a specified tmpdir
2) delete the tmpdir at the end of the test script
MDEV-4489 "Replication of big5, cp932, gbk, sjis strings makes wrong values on slave"
has been fixed.
Problem:
String constants of some Asian charsets (big5,cp932,gbk,sjis)
can have backslash '\' (0x5C) in the second byte of multi-byte characters.
Replicating of such constants using the standard '\'-escaping is dangerous.
Therefore, constants of these charsets are replicated using hex notation:
INSERT INTO t1 (a) VALUES (0x815C);
However, 0xHHHH constants do not work well in some cases,
because they can behave as strings and as numbers, depending on context
(for example, depending on the data type of the column in an INSERT statement).
This SQL script was not replicated correctly with statement-based replication:
SET NAMES gbk;
PREPARE STMT FROM 'INSERT INTO t1 (a) VALUES (?)';
SET @a = '1';
EXECUTE STMT USING @a;
The INSERT statement was replicated as:
INSERT INTO t1 (a) VALUES (0x31);
'1' was correctly converted to the number 1 on master.
But the 0x31 constant was treated as number 49 on slave.
Fix:
1. Binary log now uses X'HHHH' instead of 0xHHHH constants.
2. The X'HHHH' constants now work always as strings, in all contexts.
This is the SQL standard compliant behaviour.
After the fix, the above statement is replicated as:
INSERT INTO t1 (a) VALUES (X'31');
X'31' is treated as string '1' on slave, and is correctly converted to 1.
modified:
@ mysql-test/r/ctype_cp932_binlog_stm.result
@ mysql-test/r/select.result
@ mysql-test/r/select_jcl6.result
@ mysql-test/r/select_pkeycache.result
@ mysql-test/r/user_var-binlog.result
@ mysql-test/r/varbinary.result
@ mysql-test/suite/binlog/r/binlog_stm_ctype_ucs.result
@ mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result
@ mysql-test/suite/rpl/r/rpl_charset_sjis.result
@ mysql-test/suite/rpl/r/rpl_mdev382.result
@ mysql-test/suite/rpl/t/rpl_charset_sjis.test
@ mysql-test/t/ctype_cp932_binlog_stm.test
@ mysql-test/t/select.test
@ mysql-test/t/varbinary.test
Adding and updating tests
@ sql/item.cc
@ sql/item.h
@ sql/sql_yacc.yy
@ sql/sql_lex.cc
Splitting the implementations of X'HH' and 0xHH constants into two
separate classes. Fixing the parser to distinguish the two syntaxes.
@ sql/log_event.cc
Using X'HH' instead of 0xHH for binary logging for string constants
of the "dangerous" charsets.
@ sql/sql_string.h
Adding a helped method String::append_hex().
This makes it clear that the error code has nothing to do with errno.
mysql-test/include/mtr_warnings.sql:
Fixed suppression for new slave error messages
mysql-test/lib/My/Test.pm:
Use 'send' instead of 'print' to avoid errors about "wrong class ... back attempt"
mysql-test/lib/v1/mtr_report.pl:
Fixed suppression for new slave error messages
mysql-test/mysql-test-run.pl:
Fixed suppression for new slave error messages
Removed warning from perl 5.16.2 about arrays
mysql-test/r/flush_read_lock.result:
Fixed suppression for new slave error messages
sql/rpl_reporting.cc:
Instead of writing "Errcode" to the log for Slave errors, use "Internal MariaDB error code"
The slave dump thread running on the master only checked thd->killed whenever
it reached the end of a binlog file, not between events. This could
unnecessarily delay server shutdown.
This was found by code inspection while tracking down some occasional "forcing
close of thread..." errors in Buildbot. Hopefully this will fix the failures,
but the fix is correct in any case.
Also increase the wait during server shutdown, 2 seconds is a bit tight in
case of heavy I/O stall, and it seems better to delay shutdown a bit than
force-kill threads unnecessarily.
Also fix some races in test cases that restart the mysqld server. The .expect
file should be changed with --append_file, --remove_file + --write_file
creates a short window where mysqld can error out due to .expect file missing.
Merge of 10.0-mdev26 feature tree into 10.0-base.
Global transaction ID is prepended to each event group in the binlog.
Slave connect can request to start from GTID position instead of specifying
file name/offset of master binlog. This facilitates easy switch to a new
master.
Slave GTID state is stored in a table mysql.rpl_slave_state, which can be
InnoDB to get crash-safe slave state.
GTID includes a replication domain ID, allowing to keep track of distinct
positions for each of multiple masters.