Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
And a new test for this bug.
mysql-test/r/rpl_loaddata.result:
Now, after CHANGE MASTER the coordinates of the I/O thread are the last ones of the SQL thread, so result update.
sql/sql_repl.cc:
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
2003-11-18 17:31:17 +01:00
|
|
|
slave stop;
|
|
|
|
drop table if exists t1,t2,t3,t4,t5,t6,t7,t8,t9;
|
|
|
|
reset master;
|
|
|
|
reset slave;
|
|
|
|
drop table if exists t1,t2,t3,t4,t5,t6,t7,t8,t9;
|
|
|
|
slave start;
|
|
|
|
select get_lock("a",5);
|
|
|
|
get_lock("a",5)
|
|
|
|
1
|
|
|
|
create table t1(n int);
|
2003-11-23 21:03:10 +02:00
|
|
|
insert into t1 values(1+get_lock("a",15)*0);
|
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
And a new test for this bug.
mysql-test/r/rpl_loaddata.result:
Now, after CHANGE MASTER the coordinates of the I/O thread are the last ones of the SQL thread, so result update.
sql/sql_repl.cc:
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
2003-11-18 17:31:17 +01:00
|
|
|
insert into t1 values(2);
|
|
|
|
stop slave;
|
|
|
|
select * from t1;
|
|
|
|
n
|
|
|
|
1
|
|
|
|
show slave status;
|
|
|
|
Master_Host Master_User Master_Port Connect_retry Master_Log_File Read_Master_Log_Pos Relay_Log_File Relay_Log_Pos Relay_Master_Log_File Slave_IO_Running Slave_SQL_Running Replicate_do_db Replicate_ignore_db Last_errno Last_error Skip_counter Exec_master_log_pos Relay_log_space
|
2003-11-23 21:03:10 +02:00
|
|
|
127.0.0.1 root MASTER_MYPORT 1 master-bin.001 273 slave-relay-bin.002 255 master-bin.001 No No 0 0 214 314
|
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
And a new test for this bug.
mysql-test/r/rpl_loaddata.result:
Now, after CHANGE MASTER the coordinates of the I/O thread are the last ones of the SQL thread, so result update.
sql/sql_repl.cc:
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
2003-11-18 17:31:17 +01:00
|
|
|
change master to master_user='root';
|
|
|
|
show slave status;
|
|
|
|
Master_Host Master_User Master_Port Connect_retry Master_Log_File Read_Master_Log_Pos Relay_Log_File Relay_Log_Pos Relay_Master_Log_File Slave_IO_Running Slave_SQL_Running Replicate_do_db Replicate_ignore_db Last_errno Last_error Skip_counter Exec_master_log_pos Relay_log_space
|
2003-11-23 21:03:10 +02:00
|
|
|
127.0.0.1 root MASTER_MYPORT 1 master-bin.001 214 slave-relay-bin.001 4 master-bin.001 No No 0 0 214 4
|
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
And a new test for this bug.
mysql-test/r/rpl_loaddata.result:
Now, after CHANGE MASTER the coordinates of the I/O thread are the last ones of the SQL thread, so result update.
sql/sql_repl.cc:
Fix for BUG#1870
"CHANGE MASTER makes SQL thread restart from coordinates of I/O thread".
So, in CHANGE MASTER:
when it seems reasonable that the user did not want to discontinue
its replication (i.e. when he is not specifying host or port or master_log_file
or master_log_pos; this will be documented), set the coordinates of the
I/O thread to those of the SQL thread. This way, the SQL thread will see
no discontinuity in the relay log (i.e. will skip no events), because
the I/O thread will fill the brand new relay log with the events which
are just after the position where the SQL thread had stopped
(before CHANGE MASTER was issued).
2003-11-18 17:31:17 +01:00
|
|
|
select release_lock("a");
|
|
|
|
release_lock("a")
|
|
|
|
1
|
|
|
|
start slave;
|
|
|
|
select * from t1;
|
|
|
|
n
|
|
|
|
1
|
|
|
|
2
|
|
|
|
drop table t1;
|