ChangeSet@1.2571, 2008-04-08 12:30:06+02:00, vvaintroub@wva. +122 -0
Bug#32082 : definition of VOID in my_global.h conflicts with Windows
SDK headers
VOID macro is now removed. Its usage is replaced with void cast.
In some cases, where cast does not make much sense (pthread_*, printf,
hash_delete, my_seek), cast is ommited.
This is the non-ndb part of the patch.
The return value of mysql_bin_log.write was ignored by most callers,
which may lead to inconsistent on master and slave if the transaction
was committed while the binlog was not correctly written. If
my_error() is call in mysql_bin_log.write, this could also lead to
assertion issue if my_ok() or my_error() is called after.
This fixed the problem by let the caller to check and handle the
return value of mysql_bin_log.write. This patch only adresses the
simple cases.
port from mysql-next (5.4) to mysql-next-mr-bugfixing (5.5/5.6?)
2755 Konstantin Osipov 2008-11-27
Bug#32115 will remove the pre-requisite to initialize LEX to open tables.
This dependency was added in 5.1 and was supposed to be removed in 6.0.
Remove asserts and initialization of LEX in places where we don't deal
with partitioned tables.
------------------------------------------------------------
revno: 2597.4.17
revision-id: sp1r-davi@mysql.com/endora.local-20080328174753-24337
parent: sp1r-anozdrin/alik@quad.opbmk-20080328140038-16479
committer: davi@mysql.com/endora.local
timestamp: Fri 2008-03-28 14:47:53 -0300
message:
Bug#15192 "fatal errors" are caught by handlers in stored procedures
The problem is that fatal errors (e.g.: out of memory) were being
caught by stored procedure exception handlers which could cause
the execution to not be stopped due to a continue handler.
The solution is to not call any exception handler if the error is
fatal and send the fatal error to the client.
------------------------------------------------------------
revno: 2630.39.3
revision-id: davi.arnaut@sun.com-20081210215359-i876m4zgc2d6rzs3
parent: kostja@sun.com-20081208222938-9es7wl61moli71ht
committer: Davi Arnaut <Davi.Arnaut@Sun.COM>
branch nick: 36649-6.0
timestamp: Wed 2008-12-10 19:53:59 -0200
message:
Bug#36649: Condition area is not properly cleaned up after stored routine invocation
The problem is that the diagnostics area of a trigger is not
isolated from the area of the statement that caused the trigger
invocation. In MySQL terms, it means that warnings generated
during the execution of the trigger are not removed from the
"warning area" at the end of the execution.
Before this fix, the rules for MySQL message list life cycle (see
manual entry for SHOW WARNINGS) did not apply to statements
inside stored programs:
- The manual says that the list of messages is cleared by a
statement that uses a table (any table). However, such
statement, if run inside a stored program did not clear the
message list.
- The manual says that the list is cleared by a statement that
generates a new error or a warning, but this was not the case
with stored program statements either and is changed to be the
case as well.
In other words, after this fix, a statement has the same effect
on the message list regardless of whether it's executed inside a
stored program/sub-statement or not.
This introduces an incompatible change:
- before this fix, a, e.g. statement inside a trigger could
never clear the global warning list
- after this fix, a trigger that generates a warning or uses a
table, clears the global warning list
- however, when we leave a trigger or a function, the caller's
warning information is restored (see more on this below).
This change is not backward compatible as it is intended to make
MySQL behavior similar to the SQL standard behavior:
A stored function or trigger will get its own "warning area" (or,
in standard terminology, diagnostics area). At the beginning of
the stored function or trigger, all messages from the caller area
will be copied to the area of the trigger. During execution, the
message list will be cleared according to the MySQL rules
described on the manual (SHOW WARNINGS entry). At the end of the
function/trigger, the "warning area" will be destroyed along with
all warnings it contains, except that if the last statement of
the function/trigger generated messages, these are copied into
the "warning area" of the caller.
Consequently, statements that use a table or generate a warning
*will* clear warnings inside the trigger, but that will have no
effect to the warning list of the calling (outer) statement.
Non-transactional updates that take place inside a transaction present problems
for logging because they are visible to other clients before the transaction
is committed, and they are not rolled back even if the transaction is rolled
back. It is not always possible to log correctly in statement format when both
transactional and non-transactional tables are used in the same transaction.
In the current patch, we ensure that such scenario is completely safe under the
ROW and MIXED modes.
Conflicts
=========
Text conflict in .bzr-mysql/default.conf
Text conflict in libmysqld/CMakeLists.txt
Text conflict in libmysqld/Makefile.am
Text conflict in mysql-test/collections/default.experimental
Text conflict in mysql-test/extra/rpl_tests/rpl_row_sp006.test
Text conflict in mysql-test/suite/binlog/r/binlog_tmp_table.result
Text conflict in mysql-test/suite/rpl/r/rpl_loaddata.result
Text conflict in mysql-test/suite/rpl/r/rpl_loaddata_fatal.result
Text conflict in mysql-test/suite/rpl/r/rpl_row_create_table.result
Text conflict in mysql-test/suite/rpl/r/rpl_row_sp006_InnoDB.result
Text conflict in mysql-test/suite/rpl/r/rpl_stm_log.result
Text conflict in mysql-test/suite/rpl_ndb/r/rpl_ndb_circular_simplex.result
Text conflict in mysql-test/suite/rpl_ndb/r/rpl_ndb_sp006.result
Text conflict in mysql-test/t/mysqlbinlog.test
Text conflict in sql/CMakeLists.txt
Text conflict in sql/Makefile.am
Text conflict in sql/log_event_old.cc
Text conflict in sql/rpl_rli.cc
Text conflict in sql/slave.cc
Text conflict in sql/sql_binlog.cc
Text conflict in sql/sql_lex.h
21 conflicts encountered.
NOTE
====
mysql-5.1-rpl-merge has been made a mirror of mysql-next-mr:
- "mysql-5.1-rpl-merge$ bzr pull ../mysql-next-mr"
This is the first cset (merge/...) committed after pulling
from mysql-next-mr.
2630.39.1, 2630.28.29, 2630.34.3, 2630.34.2, 2630.34.1, 2630.29.29,
2630.29.28, 2630.31.1, 2630.28.13, 2630.28.10, 2617.23.14 and
some other minor revisions.
This patch implements:
WL#4264 "Backup: Stabilize Service Interface" -- all the
server prerequisites except si_objects.{h,cc} themselves (they can
be just copied over, when needed).
WL#4435: Support OUT-parameters in prepared statements.
(and all issues in the initial patches for these two
tasks, that were discovered in pushbuild and during testing).
Bug#39519: mysql_stmt_close() should flush all data
associated with the statement.
After execution of a prepared statement, send OUT parameters of the invoked
stored procedure, if any, to the client.
When using the binary protocol, send the parameters in an additional result
set over the wire. When using the text protocol, assign out parameters to
the user variables from the CALL(@var1, @var2, ...) specification.
The following refactoring has been made:
- Protocol::send_fields() was renamed to Protocol::send_result_set_metadata();
- A new Protocol::send_result_set_row() was introduced to incapsulate
common functionality for sending row data.
- Signature of Protocol::prepare_for_send() was changed: this operation
does not need a list of items, the number of items is fully sufficient.
The following backward incompatible changes have been made:
- CLIENT_MULTI_RESULTS is now enabled by default in the client;
- CLIENT_PS_MULTI_RESUTLS is now enabled by default in the client.
SP variables
A function call may end without throwing an error or without setting
the return value. This can happen when e.g. an error occurs while
calculating the return value.
Fixed by setting the value to NULL when error occurs during evaluation
of an expression.
The flag EXTRA_ACL is used in conjugation with our access checks, yet it is
not clear what impact this flag has.
This is a code clean up which replaces use of EXTRA_ACL with an explicit
function parameter.
The patch also fixes privilege checks for:
- SHOW CREATE TABLE: The new privilege requirement is any privilege on
the table-level.
- CHECKSUM TABLE: Requires SELECT on the table level.
- SHOW CREATE VIEW: Requires SHOW_VIEW and SELECT on the table level
(just as the manual claims)
- SHOW INDEX: Requires any privilege on any column combination.
----------------------------------------------------------
revno: 2630.13.6
committer: Konstantin Osipov <konstantin@mysql.com>
branch nick: mysql-6.0-3288
timestamp: Fri 2008-07-11 20:22:44 +0400
message:
WL#3288, step 1: ensure that the SQL layer always closes an open
cursor (rnd or index read) before closing a handler.
Implemented the server infrastructure for the fix:
1. Added a function LEX_STRING *thd_query_string(THD) to return
a LEX_STRING structure instead of char *.
This is the function that must be called in innodb instead of
thd_query()
2. Did some encapsulation in THD : aggregated thd_query and
thd_query_length into a LEX_STRING and made accessor and mutator
methods for easy code updating.
3. Updated the server code to use the new methods where applicable.
"have_profiling"
1) Renamed have_community_features server system variable to
have_profiling.
2) Removed eable-community-features configure option and
ENABLE_COMMUNITY_FEATURES macro.
3) Removed COMMUNITY_SERVER macro and replaced its usage by
ENABLED_PROFILING.
Only --enable-profiling is now needed to enable profiling.
It was the only existing "community feature", so there was
no need for both configure options.
Using --enable-community-features will give a warning message
since it no longer exists.
files
NOTE: this is the backport to next-mr.
SHOW BINLOG EVENTS does not work with relay log files. If issuing
"SHOW BINLOG EVENTS IN 'relay-log.000001'" in a non-empty relay
log file (relay-log.000001), mysql reports empty set.
This patch addresses this issue by extending the SHOW command
with RELAYLOG. Events in relay log files can now be inspected by
issuing SHOW RELAYLOG EVENTS [IN 'log_name'] [FROM pos] [LIMIT
[offset,] row_count].
bzr branch mysql-5.1-performance-version mysql-trunk # Summit
cd mysql-trunk
bzr merge mysql-5.1-innodb_plugin # which is 5.1 + Innodb plugin
bzr rm innobase # remove the builtin
Next step: build, test fixes.
an assertion in a debug build.
The reason is that the C API doesn't support multiple result sets for prepared
statements and attempting to execute a stored routine which returns multiple result
sets sometimes lead to a network error. The network error sets the diagnostic area
prematurely which later leads to the assert when an attempt is made to set a second
server state.
This patch fixes the issue by changing the scope of the error code returned by
sp_instr_stmt::execute() to include any error which happened during the execution.
To assure that Diagnostic_area::is_sent really mean that the message was sent all
network related functions are checked for return status.
procedures causes crashes!
The problem of that bugreport was mostly fixed by the
patch for bug 38691.
However, attached test case focused on another crash or
valgrind warning problem: SHOW PROCESSLIST query accesses
freed memory of SP instruction that run in a parallel
connection.
Changes of thd->query/thd->query_length in dangerous
places have been guarded with the per-thread
LOCK_thd_data mutex (the THD::LOCK_delete mutex has been
renamed to THD::LOCK_thd_data).
This is a post-push fix addressing review requests and
problems with extra warnings.
Problem 1: The sub-statement where an unsafe warning was detected was
printed as part of the warning. This was ok for statements that
were unsafe due to, e.g., calls to UUID(), but did not make
sense for statements that were unsafe because there was more than
one autoincrement column (unsafeness in this case comes from the
combination of several sub-statements).
Fix 1: Instead of printing the sub-statement, print an explanation
of why the statement is unsafe.
Problem 2:
When a recursive construct (i.e., stored proceure, stored
function, trigger, view, prepared statement) contained several
sub-statements, and at least one of them was unsafe, there would be
one unsafeness warning per sub-statement - even for safe
sub-statements.
Fix 2:
Ensure that each type of warning is printed at most once, by
remembering throughout the execution of the statement which types
of warnings have been printed.
General overview:
The logic for switching to row format when binlog_format=MIXED had
numerous flaws. The underlying problem was the lack of a consistent
architecture.
General purpose of this changeset:
This changeset introduces an architecture for switching to row format
when binlog_format=MIXED. It enforces the architecture where it has
to. It leaves some bugs to be fixed later. It adds extensive tests to
verify that unsafe statements work as expected and that appropriate
errors are produced by problems with the selection of binlog format.
It was not practical to split this into smaller pieces of work.
Problem 1:
To determine the logging mode, the code has to take several parameters
into account (namely: (1) the value of binlog_format; (2) the
capabilities of the engines; (3) the type of the current statement:
normal, unsafe, or row injection). These parameters may conflict in
several ways, namely:
- binlog_format=STATEMENT for a row injection
- binlog_format=STATEMENT for an unsafe statement
- binlog_format=STATEMENT for an engine only supporting row logging
- binlog_format=ROW for an engine only supporting statement logging
- statement is unsafe and engine does not support row logging
- row injection in a table that does not support statement logging
- statement modifies one table that does not support row logging and
one that does not support statement logging
Several of these conflicts were not detected, or were detected with
an inappropriate error message. The problem of BUG#39934 was that no
appropriate error message was written for the case when an engine
only supporting row logging executed a row injection with
binlog_format=ROW. However, all above cases must be handled.
Fix 1:
Introduce new error codes (sql/share/errmsg.txt). Ensure that all
conditions are detected and handled in decide_logging_format()
Problem 2:
The binlog format shall be determined once per statement, in
decide_logging_format(). It shall not be changed before or after that.
Before decide_logging_format() is called, all information necessary to
determine the logging format must be available. This principle ensures
that all unsafe statements are handled in a consistent way.
However, this principle is not followed:
thd->set_current_stmt_binlog_row_based_if_mixed() is called in several
places, including from code executing UPDATE..LIMIT,
INSERT..SELECT..LIMIT, DELETE..LIMIT, INSERT DELAYED, and
SET @@binlog_format. After Problem 1 was fixed, that caused
inconsistencies where these unsafe statements would not print the
appropriate warnings or errors for some of the conflicts.
Fix 2:
Remove calls to THD::set_current_stmt_binlog_row_based_if_mixed() from
code executed after decide_logging_format(). Compensate by calling the
set_current_stmt_unsafe() at parse time. This way, all unsafe statements
are detected by decide_logging_format().
Problem 3:
INSERT DELAYED is not unsafe: it is logged in statement format even if
binlog_format=MIXED, and no warning is printed even if
binlog_format=STATEMENT. This is BUG#45825.
Fix 3:
Made INSERT DELAYED set itself to unsafe at parse time. This allows
decide_logging_format() to detect that a warning should be printed or
the binlog_format changed.
Problem 4:
LIMIT clause were not marked as unsafe when executed inside stored
functions/triggers/views/prepared statements. This is
BUG#45785.
Fix 4:
Make statements containing the LIMIT clause marked as unsafe at
parse time, instead of at execution time. This allows propagating
unsafe-ness to the view.