Description: When the table has more than one unique or primary key,
INSERT... ON DUP KEY UPDATE statement is sensitive to the order in which
the storage engines checks the keys. Depending on this order, the storage
engine may determine different rows to mysql, and hence mysql can update
different rows on master and slave.
Solution: We mark INSERT...ON DUP KEY UPDATE on a table with more than on unique
key as unsafe therefore the event will be logged in row format if it is available
(ROW/MIXED). If only STATEMENT format is available, a warning will be thrown.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Updated result file
mysql-test/suite/binlog/t/binlog_unsafe.test:
Added test to check for warning being thrown when the unsafe statement is executed
mysql-test/suite/rpl/r/rpl_known_bugs_detection.result:
Updated result file
sql/share/errmsg-utf8.txt:
Added new warning message
sql/sql_base.cc:
check for tables in the query with more than one UNIQUE KEY and INSERT ON DUPLICATE KEY UPDATE, and mark such statements unsafe.
mysql-test/suite/innodb/t/group_commit_crash.test:
remove autoincrement to avoid rbr being used for insert ... select
mysql-test/suite/innodb/t/group_commit_crash_no_optimize_thread.test:
remove autoincrement to avoid rbr being used for insert ... select
mysys/my_addr_resolve.c:
a pointer to a buffer is returned to the caller -> the buffer cannot be on the stack
mysys/stacktrace.c:
my_vsnprintf() is ok here, in 5.5
Problem: Statements that write to tables with auto_increment columns
based on the selection from another table, may lead to master
and slave going out of sync, as the order in which the rows
are retrieved from the table may differ on master and slave.
Solution: We mark writing to a table with auto_increment table
based on the rows selected from another table as unsafe. This
will cause the execution of such statements to throw a warning
and forces the statement to be logged in ROW if the logging
format is mixed.
Changes:
1. All the statements that writes to a table with auto_increment
column(s) based on the rows fetched from another table, will now
be unsafe.
2. CREATE TABLE with SELECT will now be unsafe.
sql/share/errmsg-utf8.txt:
Added new warning messages.
sql/sql_base.cc:
-Created function to check statements that write to
tables with auto_increment column and has select.
-Marked all the statements that write to a table
with auto_increment column based on rows fetched
from other table(s) as unsafe.
sql/sql_table.cc:
mark CREATE TABLE[with auto_increment column] as unsafe.
Problem: Statements that write to tables with auto_increment columns
based on the selection from another table, may lead to master
and slave going out of sync, as the order in which the rows
are retrived from the table may differ on master and slave.
Solution: We mark writing to a table with auto_increment table
as unsafe. This will cause the execution of such statements to
throw a warning and forces the statement to be logged in ROW if
the logging format is mixed.
Changes:
1. All the statements that writes to a table with auto_increment
column(s) based on the rows fetched from another table, will now
be unsafe.
2. CREATE TABLE with SELECT will now be unsafe.
sql/share/errmsg-utf8.txt:
Added new Warning messages
sql/sql_base.cc:
created a new function that checks for select + write on a autoinc table
made all such statements to be unsafe.
sql/sql_parse.cc:
made create autoincremnet tabble + select unsafe
Problem: The following statements can cause the slave to go out of sync
if logged in statement format:
INSERT IGNORE...SELECT
INSERT ... SELECT ... ON DUPLICATE KEY UPDATE
REPLACE ... SELECT
UPDATE IGNORE :
CREATE ... IGNORE SELECT
CREATE ... REPLACE SELECT
Background: Since the order of the rows returned by the SELECT
statement or otherwise may differ on master and slave, therefore
the above statements may cuase the salve to go out of sync with
the master.
Fix:
Issue a warning when statements like the above are exectued and
the bin-logging format is statement. If the logging format is mixed,
use row based logging. Marking a statement as unsafe has been
done in the sql/sql_parse.cc instead of sql/sql_yacc.cc, because while
parsing for a token has been done we cannot be sure if the parsing
of the other tokens has been done as well.
Six new warning messages has been added for each unsafe statement.
binlog.binlog_unsafe.test has been updated to incoporate these additional unsafe statments.
******
BUG#11758262 - 50439: MARK INSERT...SEL...ON DUP KEY UPD,REPLACE...SEL,CREATE...[IGN|REPL] SEL
Problem: The following statements can cause the slave to go out of sync
if logged in statement format:
INSERT IGNORE...SELECT
INSERT ... SELECT ... ON DUPLICATE KEY UPDATE
REPLACE ... SELECT
UPDATE IGNORE :
CREATE ... IGNORE SELECT
CREATE ... REPLACE SELECT
Background: Since the order of the rows returned by the SELECT
statement or otherwise may differ on master and slave, therefore
the above statements may cuase the salve to go out of sync with
the master.
Fix:
Issue a warning when statements like the above are exectued and
the bin-logging format is statement. If the logging format is mixed,
use row based logging. Marking a statement as unsafe has been
done in the sql/sql_parse.cc instead of sql/sql_yacc.cc, because while
parsing for a token has been done we cannot be sure if the parsing
of the other tokens has been done as well.
Six new warning messages has been added for each unsafe statement.
binlog.binlog_unsafe.test has been updated to incoporate these additional unsafe statments.
mysql-test/extra/rpl_tests/rpl_insert_duplicate.test:
Test removed: Added the test to rpl.rpl_insert_ignore.test
******
Test removed: the test is redundant as the same is being tested in rpl.rpl_insert_ignore.
mysql-test/extra/rpl_tests/rpl_insert_id.test:
Warnings disabled for the unsafe statements.
mysql-test/extra/rpl_tests/rpl_insert_ignore.test:
1. Disabled warnings while for unsafe statements
2. As INSERT...IGNORE is an unsafe statement, an insert ignore not changing any rows,
will not be logged in the binary log, in the ROW and MIXED modes. It will however be logged
in STATEMENT mode.
mysql-test/r/commit_1innodb.result:
updated result file
******
updated result file
mysql-test/suite/binlog/r/binlog_stm_blackhole.result:
Updated result file.
mysql-test/suite/binlog/r/binlog_unsafe.result:
updated result file
mysql-test/suite/binlog/t/binlog_unsafe.test:
added tests for the statements marked as unsafe.
mysql-test/suite/rpl/r/rpl_insert_duplicate.result:
File Removed :Result file of rpl_insert_duplicate, which has been removed.
mysql-test/suite/rpl/r/rpl_insert_ignore.result:
Added the content of rpl.rpl_insert_duplicate here.
mysql-test/suite/rpl/r/rpl_insert_select.result:
Result file removed as the corresponding test has beenn removed.
mysql-test/suite/rpl/r/rpl_known_bugs_detection.result:
Updated result file.
mysql-test/suite/rpl/t/rpl_insert_duplicate.test:
File Removed: this was a wrapper for rpl.rpl_insert_duplicate.test, which has been removed.
mysql-test/suite/rpl/t/rpl_insert_select.test:
File Removed: This test became redundant after this fix, This test showed how INSERT IGNORE...SELECT break replication, which has been handled in this fix.
mysql-test/suite/rpl/t/rpl_known_bugs_detection.test:
Since all the tests are statement based bugs are being tested, having mixed format
forces the event to be written in row format. When the statement and causes the
test to fail as certain known bugs do not occur when the even is logged in row format.
sql/share/errmsg-utf8.txt:
added 6 new Warning messages.
******
added 6 new Warning messages.
sql/sql_lex.cc:
Added 6 new error Identifier [ER_BINLOG_STMT_UNSAFEE_*]
sql/sql_lex.h:
Added 6 new BINLOG_STMT_UNSAFE_* enums to identify the type of unsafe statement dealt with in this bug.
******
Added 6 new BINLOG_STMT_UNSAFE_* enums to identify the type of unsafe statement dealt with in this bug.
sql/sql_parse.cc:
added check for specific queries and marked them as unsafe.
******
added check for specific queries and marked them as unsafe.
Problem: Warnings for truncated data were generated on hosts with
long host names because @@hostname was inserted into a CHAR(40) column.
Fix: Change CHAR(40) to TEXT.
The lock_type is upgrade to TL_WRITE from TL_WRITE_DELAYED for
INSERT DELAYED when inserting multi values in one statement.
It's safe. But it causes an unsafe warning in SBR.
Make INSERT DELAYED safe by logging it as INSERT without DELAYED.
mysql-test/extra/binlog_tests/binlog_insert_delayed.test:
Updated the test file to test multi INSERT DELAYED statement
is no longer causes an unsafe warning and binlogged as INSERT
without DELAYED.
mysql-test/extra/rpl_tests/create_recursive_construct.inc:
Updated for the patch of bug#54579.
mysql-test/suite/binlog/r/binlog_row_binlog.result:
Updated for the patch of bug#54579.
mysql-test/suite/binlog/r/binlog_statement_insert_delayed.result:
Test result for BUG#54579.
mysql-test/suite/binlog/r/binlog_stm_binlog.result:
Updated for the patch of bug#54579.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Updated for the patch of bug#54579.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Updated for the patch of bug#54579.
sql/sql_insert.cc:
Added code to genetate a new query string for removing
DELAYED keyword for multi INSERT DEALAYED statement.
sql/sql_yacc.yy:
Added code to record the DELAYED keyword position and remove the setting
of unsafe statement for INSERT DELAYED statement
After BUG#36649, warnings for sub-statements are cleared when a
new sub-statement is started. This is problematic since it suppresses
warnings for unsafe statements in some cases. It is important that we
always give a warning to the client, because the user needs to know
when there is a risk that the slave goes out of sync.
We fixed the problem by generating warning messages for unsafe statements
while returning from a stored procedure, function, trigger or while
executing a top level statement.
We also started checking unsafeness when both performance and log tables are
used. This is necessary after the performance schema which does a distinction
between performance and log tables.
mysql-test/extra/rpl_tests/create_recursive_construct.inc:
Changed the order of the calls in the procedure because the code
that checks if a warning message is printed out expects that the
first statement gives an warning what is not the case for INSERT
INTO ta$CRC_ARG_level VALUES (47);
mysql-test/suite/binlog/r/binlog_stm_unsafe_warning.result:
Updated the result file.
mysql-test/suite/binlog/r/binlog_unsafe.result:
There are several changes here:
(1) - Changed the CREATE PROCEDURE $CRC.
(2) - The procedure $CRC was failing and the content of the binlog
was being printed out, after fix (1) the failure disappeared.
(3) - The warning message for unsafeness due to auto-increment collumns was
changed.
(4) - The warning message for unsafeness due to VERSION(), RAND() was changed.
mysql-test/suite/binlog/t/binlog_stm_unsafe_warning.test:
Tested filters.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Reenabled the test case binlog_unsafe.
mysql-test/suite/binlog/t/disabled.def:
Reenabled the test case binlog_unsafe.
mysql-test/suite/rpl/r/rpl_begin_commit_rollback.result:
Updated the result file.
mysql-test/suite/rpl/r/rpl_non_direct_stm_mixing_engines.result:
Updated the result file.
mysql-test/suite/rpl/r/rpl_stm_auto_increment_bug33029.result:
Updated the result file.
sql/sql_class.cc:
Moved the stmt_accessed_table_flag variable and related information to the
LEX as we need the variable reset after each statement even inside a stored
procedure, what did not happen if the information was in the THD.
Changed the routine in the THD::binlog_query that prints the warning
messages to avoid trying to print them when inside a stored procedure,
function or trigger.
Checked for unsafeness when both performance and log tables where used.
After the introduction of the performance schema, we need to check both.
On Unix systems TZ can be set to change the time zone for specific processes only.
But on Windows this does not fully work. It changes some aspects of time zones
in the system but not others (notably localtime() vs. file system time stamps).
This causes test failures in Windows in certain time zones (but not all),
where PURGE BEFORE DATE statements get the wrong files when TZ is set to
+03:00 by default.
Fix by only setting TZ in the small number of tests that really need it, and leave
it untouched in the rest.
Thanks to Alex Budovski for helping with this.
mysql-test/include/ps_conv.inc:
Explicitly set TIME_ZONE, as mysql-test-run.pl now does not set it.
mysql-test/mysql-test-run.pl:
Do not set TZ by default, as it causes problems on Windows.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Explicitly set TIME_ZONE, as mysql-test-run.pl now does not set it.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Explicitly set TIME_ZONE, as mysql-test-run.pl now does not set it.
mysql-test/suite/rpl/r/rpl_mixed_ddl_dml.result:
Explicitly set TIME_ZONE, as mysql-test-run.pl now does not set it.
mysql-test/suite/rpl/t/rpl_mixed_ddl_dml.test:
Explicitly set TIME_ZONE, as mysql-test-run.pl now does not set it.
mysql-test/t/mysqlbinlog2-master.opt:
mysql-test-run.pl no longer sets TZ by default, so set it explicitly for this particular test.
Problem: When RAND() is binlogged in statement mode, the seed is
binlogged too, so the replication slave generates the same
sequence of random numbers. This makes replication work in many
cases, but not in all cases: the order of rows is not guaranteed
for, e.g., UPDATE or INSERT...SELECT statements, so the row data
will be different if master and slave retrieve the rows in
different orders.
Fix: Mark RAND() as unsafe. It will generate a warning if
binlog_format=STATEMENT and switch to row-logging if
binlog_format=ROW.
mysql-test/extra/rpl_tests/rpl_row_func003.test:
updated test case to ignore new warnings
mysql-test/suite/binlog/r/binlog_unsafe.result:
updated result file
mysql-test/suite/binlog/t/binlog_unsafe.test:
Added test for RAND().
Also clarified some old comments.
mysql-test/suite/rpl/r/rpl_misc_functions.result:
updated result file
mysql-test/suite/rpl/r/rpl_nondeterministic_functions.result:
updated test case to ignore new warnings
mysql-test/suite/rpl/r/rpl_optimize.result:
updated result file
mysql-test/suite/rpl/r/rpl_row_func003.result:
updated result file
mysql-test/suite/rpl/t/rpl_misc_functions.test:
updated test case to ignore new warnings
mysql-test/suite/rpl/t/rpl_nondeterministic_functions.test:
updated test case to ignore new warnings
mysql-test/suite/rpl/t/rpl_optimize.test:
updated test case to ignore new warnings
mysql-test/suite/rpl/t/rpl_trigger.test:
updated test case to ignore new warnings
mysql-test/suite/rpl_ndb/r/rpl_ndb_func003.result:
updated result file
sql/item_create.cc:
Mark RAND() unsafe.
Conflicts:
Text conflict in .bzr-mysql/default.conf
Text conflict in mysql-test/extra/rpl_tests/rpl_loaddata.test
Text conflict in mysql-test/r/mysqlbinlog2.result
Text conflict in mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result
Text conflict in mysql-test/suite/binlog/r/binlog_unsafe.result
Text conflict in mysql-test/suite/rpl/r/rpl_insert_id.result
Text conflict in mysql-test/suite/rpl/r/rpl_loaddata.result
Text conflict in mysql-test/suite/rpl/r/rpl_stm_auto_increment_bug33029.result
Text conflict in mysql-test/suite/rpl/r/rpl_udf.result
Text conflict in mysql-test/suite/rpl/t/rpl_slow_query_log.test
Text conflict in sql/field.h
Text conflict in sql/log.cc
Text conflict in sql/log_event.cc
Text conflict in sql/log_event_old.cc
Text conflict in sql/mysql_priv.h
Text conflict in sql/share/errmsg.txt
Text conflict in sql/sp.cc
Text conflict in sql/sql_acl.cc
Text conflict in sql/sql_base.cc
Text conflict in sql/sql_class.h
Text conflict in sql/sql_db.cc
Text conflict in sql/sql_delete.cc
Text conflict in sql/sql_insert.cc
Text conflict in sql/sql_lex.cc
Text conflict in sql/sql_lex.h
Text conflict in sql/sql_load.cc
Text conflict in sql/sql_table.cc
Text conflict in sql/sql_update.cc
Text conflict in sql/sql_view.cc
Conflict adding files to storage/innobase. Created directory.
Conflict because storage/innobase is not versioned, but has versioned children. Versioned directory.
Conflict adding file storage/innobase. Moved existing file to storage/innobase.moved.
Conflict adding files to storage/innobase/handler. Created directory.
Conflict because storage/innobase/handler is not versioned, but has versioned children. Versioned directory.
Contents conflict in storage/innobase/handler/ha_innodb.cc
Problem: The test was written before BUG#45827 was fixed.
The test contained code that assumed the wrong behavior,
pre-BUG#45827. Then, the fix for BUG#45827 was merged
from 5.1-rep+2 to 5.1-rep+3. Since the test case assumed
the wrong behavior, it failed. This should have been fixed
by making the test assume the correct behavior, but was
fixed by updating the result file to assert failure.
Fix 1: fix the test to assume correct behavior
(post-BUG#45827), update result file.
Fix 2: make test fail with 'die' instead of 'exit' when
wrong behavior is detected. Thus, the test cannot be
silenced with a wrong result file in case the behavior
will change again.
mysql-test/extra/rpl_tests/create_recursive_construct.inc:
Replaced 'exit' by 'die' to avoid similar
mysql-test/suite/binlog/r/binlog_unsafe.result:
Updated result file.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Since BUG#45827 is now fixed, we need to update the test case
in two places where it expects the wrong result because of
BUG#45827.
Problem: Some system functions that could return different values on
master and slave were not marked unsafe. In particular:
GET_LOCK
IS_FREE_LOCK
IS_USED_LOCK
MASTER_POS_WAIT
RELEASE_LOCK
SLEEP
SYSDATE
VERSION
Fix: Mark these functions unsafe.
mysql-test/extra/rpl_tests/rpl_stm_000001.test:
- The test does not work in mixed mode any more, since it tries to
simulate an error in the sql thread in a query that uses get_lock.
Since get_lock now causes the query to be logged in row format,
the error didn't happen. Hence, we now force statement mode.
- Warnings must be disabled when the unsafe query is issued.
- Replaced some save_master_pos+connection slave+sync_with_master
by sync_slave_with_master.
mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result:
updated result file
mysql-test/suite/binlog/r/binlog_stm_row.result:
updated result file
mysql-test/suite/binlog/r/binlog_unsafe.result:
updated result file
mysql-test/suite/binlog/t/binlog_killed.test:
binlog_killed only works in statement format now, since
it switches to row mode in mixed mode.
mysql-test/suite/binlog/t/binlog_stm_mix_innodb_myisam.test:
suppress warnings for unsafe statements
mysql-test/suite/binlog/t/binlog_stm_row.test:
- Suppress warnings in test that causes warnings.
- The test sets binlog format explicitly, so no need to execute it
twice.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Added test for all unsafe system functions. This test also includes
system functions that were unsafe prior to BUG#47995.
mysql-test/suite/rpl/r/rpl_err_ignoredtable.result:
updated result file
mysql-test/suite/rpl/r/rpl_get_lock.result:
updated result file
mysql-test/suite/rpl/r/rpl_nondeterministic_functions.result:
new result file
mysql-test/suite/rpl/r/rpl_stm_000001.result:
updated result file
mysql-test/suite/rpl/r/rpl_trigger.result:
updated result file
mysql-test/suite/rpl/t/rpl_err_ignoredtable.test:
- suppress warnings for unsafe statement
- replaced save_master_pos+connection slave+sync_with_master
with sync_slave_with_master
mysql-test/suite/rpl/t/rpl_get_lock.test:
update test case that causes new warnings
mysql-test/suite/rpl/t/rpl_nondeterministic_functions.test:
Added new test case for nondeterministic functions.
mysql-test/suite/rpl/t/rpl_trigger.test:
update test case that causes new warnings
sql/item_create.cc:
Marked some system functions unsafe.
sql/item_strfunc.cc:
Clarified comment related to this bug.
sql/sql_yacc.yy:
Marked sysdate unsafe.
After fix of bug46322, logging to table is turned off, each test
that need this should turn on it in it's opt file.
Add suppression to unsafe statement warnings for binlog_unsafe.test.
mysql-test/suite/binlog/t/binlog_unsafe-master.opt:
After fix of bug46322, logging to table is turned off, each test that need this should turn on it in it's opt file.
mysql-test/suite/binlog/t/binlog_unsafe.test:
suppress Unsafe statement warnings
One statement that have more than one different tables to update with
autoinc columns just was marked as unsafe in mixed mode, so the unsafe
warning can't be produced in statement mode.
To fix the problem, mark the statement as unsafe in statement mode too.
mysql-test/extra/rpl_tests/rpl_insert_id.test:
The test case is updated due to the patch of bug#45827.
mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result:
The test result is updated due to the patch of bug#45827.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Test result for bug#45827.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Added test to verify if stmt that have more than one
different tables to update with autoinc columns will
produce unsafe warning
mysql-test/suite/rpl/r/rpl_stm_auto_increment_bug33029.result:
The test result is updated due to the patch of bug#45827.
mysql-test/suite/rpl/t/rpl_trigger.test:
The test case is updated due to the patch of bug#45827.
mysql-test/suite/rpl/t/rpl_variables_stm.test:
The test case is updated due to the patch of bug#45827.
sql/sql_base.cc:
Reomved the 'set_current_stmt_binlog_row_based_if_mixed' function
for producing unsafe warnings by executing 'decide_logging_format'
function later in statement mode
This is a post-push fix addressing review requests and
problems with extra warnings.
Problem 1: The sub-statement where an unsafe warning was detected was
printed as part of the warning. This was ok for statements that
were unsafe due to, e.g., calls to UUID(), but did not make
sense for statements that were unsafe because there was more than
one autoincrement column (unsafeness in this case comes from the
combination of several sub-statements).
Fix 1: Instead of printing the sub-statement, print an explanation
of why the statement is unsafe.
Problem 2:
When a recursive construct (i.e., stored proceure, stored
function, trigger, view, prepared statement) contained several
sub-statements, and at least one of them was unsafe, there would be
one unsafeness warning per sub-statement - even for safe
sub-statements.
Fix 2:
Ensure that each type of warning is printed at most once, by
remembering throughout the execution of the statement which types
of warnings have been printed.
mysql-test/extra/rpl_tests/create_recursive_construct.inc:
- Clarified comment per review request.
- Added checks for the number of warnings in each invocation.
mysql-test/extra/rpl_tests/rpl_insert_delayed.test:
Per review request, replaced @@session.binlog_format by
@@global.binlog_format, since INSERT DELAYED reads the global
variable. (In this test case, the two variables have the same
value, so the change is cosmetic.)
mysql-test/r/sp_trans.result:
updated result file
mysql-test/suite/binlog/r/binlog_statement_insert_delayed.result:
updated result file
mysql-test/suite/binlog/r/binlog_stm_ps.result:
updated result file
mysql-test/suite/binlog/r/binlog_stm_unsafe_warning.result:
updated result file
mysql-test/suite/binlog/r/binlog_unsafe.result:
Updated result file. Note that duplicate warnings are now gone.
mysql-test/suite/binlog/t/binlog_unsafe.test:
- Added tests for: (1) a statement that is unsafe in many ways;
(2) a statement that is unsafe in the same way several times.
- Use -- style to invoke mysqltest commands.
mysql-test/suite/rpl/r/rpl_stm_found_rows.result:
updated result file
mysql-test/suite/rpl/r/rpl_stm_loadfile.result:
updated result file
mysql-test/suite/rpl/t/rpl_mix_found_rows.test:
Per review request, added comment explaining what the test case
does (copied from rpl_stm_found_rows.test)
mysql-test/suite/rpl/t/rpl_stm_found_rows.test:
Clarified grammar in comment.
mysql-test/suite/rpl_ndb/r/rpl_ndb_binlog_format_errors.result:
Updated result file.
sql/item_create.cc:
Made set_stmt_unsafe take one parameter, describing the
type of unsafeness.
sql/sp_head.cc:
Added unsafe_flags field and made it hold all the unsafe flags.
sql/sp_head.h:
- Removed the BINLOG_ROW_BASED_IF_MIXED flag from m_flags.
Instead, we use the new unsafe_flags field to hold the
unsafeness state of the sp.
- Made propagate_attributes() copy all unsafe flags.
sql/sql_base.cc:
- Made LEX::set_stmt_unsafe() take an extra argument.
- Made binlog_unsafe_warning_flags store the type of unsafeness.
- Per review requests, clarified comments
- Added DBUG printouts
sql/sql_class.cc:
- Made warnings be generated in issue_warnings() and call that from
binlog_query(). Wrote issue_warnings(), which prints zero or more
warnings, avoiding to print warnings more than once per statement.
- Per review request, added @todo so that we remember to assert
correct behavior in binlog_query.
sql/sql_class.h:
- Removed BINLOG_WARNING_PRINTED
- Use [set|clear]_current_stmt_binlog_row_based() instead of
modifying the flag directly.
- added issue_unsafe_warnings() (only called from binlog_unsafe)
- Per review request, improved some documentation.
sql/sql_insert.cc:
Added extra argument to LEX::set_stmt_unsafe()
sql/sql_lex.h:
- Added enum_binlog_stmt_unsafe, listing all types of unsafe
statements.
- Per review requests, improved many comments for member
functions.
- Added [get|set]_stmt_unsafe_flags(), which return/set all the
unsafe flags for a statement.
sql/sql_parse.cc:
- Renamed binlog_warning_flags to binlog_unsafe_warning_flags.
- Per review requests, improved comment.
sql/sql_view.cc:
Made views propagate all the new unsafe flags.
sql/sql_yacc.yy:
Added parameter to set_stmt_unsafe().
storage/innobase/handler/ha_innodb.cc:
Per review requests, replaced DBUG_EXECUTE_IF() by DBUG_EVALUATE_IF().
mysql-test/r/partition_innodb_stmt.result:
Error message changed.
mysql-test/r/sp_trans.result:
Error message changed.
mysql-test/suite/binlog/r/binlog_stm_unsafe_warning.result:
Error message changed.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Test now uses udf's, so needs to source include/have_udf.inc
mysql-test/suite/parts/r/rpl_partition.result:
updated result file
mysql-test/suite/parts/t/rpl_partition.test:
We no longer allow a slave that has binlog_format=statement
to execute row events. Hence we force the slave to have
binlog_format=row.
mysql-test/suite/rpl_ndb/t/rpl_ndb_binlog_format_errors.test:
The test uses the example plugin, hence it must
source include/have_example_plugin.inc.
General overview:
The logic for switching to row format when binlog_format=MIXED had
numerous flaws. The underlying problem was the lack of a consistent
architecture.
General purpose of this changeset:
This changeset introduces an architecture for switching to row format
when binlog_format=MIXED. It enforces the architecture where it has
to. It leaves some bugs to be fixed later. It adds extensive tests to
verify that unsafe statements work as expected and that appropriate
errors are produced by problems with the selection of binlog format.
It was not practical to split this into smaller pieces of work.
Problem 1:
To determine the logging mode, the code has to take several parameters
into account (namely: (1) the value of binlog_format; (2) the
capabilities of the engines; (3) the type of the current statement:
normal, unsafe, or row injection). These parameters may conflict in
several ways, namely:
- binlog_format=STATEMENT for a row injection
- binlog_format=STATEMENT for an unsafe statement
- binlog_format=STATEMENT for an engine only supporting row logging
- binlog_format=ROW for an engine only supporting statement logging
- statement is unsafe and engine does not support row logging
- row injection in a table that does not support statement logging
- statement modifies one table that does not support row logging and
one that does not support statement logging
Several of these conflicts were not detected, or were detected with
an inappropriate error message. The problem of BUG#39934 was that no
appropriate error message was written for the case when an engine
only supporting row logging executed a row injection with
binlog_format=ROW. However, all above cases must be handled.
Fix 1:
Introduce new error codes (sql/share/errmsg.txt). Ensure that all
conditions are detected and handled in decide_logging_format()
Problem 2:
The binlog format shall be determined once per statement, in
decide_logging_format(). It shall not be changed before or after that.
Before decide_logging_format() is called, all information necessary to
determine the logging format must be available. This principle ensures
that all unsafe statements are handled in a consistent way.
However, this principle is not followed:
thd->set_current_stmt_binlog_row_based_if_mixed() is called in several
places, including from code executing UPDATE..LIMIT,
INSERT..SELECT..LIMIT, DELETE..LIMIT, INSERT DELAYED, and
SET @@binlog_format. After Problem 1 was fixed, that caused
inconsistencies where these unsafe statements would not print the
appropriate warnings or errors for some of the conflicts.
Fix 2:
Remove calls to THD::set_current_stmt_binlog_row_based_if_mixed() from
code executed after decide_logging_format(). Compensate by calling the
set_current_stmt_unsafe() at parse time. This way, all unsafe statements
are detected by decide_logging_format().
Problem 3:
INSERT DELAYED is not unsafe: it is logged in statement format even if
binlog_format=MIXED, and no warning is printed even if
binlog_format=STATEMENT. This is BUG#45825.
Fix 3:
Made INSERT DELAYED set itself to unsafe at parse time. This allows
decide_logging_format() to detect that a warning should be printed or
the binlog_format changed.
Problem 4:
LIMIT clause were not marked as unsafe when executed inside stored
functions/triggers/views/prepared statements. This is
BUG#45785.
Fix 4:
Make statements containing the LIMIT clause marked as unsafe at
parse time, instead of at execution time. This allows propagating
unsafe-ness to the view.
mysql-test/extra/rpl_tests/create_recursive_construct.inc:
Added auxiliary file used by binlog_unsafe.test to create and
execute recursive constructs
(functions/procedures/triggers/views/prepared statements).
mysql-test/extra/rpl_tests/rpl_foreign_key.test:
removed unnecessary set @@session.binlog_format
mysql-test/extra/rpl_tests/rpl_insert_delayed.test:
Filter out table id from table map events in binlog listing.
Got rid of $binlog_format_statement.
mysql-test/extra/rpl_tests/rpl_ndb_apply_status.test:
disable warnings around call to unsafe procedure
mysql-test/include/rpl_udf.inc:
Disabled warnings for code that generates warnings
for some binlog formats. That would otherwise cause
inconsistencies in the result file.
mysql-test/r/mysqldump.result:
Views are now unsafe if they contain a LIMIT clause.
That fixed BUG#45831. Due to BUG#45832, a warning is
printed for the CREATE VIEW statement.
mysql-test/r/sp_trans.result:
Unsafe statements in stored procedures did not give a warning if
binlog_format=statement. This is BUG#45824. Now they do, so this
result file gets a new warning.
mysql-test/suite/binlog/r/binlog_multi_engine.result:
Error message changed.
mysql-test/suite/binlog/r/binlog_statement_insert_delayed.result:
INSERT DELAYED didn't generate a warning when binlog_format=STATEMENT.
That was BUG#45825. Now there is a warning, so result file needs to be
updated.
mysql-test/suite/binlog/r/binlog_stm_ps.result:
Changed error message.
mysql-test/suite/binlog/r/binlog_unsafe.result:
updated result file:
- error message changed
- added test for most combinations of unsafe constructs invoked
from recursive constructs
- INSERT DELAYED now gives a warning (because BUG#45826 is fixed)
- INSERT..SELECT..LIMIT now gives a warning from inside recursive
constructs (because BUG#45785 was fixed)
- When a recursive construct (e.g., stored proc or function)
contains more than one statement, at least one of which is
unsafe, then all statements in the recursive construct give
warnings. This is a new bug introduced by this changeset.
It will be addressed in a post-push fix.
mysql-test/suite/binlog/t/binlog_innodb.test:
Changed error code for innodb updates with READ COMMITTED or
READ UNCOMMITTED transaction isolation level and
binlog_format=statement.
mysql-test/suite/binlog/t/binlog_multi_engine.test:
The error code has changed for statements where more than one
engine is involved and one of them is self-logging.
mysql-test/suite/binlog/t/binlog_unsafe-master.opt:
Since binlog_unsafe now tests unsafe-ness of UDF's, we need an extra
flag in the .opt file.
mysql-test/suite/binlog/t/binlog_unsafe.test:
- Clarified comment.
- Rewrote first part of test. Now it tests not only unsafe variables
and functions, but also unsafe-ness due to INSERT..SELECT..LIMIT,
INSERT DELAYED, insert into two autoinc columns, use of UDF's, and
access to log tables in the mysql database.
Also, in addition to functions, procedures, triggers, and prepared
statements, it now also tests views; and it constructs recursive
calls in two levels by combining these recursive constructs.
Part of the logic is in extra/rpl_tests/create_recursive_construct.inc.
- added tests for all special system variables that should not be unsafe.
- added specific tests for BUG#45785 and BUG#45825
mysql-test/suite/rpl/r/rpl_events.result:
updated result file
mysql-test/suite/rpl/r/rpl_extraColmaster_innodb.result:
updated result file
mysql-test/suite/rpl/r/rpl_extraColmaster_myisam.result:
updated result file
mysql-test/suite/rpl/r/rpl_foreign_key_innodb.result:
updated result file
mysql-test/suite/rpl/r/rpl_idempotency.result:
updated result file
mysql-test/suite/rpl/r/rpl_mix_found_rows.result:
Split rpl_found_rows.test into rpl_mix_found_rows.test (a new file) and
rpl_stm_found_rows.test (renamed rpl_found_rows.test). This file equals
the second half of the old rpl_found_rows.result, with the following
modifications:
- minor formatting changes
- additional initialization
mysql-test/suite/rpl/r/rpl_mix_insert_delayed.result:
Moved out code operating in mixed mode from rpl_stm_insert_delayed
(into rpl_mix_insert_delayed) and got rid of explicit setting of
binlog format.
mysql-test/suite/rpl/r/rpl_rbr_to_sbr.result:
updated result file
mysql-test/suite/rpl/r/rpl_row_idempotency.result:
Moved the second half of rpl_idempotency.test, which only
executed in row mode, to rpl_row_idempotency.test. This is
the new result file.
mysql-test/suite/rpl/r/rpl_row_insert_delayed.result:
Got rid of unnecessary explicit setting of binlog format.
mysql-test/suite/rpl/r/rpl_stm_found_rows.result:
Split rpl_found_rows.test into rpl_mix_found_rows.test (a new file) and
rpl_stm_found_rows.test (renamed rpl_found_rows.test). Changes in
this file:
- minor formatting changes
- warning is now issued for unsafe statements inside procedures
(since BUG#45824 is fixed)
- second half of file is moved to rpl_mix_found_rows.result
mysql-test/suite/rpl/r/rpl_stm_insert_delayed.result:
Moved out code operating in mixed mode from rpl_stm_insert_delayed
(into rpl_mix_insert_delayed) and got rid of explicit setting of
binlog format.
mysql-test/suite/rpl/r/rpl_stm_loadfile.result:
error message changed
mysql-test/suite/rpl/r/rpl_temporary_errors.result:
updated result file
mysql-test/suite/rpl/r/rpl_udf.result:
Remove explicit set of binlog format (and triplicate test execution)
and rely on test system executing the test in all binlog formats.
mysql-test/suite/rpl/t/rpl_bug31076.test:
Test is only valid in mixed or row mode since it generates row events.
mysql-test/suite/rpl/t/rpl_events.test:
Removed explicit set of binlog_format and removed duplicate testing.
Instead, we rely on the test system to try all binlog formats.
mysql-test/suite/rpl/t/rpl_extraColmaster_innodb.test:
Removed triplicate testing and instead relying on test system.
Test is only relevant for row format since statement-based replication
cannot handle extra columns on master.
mysql-test/suite/rpl/t/rpl_extraColmaster_myisam.test:
Removed triplicate testing and instead relying on test system.
Test is only relevant for row format since statement-based replication
cannot handle extra columns on master.
mysql-test/suite/rpl/t/rpl_idempotency-slave.opt:
Removed .opt file to avoid server restarts.
mysql-test/suite/rpl/t/rpl_idempotency.test:
- Moved out row-only tests to a new test file, rpl_row_idempotency.test.
rpl_idempotency now only contains tests that execute in all
binlog_formats.
- While I was here, also removed .opt file to avoid server restarts.
The slave_exec_mode is now set inside the test instead.
mysql-test/suite/rpl/t/rpl_mix_found_rows.test:
Split rpl_found_rows.test into rpl_mix_found_rows.test (a new file) and
rpl_stm_found_rows.test (renamed rpl_found_rows.test). This file
contains the second half of the original rpl_found_rows.test with the
follwing changes:
- initialization
- removed SET_BINLOG_FORMAT and added have_binlog_format_mixed.inc
- minor formatting changes
mysql-test/suite/rpl/t/rpl_mix_insert_delayed.test:
Moved out code operating in mixed mode from rpl_stm_insert_delayed
(into rpl_mix_insert_delayed) and got rid of explicit setting of
binlog format.
mysql-test/suite/rpl/t/rpl_rbr_to_sbr.test:
Test cannot execute in statement mode, since we no longer
switch to row format when binlog_format=statement.
Enforced mixed mode throughout the test.
mysql-test/suite/rpl/t/rpl_row_idempotency.test:
Moved the second half of rpl_idempotency.test, which only
executed in row mode, to this new file. We now rely on the
test system to set binlog format.
mysql-test/suite/rpl/t/rpl_row_insert_delayed.test:
- Got rid of unnecessary explicit setting of binlog format.
- extra/rpl_tests/rpl_insert_delayed.test does not need the
$binlog_format_statement variable any more, so that was
removed.
mysql-test/suite/rpl/t/rpl_slave_skip.test:
The test switches binlog_format internally and master generates both
row and statement events. Hence, the slave must be able to log in both
statement and row format. Hence test was changed to only execute in
mixed mode.
mysql-test/suite/rpl/t/rpl_stm_found_rows.test:
Split rpl_found_rows.test into rpl_mix_found_rows.test (a new file) and
rpl_stm_found_rows.test (renamed rpl_found_rows.test). Changes in
this file:
- minor formatting changes
- added have_binlog_format_statement and removed SET BINLOG_FORMAT.
- second half of file is moved to rpl_mix_found_rows.test
- added cleanup code
mysql-test/suite/rpl/t/rpl_stm_insert_delayed.test:
Moved out code operating in mixed mode from rpl_stm_insert_delayed
(into rpl_mix_insert_delayed) and got rid of explicit setting of
binlog format.
mysql-test/suite/rpl/t/rpl_switch_stm_row_mixed.test:
The test switches binlog_format internally and master generates both
row and statement events. Hence, the slave must be able to log in both
statement and row format. Hence test was changed to only execute in
mixed mode on slave.
mysql-test/suite/rpl/t/rpl_temporary_errors.test:
Removed explicit set of binlog format. Instead, the test now only
executes in row mode.
mysql-test/suite/rpl/t/rpl_udf.test:
Remove explicit set of binlog format (and triplicate test execution)
and rely on test system executing the test in all binlog formats.
mysql-test/suite/rpl_ndb/combinations:
Added combinations file for rpl_ndb.
mysql-test/suite/rpl_ndb/r/rpl_ndb_binlog_format_errors.result:
new result file
mysql-test/suite/rpl_ndb/r/rpl_ndb_circular_simplex.result:
updated result file
mysql-test/suite/rpl_ndb/t/rpl_ndb_2innodb.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_2myisam.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_basic.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_binlog_format_errors-master.opt:
new option file
mysql-test/suite/rpl_ndb/t/rpl_ndb_binlog_format_errors-slave.opt:
new option file
mysql-test/suite/rpl_ndb/t/rpl_ndb_binlog_format_errors.test:
New test case to verify all errors and warnings generated by
decide_logging_format.
mysql-test/suite/rpl_ndb/t/rpl_ndb_blob.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_blob2.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_circular.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_circular_simplex.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
While I was here, also made the test clean up after itself.
mysql-test/suite/rpl_ndb/t/rpl_ndb_commit_afterflush.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_ctype_ucs2_def.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_delete_nowhere.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_do_db.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_do_table.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_func003.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_innodb_trans.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_insert_ignore.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_mixed_engines_transactions.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_multi_update3.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_rep_ignore.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_row_001.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_sp003.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_sp006.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/suite/rpl_ndb/t/rpl_ndb_trig004.test:
The test needs slave to be able to switch to row mode, so the
test was changed to only execute in mixed and row mode.
mysql-test/t/partition_innodb_stmt.test:
Changed error code for innodb updates with READ COMMITTED or
READ UNCOMMITTED transaction isolation level and
binlog_format=statement.
sql/event_db_repository.cc:
Use member function to read current_stmt_binlog_row_based.
sql/events.cc:
Use member function to read current_stmt_binlog_row_based.
sql/ha_ndbcluster_binlog.cc:
reset_current_stmt_binlog_row_based() is not a no-op for the ndb_binlog
thread any more. Instead, the ndb_binlog thread now forces row mode both
initially and just after calling mysql_parse. (mysql_parse() is the only
place where reset_current_stmt_binlog_row_based() may be called from
the ndb_binlog thread, so these are the only two places that need to
change.)
sql/ha_partition.cc:
Use member function to read current_stmt_binlog_row_based.
sql/handler.cc:
Use member function to read current_stmt_binlog_row_based.
sql/item_create.cc:
Added DBUG_ENTER to some functions, to be able to trace when
set_stmt_unsafe is called.
sql/log.cc:
Use member function to read current_stmt_binlog_row_based.
sql/log_event.cc:
- Moved logic for changing to row format out of do_apply_event (and into
decide_logging_format).
- Added @todo comment for post-push cleanup.
sql/log_event_old.cc:
Move logic for changing to row format out of do_apply_event (and into
decide_logging_format).
sql/mysql_priv.h:
Make decide_logging_format() a member of the THD class, for two reasons:
- It is natural from an object-oriented perspective.
- decide_logging_format() needs to access private members of THD
(specifically, the new binlog_warning_flags field).
sql/rpl_injector.cc:
Removed call to set_current_stmt_binlog_row_based().
From now on, only decide_logging_fromat is allowed to modify
current_stmt_binlog_row_based. This call is from the ndb_binlog
thread, mostly executing code in ha_ndbcluster_binlog.cc.
This call can be safely removed, because:
- current_stmt_binlog_row_based is initialized for the ndb_binlog
thread's THD object when the THD object is created. So we're
not going to read uninitialized memory.
- The behavior of ndb_binlog thread does not use the state of the
current_stmt_binlog_row_based. It is conceivable that the
ndb_binlog thread would rely on the current_stmt_binlog_format
in two situations:
(1) when it calls mysql_parse;
(2) when it calls THD::binlog_query.
In case (1), it always clears THD::options&OPTION_BIN_LOG (because
run_query() in ha_ndbcluster_binlog.cc is only called with
disable_binlogging = TRUE).
In case (2), it always uses qtype=STMT_QUERY_TYPE.
sql/set_var.cc:
Added @todo comment for post-push cleanup.
sql/share/errmsg.txt:
Added new error messages and clarified ER_BINLOG_UNSAFE_STATEMENT.
sql/sp.cc:
Added DBUG_ENTER, to be able to trace when set_stmt_unsafe is called.
Got rid of MYSQL_QUERY_TYPE: it was equivalent to STMT_QUERY_TYPE.
sql/sp_head.cc:
Use member function to read current_stmt_binlog_row_based.
sql/sp_head.h:
Added DBUG_ENTER, to be able to trace when set_stmt_unsafe is called.
sql/sql_acl.cc:
Got rid of MYSQL_QUERY_TYPE: it was equivalent to STMT_QUERY_TYPE.
sql/sql_base.cc:
- Made decide_logging_format take care of all logic for deciding the
logging format, and for determining the related warnings and errors.
See comment above decide_logging_format for details.
- Made decide_logging_format a member function of THD, since it needs
to access private members of THD and since its purpose is to update
the state of a THD object.
- Added DBUG_ENTER, to be able to trace when set_stmt_unsafe is called.
sql/sql_class.cc:
- Moved logic for determining unsafe warnings away from THD::binlog_query
(and into decide_logging_format()). Now, it works like this:
1. decide_logging_format detects that the current statement shall
produce a warning, if it ever makes it to the binlog
2. decide_logging_format sets a flag of THD::binlog_warning_flags.
3. THD::binlog_query reads the flag. If the flag is set, it generates
a warning.
- Use member function to read current_stmt_binlog_row_based.
sql/sql_class.h:
- Added THD::binlog_warning_flags (see sql_class.cc for explanation).
- Made decide_logging_format() and reset_for_next_command() member
functions of THD (instead of standalone functions). This was needed
for two reasons: (1) the functions need to access the private member
THD::binlog_warning_flags; (2) the purpose of these functions is to
update the staet of a THD object, so from an object-oriented point
of view they should be member functions.
- Encapsulated current_stmt_binlog_row_based, so it is now private and
can only be accessed from a member function. Also changed the
data type to an enumeration instead of a bool.
- Removed MYSQL_QUERY_TYPE, because it was equivalent to
STMT_QUERY_TYPE anyways.
- When reset_current_stmt_binlog_row_based was called from the
ndb_binlog thread, it would behave as a no-op. This special
case has been removed, and the behavior of
reset_current_stmt_binlog_row_based does not depend on which thread
calls it any more. The special case did not serve any purpose,
since the ndb binlog thread did not take the
current_stmt_binlog_row_based flag into account anyways.
sql/sql_delete.cc:
- Moved logic for setting row format for DELETE..LIMIT away from
mysql_prepare_delete.
(Instead, we mark the statement as unsafe at parse time (sql_yacc.yy)
and rely on decide_logging_format() (sql_class.cc) to set row format.)
This is part of the fix for BUG#45831.
- Use member function to read current_stmt_binlog_row_based.
sql/sql_insert.cc:
- Removed unnecessary calls to thd->lex->set_stmt_unsafe() and
thd->set_current_stmt_binlog_row_based_if_mixed() from
handle_delayed_insert(). The calls are unnecessary because they
have already been made; they were made in the constructor of
the `di' object.
- Since decide_logging_format() is now a member function of THD, code
that calls decide_logging_format() had to be updated.
- Added DBUG_ENTER call, to be able to trace when set_stmt_unsafe is
called.
- Moved call to set_stmt_unsafe() for INSERT..SELECT..LIMIT away from
mysql_insert_select_prepare() (and into decide_logging_format).
This is part of the fix for BUG#45831.
- Use member function to read current_stmt_binlog_row_based.
sql/sql_lex.h:
- Added the flag BINLOG_STMT_FLAG_ROW_INJECTION to enum_binlog_stmt_flag.
This was necessary so that a statement can identify itself as a row
injection.
- Added appropriate setter and getter functions for the new flag.
- Added or clarified some comments.
- Added DBUG_ENTER()
sql/sql_load.cc:
Use member function to read current_stmt_binlog_row_based.
sql/sql_parse.cc:
- Made mysql_reset_thd_for_next_command() clear thd->binlog_warning_flags.
- Since thd->binlog_warning_flags is private, it must be set in a
member function of THD. Hence, moved the body of
mysql_reset_thd_for_next_command() to the new member function
THD::reset_thd_for_next_command(), and made
mysql_reset_thd_for_next_command() call
THD::reset_thd_for_next_command().
- Removed confusing comment.
- Use member function to read current_stmt_binlog_row_based.
sql/sql_repl.cc:
Use member function to read current_stmt_binlog_row_based.
sql/sql_table.cc:
Use member function to read current_stmt_binlog_row_based.
sql/sql_udf.cc:
Use member function to read current_stmt_binlog_row_based.
sql/sql_update.cc:
Moved logic for setting row format for UPDATE..LIMIT away from
mysql_prepare_update.
(Instead, we mark the statement as unsafe at parse time (sql_yacc.yy)
and rely on decide_logging_format() (sql_class.cc) to set row format.)
This is part of the fix for BUG#45831.
sql/sql_yacc.yy:
Made INSERT DELAYED, INSERT..SELECT..LIMIT, UPDATE..LIMIT, and
DELETE..LIMIT mark themselves as unsafe at parse time (instead
of at execution time).
This is part of the fixes BUG#45831 and BUG#45825.
storage/example/ha_example.cc:
Made exampledb accept inserts. This was needed by the new test case
rpl_ndb_binlog_format_errors, because it needs an engine that
is statement-only (and accepts inserts).
storage/example/ha_example.h:
Made exampledb a statement-only engine instead of a row-only engine.
No existing test relied exampledb's row-only capabilities. The new
test case rpl_ndb_binlog_format_errors needs an engine that is
statement-only.
storage/innobase/handler/ha_innodb.cc:
- Changed error error code and message given by innodb when
binlog_format=STATEMENT and transaction isolation level is
READ COMMITTED or READ UNCOMMITTED.
- While I was here, also simplified the condition for
checking when to give the error.
Mysql server crashes because unsafe statements warning is wrongly elevated to error,
which is set the error status of Diagnostics_area of the thread in THD::binlog_query().
Yet the caller believes that binary logging shouldn't touch the status, so it will
set the status also later by my_ok(), my_error() or my_message() seperately
according to the execution result of the statement or transaction.
But the status of Diagnostics_area of the thread is allowed to set only once.
Fixed to clear the error wrongly set by binary logging, but keep the warning message.
mysql-test/suite/binlog/r/binlog_stm_ps.result:
Change unsafe warning to NOTE level
mysql-test/suite/binlog/r/binlog_unsafe.result:
Test case result for unsafe statements to ensure mysql sever don't crash
mysql-test/suite/binlog/t/binlog_unsafe.test:
Test case for unsafe statements to ensure mysql sever don't crash
mysql-test/suite/rpl/r/rpl_skip_error.result:
Change unsafe warning to NOTE level
mysql-test/suite/rpl/r/rpl_stm_loadfile.result:
Change unsafe warning to NOTE level
mysql-test/suite/rpl/r/rpl_udf.result:
Change unsafe warning to NOTE level
sql/sql_class.cc:
the error status of the thread is cleared When a warning is elevated to an error
because of unsafe warning of binary log.
When binlog_format is STATEMENT and the statement is unsafe before,
the unsafe warning/error message was issued without checking
whether the SQL_LOG_BIN was turned on or not.
Fixed with adding a sql_log_bin_toplevel flag in THD to check
whether SQL_LOG_BIN is ON in current session whatever the current is in sp or not.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Test case result for unsafe warning/error message
mysql-test/suite/binlog/t/binlog_unsafe.test:
Test case for unsafe message warning/error
sql/set_var.cc:
Adding a function set_option_log_bin_bit() which specailly handles to
the change of SQL_LOG_BIN bit in order to set sql_log_bin_toplevel
according to SQL_LOG_BIN current value at the same time.
sql/sql_class.cc:
Initialize the flag sql_log_bin_toplevel in THD::init(),
and add the condition to check whether unsafe ror message was issued.
sql/sql_class.h:
Add a sql_log_bin_toplevel flag in THD to indicate whether the toplevel SQL_LOG_BIN is
The problem is that a unfiltered user query was being passed as
the format string parameter of sql_print_warning which later
performs printf-like formatting, leading to crashes if the user
query contains formatting instructions (ie: %s). Also, it was
using THD::query as the source of the user query, but this
variable is not meaningful in some situations -- in a delayed
insert, it points to the table name.
The solution is to pass the user query as a parameter for the
format string and use the function parameter query_arg as the
source of the user query.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Add test case result for Bug#42634
mysql-test/suite/binlog/t/binlog_unsafe.test:
Add test case for Bug#42634
sql/sql_class.cc:
Don't pass the user query as a format string.
into stella.local:/home2/mydev/mysql-5.1-axmrg
mysql-test/r/federated.result:
Auto merged
mysql-test/t/federated.test:
Auto merged
sql/sql_delete.cc:
Auto merged
sql/sql_parse.cc:
Auto merged
sql/sql_update.cc:
Auto merged
storage/federated/ha_federated.cc:
Auto merged
mysql-test/suite/binlog/r/binlog_unsafe.result:
Manual merge
mysql-test/suite/binlog/t/binlog_unsafe.test:
Manual merge
binlog_format=mixed
Statement-based replication of DELETE ... LIMIT, UPDATE ... LIMIT,
INSERT ... SELECT ... LIMIT is not safe as order of rows is not
defined.
With this fix, we issue a warning that this statement is not safe to
replicate in statement mode, or go to row-based mode in mixed mode.
Note that we may consider a statement as safe if ORDER BY primary_key
is present. However it may confuse users to see very similiar statements
replicated differently.
Note 2: regular UPDATE statement (w/o LIMIT) is unsafe as well, but
this patch doesn't address this issue. See comment from Kristian
posted 18 Mar 10:55.
mysql-test/suite/binlog/r/binlog_stm_ps.result:
Updated a test case according to fix for BUG#34768:
INSERT ... SELECT ... LIMIT is now replicated in row mode.
mysql-test/suite/binlog/r/binlog_unsafe.result:
A test case for BUG#34768.
mysql-test/suite/binlog/t/binlog_unsafe.test:
A test case for BUG#34768.
sql/sql_delete.cc:
Statement-based replication of DELETE ... LIMIT is not safe as order of
rows is not defined, so in mixed mode we go to row-based.
sql/sql_insert.cc:
Statement-based replication of INSERT ... SELECT ... LIMIT is not safe
as order of rows is not defined, so in mixed mode we go to row-based.
sql/sql_update.cc:
Statement-based replication of UPDATE ... LIMIT is not safe as order of
rows is not defined, so in mixed mode we go to row-based.
safe.
Fix: Move sql_mode: from the section of the test where safe variables are
tested, to the section where unsafe variables are tested.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Updated result file of modified test.
Problem: in mixed and statement mode, a query that refers to a
system variable will use the slave's value when replayed on
slave. So if the value of a system variable is inserted into a
table, the slave will differ from the master.
Fix: mark statements that refer to a system variable as "unsafe",
meaning they will be replicated by row in mixed mode and produce a warning
in statement mode. There are some exceptions: some variables are actually
replicated. Those should *not* be marked as unsafe.
BUG#34732: mysqlbinlog does not print default values for auto_increment variables
Problem: mysqlbinlog does not print default values for some variables,
including auto_increment_increment and others. So if a client executing
the output of mysqlbinlog has different default values, replication will
be wrong.
Fix: Always print default values for all variables that are replicated.
I need to fix the two bugs at the same time, because the test cases would
fail if I only fixed one of them.
include/m_ctype.h:
Added definition of ILLEGAL_CHARSET_INFO_NUMBER. We just need a symbol
for a number that will never be used by any charset. ~0U should be safe
since charset numbers are sequential, starting from 0.
mysql-test/include/commit.inc:
Upated test to avoid making statements unsafe.
mysql-test/r/commit_1innodb.result:
Updated test needs updated result file.
mysql-test/r/mysqlbinlog.result:
Updated result file.
mysql-test/r/mysqlbinlog2.result:
Updated result file.
mysql-test/r/user_var-binlog.result:
Updated result file.
mysql-test/suite/binlog/r/binlog_base64_flag.result:
Updated result file.
mysql-test/suite/binlog/r/binlog_stm_ctype_ucs.result:
Updated result file.
mysql-test/suite/binlog/r/binlog_unsafe.result:
Modified test file needs modified result file.
mysql-test/suite/binlog/t/binlog_base64_flag.test:
Need to filter out pseudo_thread_id from result since it is
nondeterministic.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Add tests that using variables is unsafe. The 'CREATE VIEW' tests didn't
make sense, so I removed them. SHOW WARNINGS is not necessary either,
because we get warnings for each statement in the result file.
mysql-test/suite/rpl/r/rpl_row_mysqlbinlog.result:
Updated result file.
mysql-test/suite/rpl/r/rpl_skip_error.result:
Updated result file.
mysql-test/suite/rpl/t/rpl_skip_error.test:
The test used @@server_id, which is not safe to replicate, so it would
have given a warning. The way it used @@server_id was hackish (issue a
query on master that removes rows only on master), so I replaced it by a
more robust way to do the same thing (connect to slave and insert the
rows only there).
Also clarified what the test case does.
mysql-test/t/mysqlbinlog2.test:
Use --short-form instead of manually filtering out nondeterministic stuff
from mysqlbinlog (because we added the nondeterministic @@pseudo_thread_id
to the output).
sql/item_func.cc:
Added method of Item_func_get_system_var that indicates whether the given
system variable will be written to the binlog or not.
sql/item_func.h:
Added method of Item_func_get_system_var that indicates whether the given
system variable will be written to the binlog or not.
sql/log_event.cc:
- auto_increment_offset was not written to the binlog if
auto_increment_increment=1
- mysqlbinlog did not output default values for some variables
(BUG#34732). In st_print_event_info, we remember for each variable whether
it has been printed or not. This is achieved in different ways for
different variables:
- For auto_increment_*, lc_time_names, charset_database_number,
we set the default values in st_print_event_info to something
illegal, so that it will look like they have changed the first time
they are seen.
- For charset, sql_mode, pseudo_thread_id, we add a flag to
st_print_event_info which indicates whether the variable has been
printed.
- Since pseudo_thread_id is now printed more often, and its value is
not guaranteed to be constant across different runs of the same
test script, I replaced it by a constant if --short-form is used.
- Moved st_print_event_info constructor from log_event.h to log_event.cc,
since it now depends on ILLEGAL_CHARSET_NUMBER, which is defined in
m_ctype.h, which is better to include from a .cc file than from a header
file.
sql/log_event.h:
Added fields to st_print_event_info that indicate whether some of the
variables have been written or not. Since the initialization of
charset_database_number now depends on ILLEGAL_CHARSET_INFO_NUMBER, which
is defined in a header file, which we'd better not include from this
header file -- I moved the constructor from here to log_event.cc.
sql/set_var.cc:
System variables now have a flag binlog_status, which indicates if they
are written to the binlog. If nothing is specified, all variables are
marked as not written to the binlog (NOT_IN_BINLOG) when created. In this
file, the variables that are written to the binlog are marked with
SESSION_VARIABLE_IN_BINLOG.
sql/set_var.h:
Added flag binlog_status to class sys_var. Added a getter and a
constructor parameter that sets it.
Since I had to change sys_var_thd_enum constructor anyways, I simplified
it to use default values of arguments instead of three copies of the
constructor.
sql/sql_yacc.yy:
Mark statements that refer to a system variable as "unsafe",
meaning they will be replicated by row in mixed mode. Added comment to
explain strange piece of code just above.
mysql-test/include/diff_tables.inc:
New auxiliary test file that tests whether two tables (possibly one on
master and one on slave) differ.
mysql-test/suite/rpl/r/rpl_variables.result:
New test case needs new result file.
mysql-test/suite/rpl/r/rpl_variables_stm.result:
New test file needs new result file.
mysql-test/suite/rpl/t/rpl_variables.test:
Test that INSERT of @@variables is replicated correctly (by switching to
row-based mode).
mysql-test/suite/rpl/t/rpl_variables_stm.test:
Test that replication of @@variables which are replicated explicitly works
as expected in statement mode (without giving warnings).