Problem was that trx_sys->mutex was acquired to print trx info
even when we already hold trx_sys->mutex. Fixed similarly as
in InnoDB, i.e. with wsrep_trx_print_locking() function that
does not acquire trx_sys->mutex.
Introduced a new wsrep_trx_print_locking() which may be called
under lock_sys->mutex if the trx has locks.
Signed-off-by: Sachin Setiya <sachinsetia1001@gmail.com>
In the 10.1 InnoDB Plugin, a call os_event_free(buf_flush_event) was
misplaced. The event could be signalled by rollback of resurrected
transactions while shutdown was in progress. This bug was caught
by cmake -DWITH_ASAN testing. This call was only present in the
10.1 InnoDB Plugin, not in other versions, or in XtraDB.
That said, the bug affects all InnoDB versions. Shutdown assumes the
cessation of any page-dirtying activity, including the activity of
the background rollback thread. InnoDB only waited for the background
rollback to finish as part of a slow shutdown (innodb_fast_shutdown=0).
The default is a clean shutdown (innodb_fast_shutdown=1). In a scenario
where InnoDB is killed, restarted, and shut down soon enough, the data
files could become corrupted.
logs_empty_and_mark_files_at_shutdown(): Wait for the
rollback to finish, except if innodb_fast_shutdown=2
(crash-like shutdown) was requested.
trx_rollback_or_clean_recovered(): Before choosing the next
recovered transaction to roll back, terminate early if non-slow
shutdown was initiated. Roll back everything on slow shutdown
(innodb_fast_shutdown=0).
srv_innodb_monitor_mutex: Declare as static, because the mutex
is only used within one module.
After each call to os_event_free(), ensure that the freed event
is not reachable via global variables, by setting the relevant
variables to NULL.
Also, implement MDEV-11027 a little differently from 5.5:
recv_sys_t::report(ib_time_t): Determine whether progress should
be reported.
recv_apply_hashed_log_recs(): Rename the parameter to last_batch.
Provide more useful progress reporting of crash recovery.
recv_sys_t::progress_time: The time of the last report.
recv_scan_print_counter: Remove.
log_group_read_log_seg(): After after each I/O request,
report progress if needed.
recv_apply_hashed_log_recs(): At the start of each batch,
if there are pages to be recovered, issue a message.
dir_per_db_rename_to_nenexisting_schema: mysqltest fails with no output
percona_kill_idle_trx_tokudb: MariaDB doesn't support kill_idle_trx var
for all SE.
my_readline can fail due to missing file. Make my_readline report this
condition separately so that we can catch it and report an appropriate
error message to the user.
The function posix_fallocate() as well as the Linux system call
fallocate() can return EINTR when the operation was interrupted
by a signal. In that case, keep retrying the operation, except
if InnoDB shutdown has been initiated.
The function posix_fallocate() as well as the Linux system call
fallocate() can return EINTR when the operation was interrupted
by a signal. In that case, keep retrying the operation, except
if InnoDB shutdown has been initiated.
modified: storage/connect/ha_connect.cc
Add conditional SE exception support
modified: storage/connect/json.cpp
modified: storage/connect/plgdbutl.cpp
Change %p in %x in some sprintf functions.
This to avoid some compiler warnings.
modified: storage/connect/tabwmi.cpp
modified: storage/connect/tabxml.cpp
modified: storage/connect/value.h
Add JavaWrappers.jar to the class path
modified: storage/connect/jdbconn.cpp
Fix wrong declare (char *buf[256]; --> char buf[256];)
modified: storage/connect/xindex.cpp
On FreeBSD liblz4 is installed in /usr/local/lib.
Groonga uses pkg_check_modules to check for liblz4 (that is, pkg-config),
and then it used to set for libgroonga.a
link_directories({$LIBLZ4_LIBRARY_DIRS})
target_link_libraries(... ${LIBLZ4_LIBRARIES})
Now groonga is a static library, linked into ha_mroonga.so. CMake won't
link dynamic liblz4.so into libgroonga.a, instead it'll pass it as a
dependency and will link it into ha_mroonga.so. Fine so far. But it will
not pass link_directories from the static library as a dependency,
so ha_mroonga.so won't find liblz4.so
As suggested on cmake mailing list (e.g.
here: http://public.kitware.com/pipermail/cmake/2011-November/047468.html)
we switch to use the full path to liblz4.so, instead of the -l/-L pair.
- Removed not used variables
- Added __attribute__()
- Added static to some local functions
(gcc 5.4 gives a warning for external functions without an external definition)
it was race condition prone. instead use either a pair of my_delete()
calls with already resolved paths, or a safe high-level function
my_handler_delete_with_symlink(), like MyISAM and Aria already do.
TOCTOU bug. The path is checked to be valid, symlinks are resolved.
Then the resolved path is opened. Between the check and the open,
there's a window when one can replace some path component with a
symlink, bypassing validity checks.
Fix: after we resolved all symlinks in the path, don't allow open()
to resolve symlinks, there should be none.
Compared to the old MyISAM/Aria code:
* fastpath. Opening of not-symlinked files is just one open(),
no fn_format() and lstat() anymore.
* opening of symlinked tables doesn't do fn_format() and lstat() either.
it also doesn't to realpath() (which was lstat-ing every path
component), instead if opens every path component with O_PATH.
* share->data_file_name stores realpath(path) not readlink(path). So,
SHOW CREATE TABLE needs to do lstat/readlink() now (see ::info()),
and certain error messages (cannot open file "XXX") show the real
file path with all symlinks resolved.
fil_extend_space_to_desired_size(): Use a proper type cast when
computing start_offset for the posix_fallocate() call on 32-bit systems
(where sizeof(ulint) < sizeof(os_offset_t)). This could affect 32-bit
systems when extending files that are at least 4 MiB long.
This bug existed in MariaDB 10.0 before MDEV-11520. In MariaDB 10.1
it had been fixed in MDEV-11556.
a large memory buffer on Windows
fil_extend_space_to_desired_size(), os_file_set_size(): Use calloc()
for memory allocation, and handle failures. Properly check the return
status of posix_fallocate(), and pass the correct arguments to
posix_fallocate().
On Windows, instead of extending the file by at most 1 megabyte at a time,
write a zero-filled page at the end of the file.
According to the Microsoft blog post
https://blogs.msdn.microsoft.com/oldnewthing/20110922-00/?p=9573
this will physically extend the file by writing zero bytes.
(InnoDB never uses DeviceIoControl() to set the file sparse.)
I tested that the file extension works properly with a multi-file
system tablespace, both with --innodb-use-fallocate and
--skip-innodb-use-fallocate (the default):
./mtr \
--mysqld=--innodb-use-fallocate \
--mysqld=--innodb-autoextend-increment=1 \
--mysqld=--innodb-data-file-path='ibdata1:5M;ibdata2:5M:autoextend' \
--parallel=auto --force --retry=0 --suite=innodb &
ls -lsh mysql-test/var/*/mysqld.1/data/ibdata2
(several samples while running the test)
Before the MDEV-11520 fixes, fil_extend_space_to_desired_size()
in MariaDB Server 5.5 incorrectly passed the desired file size as the
third argument to posix_fallocate(), even though the length of the
extension should have been passed. This looks like a regression
that was introduced in the 5.5 version of MDEV-5746.
Remove the unused variable desired_size.
Also, correct the expression for the posix_fallocate() start_offset,
and actually test that it works with a multi-file system tablespace.
Before MDEV-11520, the expression was wrong in both innodb_plugin and
xtradb, in different ways.
The start_offset formula was tested with the following:
./mtr --big-test --mysqld=--innodb-use-fallocate \
--mysqld=--innodb-data-file-path='ibdata1:5M;ibdata2:5M:autoextend' \
--parallel=auto --force --retry=0 --suite=innodb &
ls -lsh mysql-test/var/*/mysqld.1/data/ibdata2
a large memory buffer on Windows
fil_extend_space_to_desired_size(), os_file_set_size(): Use calloc()
for memory allocation, and handle failures. Properly check the return
status of posix_fallocate().
On Windows, instead of extending the file by at most 1 megabyte at a time,
write a zero-filled page at the end of the file.
According to the Microsoft blog post
https://blogs.msdn.microsoft.com/oldnewthing/20110922-00/?p=9573
this will physically extend the file by writing zero bytes.
(InnoDB never uses DeviceIoControl() to set the file sparse.)
For innodb_plugin, port the XtraDB fix for MySQL Bug#56433
(introducing fil_system->file_extend_mutex). The bug was
fixed differently in MySQL 5.6 (and MariaDB Server 10.0).
The function trx_purge_stop() was calling os_event_reset(purge_sys->event)
before calling rw_lock_x_lock(&purge_sys->latch). The os_event_set()
call in srv_purge_coordinator_suspend() is protected by that X-latch.
It would seem a good idea to consistently protect both os_event_set()
and os_event_reset() calls with a common mutex or rw-lock in those
cases where os_event_set() and os_event_reset() are used
like condition variables, tied to changes of shared state.
For each os_event_t, we try to document the mutex or rw-lock that is
being used. For some events, frequent calls to os_event_set() seem to
try to avoid hangs. Some events are never waited for infinitely, only
timed waits, and os_event_set() is used for early termination of these
waits.
os_aio_simulated_put_read_threads_to_sleep(): Define as a null macro
on other systems than Windows. TODO: remove this altogether and disable
innodb_use_native_aio on Windows.
os_aio_segment_wait_events[]: Initialize only if innodb_use_native_aio=0.